PLC Optical Splitter Owner’s Manual
- July 23, 2024
- Optical
Table of Contents
PLC Optical Splitter
Introduction
PLC Optical Splitter
- PLC (Planar Lightwave Circuits) splitters are developed using silica glass waveguide circuits and aligned fiber pigtails, integrated inside a miniature package.
- PLC splitters provide low-cost solutions for optical signal distribution, with a small form factor and superb reliability.
- The PLCs devices have 1×4, 1×8, 1×16, and 1×32 standard configurations, as well as customized structures of 2×4, 2×32, and 2×64.
- These products meet or exceed Telcordia GR-1209-CORE and GR-1221-CORE reliability qualification requirements.
Features
- Low insertion loss
- Various coupling ratio
- high return loss and excellent uniformity.
- Low Polarization dependent loss
- Environmental stable
- Operation wavelength: 1260mm to 1650nm
- Operating Temperature:-40°C to 85°C
Application
- FTTx systems
- Optical LAN, Metro, and WAN networks
- Passive optical networks
- CATV networks
Specification
Table 1 – 1xN PLC optical splitter
Parameters | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | 1×128 |
---|---|---|---|---|---|---|---|
Operating wavelength (nm) | 1260~ 1650 | ||||||
Fiber type | G657A or other request | ||||||
Insertion Loss (dB) (Max.) | 3.9 | 7.2 | 10.3 | 13.5 | 16.8 | 20.5 | 23.5 |
Uniformity(dB) (Max.) | 0.6 | 0.6 | 0.8 | 1.0 | 1.5 | 1.8 | 2.0 |
Return Loss(dB) (Min.) | 55 | 55 | 55 | 55 | 55 | 55 | 55 |
Temperature stability
(-40~ 85 °C)(dB) (Max.)
| ****
0.5
| ****
0.5
| ****
0.5
| ****
0.8
| ****
0.8
| ****
1.0
| ****
1.0
Polarization dependent loss
(dB)(Max.)
| ****
0.2
| ****
0.2
| ****
0.3
| ****
0.3
| ****
0.3
| ****
0.4
| ****
0.4
Wavelength Dependent Loss
(dB)(Max.)
| ****
0.5
| ****
0.5
| ****
0.5
| ****
0.8
| ****
0.8
| ****
0.8
| ****
1.2
Directivity (dB)(Min.)| 55
Operating Temperature (°C)| -40~ 85
Storage temperature(°C )| -40~ 85
Device package size (mm) (LxWxH)
0.25mm fiber
| ****
40x4x4
| ****
45x5x4
| ****
50x7x4
| ****
60x12x4
| ****
120x26x10
Micro Module Size (mm) (LxWxH) 0.9mm fiber| ****
55x7x4
| ****
60x12x4
| ****
80x20x6
| ****
100x40x6
| ****
120x50x12
Module Box Dimensions (mm) (LxWxH) 2.0mm fiber| ****
100x80x10
| ****
120x80x18
| ****
140x115x18
| ****
150x130x25
Note
- Specification without fiber optic connectors;
- Each connector will add a loss of 0.2dB.
Table 2 – 2xN PLC Optical Splitter
Parameters | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 | 2×128 |
---|---|---|---|---|---|---|---|
Operating wavelength (nm) | 1260~ 1650 | ||||||
Fiber type | G657A or other request | ||||||
Insertion Loss (dB) (Max.) | 4.2 | 7.5 | 10.6 | 13.9 | 17.2 | 20.8 | 23.8 |
Uniformity(dB) (Max.) | 0.8 | 1.0 | 1.2 | 1.5 | 1.8 | 2.0 | 2.0 |
Return Loss(dB) (Min.) | 55 | 55 | 55 | 55 | 55 | 55 | 55 |
Temperature stability
(-40~ 85 °C)(dB) (Max.)
| ****
0.6
| ****
0.6
| ****
0.6
| ****
0.8
| ****
1.0
| ****
1.0
| ****
1.0
Polarization dependent loss
(dB)(Max.)
| ****
0.2
| ****
0.2
| ****
0.3
| ****
0.3
| ****
0.4
| ****
0.4
| ****
0.4
Wavelength Dependent Loss
(dB)(Max.)
| ****
0.6
| ****
0.6
| ****
0.6
| ****
0.8
| ****
1.0
| ****
1.0
| ****
1.2
---|---|---|---|---|---|---|---
Directivity (dB)(Min.)| 55
Operating Temperature (°C)| -40~ 85
Storage temperature(°C )| -40~ 85
Device package size (mm) (LxWxH)
0.25mm fiber
| ****
50x4x4
| ****
50x?x4
| ****
60x12x4
| ****
120x26x10
Micro Module Size (mm) (LxWxH)
0.9mm fiber
| ****
55x?x4
| ****
60x?x4
| ****
60x12x4
| ****
80x20x6
| ****
100x40x6
| ****
120x50x12
Module Box Dimensions (mm) (LxWxH)
2.0mm fiber
| ****
100x80x10
| ****
120x80x18
| ****
140x115x18
| ****
150x130x25
Note
- Specification without fiber optic connectors;
- Each connector will add a loss of 0.2dB.