LUTRON RRST-ANF RadioRA 3 Fan Control User Guide

July 22, 2024
Lutron

LUTRON RRST-ANF RadioRA 3 Fan Control

LUTRON-RRST-ANF-RadioRA-3-Fan-Control-PRO

Product Information

Specifications:

  • Model: RRST-ANF
  • Input Voltage: 120 V~
  • Frequency: 50 / 60 Hz
  • Current: 1.5 A

Product Usage Instructions

Setting Up the Fan Control:

  1. Set the fan speed to the highest setting using the pull chain.
  2. Turn off the power at the circuit breaker.
  3. Remove the existing switch from the wall by detaching the wallplate and pulling the switch away from the wall.
  4. Disconnect all three wires from the switch – ground, neutral, and fan/tagged wire.
  5. Connect the wires as follows:
    • Connect the bare copper (or green) ground wire from the wall box to the green wire on the fan control.
    • Connect the neutral wire from the wall box to the white wire on the fan control.
    • Connect the fan/tagged wire from the wall box to the yellow wire on the fan control.
  6. Mount the fan control on the wall securely.
  7. Turn the power back on.

Set-Up with System:
For integration into a RadioRA 3 system, refer to www.lutron.com/RA3support for detailed instructions on system compatibility and setup requirements.

Operation:

  • ON: Adjust between four speeds – High, MediumHigh, Medium, and Low.
  • OFF: Fan control is turned off.

Additional Resources:

Frequently Asked Questions (FAQ):

  • Q: What types of fans are compatible with this Fan Control?
    A: This Fan Control is designed for use with AC fans only. It is not suitable for DC motor fans, fans with remote controls, Wi-Fi-only fans, or exhaust fans (bathroom or kitchen).

  • Q: Can I use this Fan Control with integrated fan speed controls?
    A: This Fan Control is intended for use with fans that have a pull chain for speed control. Do not use it with fans that have integrated controls like remote controls or Wi-Fi connectivity unless those integrated controls are removed from the ceiling fan.

Not for use with DC motor fans, fans with a remote control, Wi-Fi only fans, or exhaust fans (bathroom or kitchen exhaust fans).

IMPORTANT NOTES

  1. For indoor use only.
  2. Operate between 32 ˚F (0 ˚C) and 104 ˚F (40 ˚C).
  3. Use to control one paddle-type ceiling fan.
  4. Use the ceiling fan’s pull chain to set its speed to the highest setting.
  5. Do not use to control fans that have integrated fan speed controls other than a pull chain (i.e., fans that have a remote control or Wi-Fi), unless the integrated control is removed from the ceiling fan.
  6. Do not connect to any other motor-operated appliance or to any lighting load type.
  7. Do not use to control lighting loads on a fan.
  8. Not compatible with Sunnata companion dimmers or switches.

Installing your fan control

  1. Set the fan speed
    Set the fan to the highest speed using the pull chain.

  2. Turn power off at circuit breaker!
    WARNING: SHOCK HAZARD.

    May result in serious injury or death. Turn off power at circuit breaker or fuse before installing.

  3. Remove existing switch from wall
    Remove the wallplate from the switch.
    Pull the switch away from the wall.LUTRON-RRST-ANF-RadioRA-3-Fan-Control-
\(2\)
    Place tag on fan wire (if unsure, pick one, and if the fan does not work turn power off, and swap wire).
    Disconnect all three wires from the switch.

  4. Connect the fan control

  5. Connect the bare copper (or green) “ground” wire from the wallbox to the green wire on the fan control using a wire connector.

  6. Wrap line/hot wire around screw terminal, and tighten securely. Torque reference: 5 in-lb (0.55 N•m).

  7. Connect the neutral wire from the wallbox to the white wire on the fan control using a wire connector.

  8. Connect the fan/tagged wire from the wallbox to the yellow wire on the fan control using a wire connector.

  9. Mount the fan control on the wall.

  10. Turn the power back on.

  11. Set-Up with system
    For use in a RadioRA 3 system, please refer to www.lutron.com/RA3support For reliable performance in a system, Clear Connect-Type X devices must be placed within 25 ft (7.6 m) or within 75 ft (22.86 m) of the wireless processor / gateway devices of two additional compatible Clear Connect-Type X devices.
    Examples of Clear Connect-Type X devices include RadioRA 3 Sunnata dimmer, fan control, switch, keypad and RadioRA 3 wireless processor/gateway devices. Companion devices are excluded from the list of compatible devices because they are not Clear Connect- Type X devices. Companion devices have wired communication with the main device.
    For more information please refer to the Wireless Setup guide: www.lutron.com/RA3support

Operation

Troubleshooting

LUTRON-RRST-ANF-RadioRA-3-Fan-Control- \(6\)

CAUTION
Use only with permanently installed ceiling fans. To avoid overheating and possible damage to other equipment, do not use to control receptacles, motor- driven appliances, or transformer-supplied appliances.

Codes
Install in accordance with all national and local electrical codes.

Grounding
When no “grounding means” exist in wallbox, the National Electrical Code (NEC®) allows a control to be installed as a replacement if 1) a nonmetallic, noncombustible faceplate is used with nonmetallic attachment screws or 2) the circuit is protected by a ground fault circuit interrupter (GFCI). When installing a control according to these methods, cap or remove green wire before screwing control into wallbox.

FCC / IC INFORMATION

This device complies with part 15 of the FCC Rules and Innovation, Science, and Economic Development Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference, including interference that may cause undesired operation.

Modifications not expressly approved by Lutron Electronics Co., Inc. could void the user’s authority to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Suppose this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on. In that case, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and receiver
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC/ISED radiation exposure limits set forth for an uncontrolled environment. The user should avoid prolonged exposure within 7.9 in (20 cm) of the antenna, which may exceed FCC/ISED radio frequency exposure limits.

Help
Use our mobile-friendly self-paced installation tool: www.lutron.com/wiringwizard
Find more product information: www.lutron.com/support
– Videos
– Frequently Asked Questions
Call us:
U.S.A. | Canada | Caribbean
1.844.LUTRON1 (588.7661) (24/7)
Mexico +1.888.235.2910
Others +1.610.282.3800
www.lutron.com/RA3support

Limited Warranty:
www.lutron.com/warranty or call 1.844.LUTRON1 for a printed copy.

Lutron, the Lutron Logo, FASS, RadioRA 3, and Sunnata are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries. All other product names, logos, and brands are property of their respective owners.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals