Optical ULTIMODE OPM-2 Multi Meter User Manual

June 9, 2024
Optical

Optical ULTIMODE OPM-2 Multi Meter

Optical-ULTIMODE-OPM-2-Multi-Meter-PRODUCT

Appearanceand Ports **

Optical-ULTIMODE-OPM-2-Multi-Meter-FIG
8**

  1. OPM port: connect to the fiber, test the optical power
  2. VFL port: connect to the fiber, find the fault point in short distance
  3. LED light: flashlight lighting
  4. Dust cover: cover to protect the optical port when no testing
  5. Display screen: display test results and other information
  6. Indicators: cable tracking light
  7. :Power key, turn on/off automatic shutdown function
  8. /VFL: turn on/off back light, turn on/off VFL
  9. RJ45/dB: turn on/off RJ45 sequence, switch absolute power display
  10. RJ45 network port: RJ45 sequence/tracking test
  11. PRESS button: press to take out the RJ45 sequence remote tester
  12. Remote tester: RJ45 cable sequence test
  13. λ: switch the test wavelength of the power meter
  14. LED key: turn on/off flash light
  15. REF key: set the current power as the reference power
  16. Micro USB: connect the power bank to supply power or charge

Power on/off and automatic shutdown

After pressing briefly , the meter will turn on and start the automatic shutdown function. The default automatic shutdown time is 10 minutes. If you want to cancel the function, press and hold the power key for two seconds, and the icon dis appears, the automatic shutdown will be cancelled.

Set Reference Optical Power

After power on, enter the interface of OPM, press REF to set the current power as the reference power, switch the relative optical power test (insertion losstest) and absolute power test. In the relative power test mode, the insertion loss (dB) and the reference value is displayed simultaneously. Short press “dB” to switch linear power and absolute power display. The units of linear power, absolute power and relative power are W, dBm and dB respectively.
Pabs.p=10lglin.p/1mW
Prel.p=Pabs.p-Pref.p

Switch the Wavelength

In the interface of OPM, short press the λ key to switch the measurement wavelength. Ten different wavelengths can be selected: 1310nm, 1550nm, 1577nm, 1490nm, 1625nm, 1650nm, 850nm, 1270nm, 1300nm and 980nm. In order to ensure the accuracy of the test, the selected wavelength must be consistent with the measured optical signal.

RJ45 Cable Sequence and Analog Cable Tracking

In the test interface of OPM, long press the dB key to display the word “RJ45” on the screen. At this time, enter the RJ45 cable sequence test, connect one end of the network cable to the RJ45 port in the bottom, and connect the other end to the remote tester. Short press the dB key to exit. Long press the dB key again, “ ”displays on the upper left corner of the screen, enter the cable tracking mode, and short press the dB key to exit.

VFL and LED flashlight

Optical-ULTIMODE-OPM-2-Multi-Meter-FIG
7

After power on, long press the /VFL key to turn on the VFL, short press to flash and turn off.
Press the power button to control the flashlight turn on and off.

Calibration instructions
At the same time, press the LED+REF key to clear the user’s calibration value, and the screen will full display “-” to restore default value; press the LED+VFL to enter the calibration mode, and “Cal” will be displayed in the upper left corner of the screen. The following operations are only valid in the calibration mode.

Key Function
/VFL Increase 0.05dB
dB Reduce 0.05dB
  Save
λ Switch wavelength

Troubleshooting

Fault Hint Possible Reasons Settlement
LCD display is weak Insufficient Power

Supply

| Replacement Battery
Boot-up cannot be

displayed

| Insufficient power

supply or other

| Reboot or replace

batteries

Abnormal optical power values|

Joint failure,dirty

| Reconnect

Connector and Clean Sensor

Specifications

Optical Power Meter

Wavelength Range| 800~1700nm
Connector| Universal joint
Detector Type| InGaAs
Power Test Range| -70~+10dBm|
Uncertainty| ±5%
Standard Wavelength| 850/980/1270/1300/1310/1490/1550/1577/

1625/1650nm

Display Resolution| Linear display: 0.1%, Logarithmic display:

0.01dBm

Recognizable

Frequency

| 270Hz、300Hz、1kHz、2kHz
VFL (optional)
Wavelength| 650nm±30nm
Output Power| 2mw/15mw/30mw
Mode| CW/1Hz/2Hz
Connector| Universal joint
RJ45 Cable Sequence (standard), Cable Tracking (Optional)
Test Distance| 300m
Others
Power Supply| Lithium Battery, 3.7V/700mAh
---|---
Port| Micro USB
Battery Duration| ≥120h (OPM)
Automatic Shutdown

Time

| 10min
Working Temperature| -10℃~+50℃
Storage Temperature| -40℃~+70℃
Relative Humidity| 0~95% No condensation
Dimension| 12070.527.5mm
Weight| 130g

Standard Configuration
OPM host, OPM & VFL all-in-one machine (optional), certificate, operation manual, two AAA batteries, lithium batteries (optional), data line (optional), universal joint, packaging carton
Note: the ratedcharging voltage of lithium battery is 5V/1A.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Optical User Manuals

Related Manuals