Z-TRM6 DC TRM6 DC Is An Electr
“`html
Specifications
-
Product: Heatit Z-TRM6 DC
-
Modes: Heat, Cool, Eco
-
Frame: Sturdy metal frame for secure fastening on standard
European junction boxes -
Temperature Sensors: 1 built-in room temperature sensor, 2
additional external temperature sensors -
Power Metering: Manual setting available
-
Associations: Multiple associations possible, can be used as a
master thermostat to control up to 10 thermostats and 10 external
relays -
Relay: Built-in potential free relay of max 3A for usage with
up to 3x 24VDC actuators
Product Usage Instructions
Quick Start
- Switch off the mains voltage (disable the fuse).
- Open the junction box.
- Connect the wires according to the provided description.
Installation Disclaimer
Installation must be done by a qualified electrician following
national building codes. Disconnect power from the mains before
installation and keep power to the device disconnected at all times
during installation.
Connections
Max tightening torque for terminal screws: 2Nm. Use end sleeves
for cables with multiple strands. The device allows wiring of
cables with a cross-section of up to 1×2.5mm². Screw terminals are
located at the back and accessible at all times.
Installation
To install the thermostat:
-
Hold the sides of the display and gently pull outwards to
detach the front piece. -
Connect all wires according to the correct diagram.
-
Align the thermostat with the junction box mounting screws and
mount it using 2 screws. -
Position the thermostat front over the part in the junction box
and press until it clicks into place.
FAQ
Q: How many external temperature sensors can be connected to
the Heatit Z-TRM6 DC?
A: Two additional external temperature sensors can be connected
to the thermostat.
Q: What is the maximum number of thermostats and external
relays that can be controlled by the Heatit Z-TRM6 DC?
A: The thermostat can control up to 10 thermostats and 10
external relays, such as wall plugs.
Q: What is the maximum current rating for the built-in relay of
the Heatit Z-TRM6 DC?
A: The built-in potential free relay has a maximum rating of 3A
for usage with up to 3x 24VDC actuators.
“`
HEATIT Z-TRM6 DC
Installers manual
PRODUCT DOCUMENTS
Firmware version
FW 1.0
Article no.
54 305 61 54 305 63
Document version
2024-B
Document date
22.02.2024
Org. doc. date 02.01.2024
White RAL 9003 54 305 61
Black matt 54 305 63
TABLE OF CONTENTS
1. Introduction 2. Statement regarding
products from multiple manufacturers 3. Behavior within the Z-Wave network 4.
Quick start 5. Disclaimer installation 6. Connections 7. Installation 8.
Add/Remove 9. Factory reset 10. Startup 11. Principles of regulation 12. Local
settings menu 13. Display menu structure 14. Temperature shown in display 15.
Standby and main screen 16. KWh value in menu 17. Size of load 18. Choice of
sensor 19. Selecting sensor value 20. Calibration
21. Brightness 22. Display on/off 23. Display icons 24. Child lock 25. Open
window detection 26. Error codes 27. Safety features 28. QR-Code placement
(DSK) 29. Security 30. Node information frame 31. Associations 32. Association
groups 33. Configuration parameters 34. Command classes 35. Supported command
classes 36. Controlled command
classes 37. Thermostat dimensions 38. Thermostat controls 39. Chart – Display
menu
Product info
1. INTRODUCTION Heatit Z-TRM6 DC is an electronic thermostat with a potential
free relay, designed for boiler control, heat pumps and actuators. The
thermostat can be controlled through your Z-Wave® network or via the buttons
on the front. The thermostat has a user friendly interface.
Heatit Z-TRM6 DC has 3 modes; Heat – Cool and Eco.
The thermostat fits in standard European junction boxes and may be used with
most System 55 frames. It has a sturdy metal frame for secure fastening on the
junction box. The thermostat has one built-in room temperature sensor. Two
additional external temperature sensors may also be connected.
Heatit Z-TRM6 DC allows you to set the power metering value manually.
The thermostat can be set up with multiple associations and can be used as a
master thermostat. It can control up to 10 thermostats and 10 external relays
E.g wall plugs.
The device has a built-in potential free relay of max 3A that is designed for
the usage of up to 3x 24VDC actuators.
2. STATEMENT REGARDING PRODUCTS FROM MULTIPLE MANUFACTURERS
Please read this before installation This device may be used with all devices
certified with the Z-Wave Plus® certificate and should be compatible with such
devices produced by any manufacturer. Every primary controller is different
depending on the manufacturer, their target audience and intended
use/application. Please review the functionalities implemented by the primary
controller you intend to use with our Z-Wave Plus certified device to ensure
that it provides the necessary controls to take full advantage of our
product’s capabilities.
3. BEHAVIOR WITHIN THE Z-WAVE NETWORK This device may be operated within any
Z-Wave® network with Z-Wave-certified devices from other manufacturers. All
non-battery-operated nodes within the network will act as repeaters regardless
of manufacturer to increase the reliability of the network. On delivery, the
device does not belong to any Z-Wave network. The device needs to be added to
an existing network to communicate with the other devices within it. Devices
may also be removed from a network. The add/ remove processes are initiated by
the primary controller of the Z-Wave network.
4. QUICK START 1. Switch off the mains voltage (disable the fuse). 2. Open
the junction box. 3. Connect the wires according to the description in
Chapter 6; “Connections”. Optional: Connect external wired sensors. 4. After
verifying the connections, switch on the mains voltage. 5. Set the primary
controller in add mode (security/nonsecurity). 6. Hold the Center button until
“OFF” is shown in the display (approx. 5 seconds). 7. Press the “+” button
once to reach “CON”, and hold the center button until the display shows a
rotating light pattern. 8. The thermostat will display “INCL” when the
thermostat is successfully added. NB! If adding/removing fails, Err (error)
will appear.
5. INSTALLATION DISCLAIMER Installation must be done by a qualified
electrician in accordance with national building codes. Before installation,
disconnect the power to the device from the mains. During installation of the
device, power to the device must be disconnected AT ALL TIMES!
6. CONNECTIONS Max tightening torque for terminal screws: 2Nm. If the cable
used has multiple strands, using a end sleeve is advised. The product allows
for wiring of cables with a cross section of up to 1×2.5mm2.
The screw terminals are located at the back of the device, and are accessable
at all times.
24VDC
NTC NTC
Heatit Z-TRM6 DC
Art. no. 54 305 61 54 305 62 54 305 63
Flosoenr sor Exste. nsor
heatit.com
230VAC~50/60Hz 3A 24VDC
Out In
N
L
Potential-free input e.g. for boiler control, heat pumps etc.
Floor sensor
External sensor
Out In N L
NTC type 6.8, 10, 12, 15, 22, 33, 47 or 100k. Default 10k. NTC type 6.8, 10, 12, 15, 22, 33, 47 or 100k. Default 10k. Output. Input. Power connection (Neutral) 230VAC. Power connection (Live) 230VAC.
7. INSTALLATION To install the thermostat in the junction box, hold the sides of the display and gently pull outwards to detach the front piece. Connect all wires according to the correct diagram. Align the thermostat with the junction box mounting screws, and mount it into the junction box using 2 screws. Position the thermostat front over the part mounted in the junction box, then carefully press the front until it clicks into place.
Heatit Z-TRM6 DC
Art. no. 54 305 61 54 305 62 54 305 63
Flosoenr sor Exste. nsor
heatit.com
230VAC~50/60Hz 3A 24VDC
Out In
N
L
NTC NTC
Potential-free input
8. ADD/REMOVE Please read this before installation The primary
controller/gateway has a mode for adding or removing devices. Please refer to
your primary controller manual on how to set the primary controller in
add/remove mode. The device may only be added or removed from the network if
the primary controller is in add/remove mode. When the device is removed from
the network, it will NOT revert to factory settings.
An always listening node must be powered continuously and reside in a fixed
position in the installation to secure the routing table. Adding the device
within a 2 meter range from the gateway can minimize faults during the
Interview process.
There are two ways to add the device to a Z-Wave network.
8.1 Method 1: Standard (Manual) Add/remove mode is indicated on the device by
rotating LED segments on the display. It indicates this for 90 seconds until a
timeout occurs, or until the device has been added to/ removed from the
network. Configuration mode can also be cancelled by performing the same
procedure used for starting Configuration mode.
1. Hold the Center button for 5 seconds. The display will show “OFF”.
2. Press the “+” button once to see “CON” in the display. 3. Start the
add/remove device process in your primary
controller. 4. Start the configuration mode on the thermostat by holding
the Center button for approximately 2 seconds.
The device is now ready for use with default settings.
NB! When the device is removed from the gateway, the parameters are not reset.
To reset the parameters, see Chapter “Factory reset”.
If inclusion fails, please perform a “remove device” process and try again. If
inclusion fails again, please see “Factory reset”.
8.2 Method 2: SmartStart (Automatic) SmartStart enabled products may be added
to a Z-Wave network by scanning the Z-Wave QR-Code on the product if your
primary controller supports SmartStart inclusion. No further action is
required and the SmartStart product will be added automatically after being
powered on within range of the primary controller.
9. FACTORY RESET Enter the menu by holding the Center button for about 5
seconds, navigate in the menu with the “+” button til you see FACT. Press the
Center button until you see “– –” blinking in the display, then hold for about
5 seconds to perform a reset. You may also initiate a reset by holding the
Right and Center buttons for 60 seconds.
When either of these procedures has been performed, the thermostat will
perform a complete factory reset. The device will display “RES” for 5 seconds
while performing a factory reset. When “RES” is no longer displayed, the
thermostat has been reset.
Please use this procedure only when the primary controller is missing or
otherwise inoperable.
10. STARTUP After powering up the device for the first time, all parameters
will have default settings and the thermostat will start by asking which
sensor mode should be used.
11. PRINCIPLES OF REGULATION The thermostat uses temperature readings
retrieved from the internal sensor and/or from external wired sensors to
regulate the temperature. The thermostat will regulate the temperature using
hysteresis or PWM, based on the setpoint temperature. To select either “HYST”
or “PWM” you can find the “REG” menu option or use Parameter 13 “REG”.
11.1 Hysteresis Hysteresis will turn on and off the load based on the
hysteresis value in comparison to the setpoint. You can make changes to the
thermostat hysteresis. You may choose hysteresis values between 0.3°C and
3.0°C using Parameter 14 “HYST”. The default setting is 0.5°C. When using
waterbased heating we recommend a hysteresis of 1.0°C.
You may also change the hysteresis by entering the local settings menu and
holding the Center button for 2 seconds when “REG” is displayed. Here you can
choose values between 0.3 and 3.0.
11.2 Pulse-width modulation PWM With pulse-width modulation (PWM) regulation
enabled, the thermostat will regulate based on duty cycles. The thermostat is
turned on and off in percentage intervals of the cycle. The amount of time the
relay will be on is based on how far the measured temperature is from the
setpoint.
12. LOCAL SETTINGS MENU To enter the settings menu, hold the Center button
for 5 seconds. The display will display “OFF”. You are now in the settings
menu. While in the settings menu, “SET” will be displayed in the bottom right
of the display. You can now scroll up and down using the Left and Right
buttons. Some options have submenus. To navigate the submenus, press the
Center button once to enter or exit the submenu. Press the Left and Right
buttons to find your desired value and hold the Center button for 2 seconds to
confirm your selection. “STOR” will appear to indicate settings are stored.
13. DISPLAY MENU STRUCTURE See flowchart at the end of this manual.
14.TEMPERATURE SHOWN IN DISPLAY By default, the temperature shown on the display while in standby state is the setpoint. This may be altered with Parameter 15 “Temperature display”. It may also be changed by entering the local settings menu and holding the Center button for 2 seconds when “MODE” is displayed. You can choose between “SETT” and “RELT”. “SETT” is the Setpoint temperature and “RELT” is the real-time temperature.
15. STANDBY AND MAIN SCREEN When the thermostat remains untouched for a while, it will automatically go to the standby screen. The standby will by default show the setpoint temperature. By pressing any button once, you will see the measured temperature. By pressing the Left or Right button multiple times, you will change the setpoint.
16. KWH VALUE IN MENU The device supports setting power metering values to give insight into the power consumption of the heating. The total consumption of the device can be seen in the system from the “kWh” menu option. The total consumption data can be reset by holding the Center button while in the kWh menu.
17. SIZE OF LOAD In the “load” menu or from Parameter 27 “Size of load”, the load value can be set manually. The size of load can be adjusted in 100W increments up to 9900W.
18. CHOICE OF SENSOR The thermostat has multiple sensors and sensor modes. This lets you configure the thermostat to work correctly in most installations. The sensors and modes may be selected from either the local settings menu or via Parameter 2 “OPER”.
Available sensor modes:
F
Floor sensor
A
Internal room sensor
AF
Internal room sensor + Floor sensor
A2
External room sensor
A2F External room sensor + Floor sensor
NOTE: Some types of floor require that a floor sensor is connected in order to limit the floor temperature to a maximum of 27°C (check the manual from the floor manufacturer). When the thermostat is used in (AF or A2F) the floor limiter FHI is automatically set to 27°C. When using any other sensor type (A, F or A2) the minimum and maximum limits are 5°C and 40°C respectively.
19. SELECTING SENSOR VALUE The thermostat allows the selection of multiple different resistance values of an NTC sensor and can be selected using either the local settings menu or via Parameter 3 “SEN”. The supported sensor values are as follows: 6.8, 10, 12, 15, 22, 33, 47 or 100K. The factory default value is 10k. When connecting both the floor sensor and the external sensor, make sure to use sensors with the same Ohm value.
20. CALIBRATION If the temperature sensor readout is not correct, you can make minor changes to the temperature readout. The temperature readings can be calibrated by ±6°C using Parameter 10 “CAR”, 11 “CAF” and 12 “CAE”. The calibration can also be performed from the menu using CAR, CAF and CAE. The adjusted value will be displayed in the controller/gateway indicating what the thermostat uses for regulation.
SENSOR TYPE
Internal sensor External sensor Floor sensor
IN MENU STRUCTURE
CAR CAE CAF
PARAMETER
10 11 12
21. BRIGHTNESS Using the menu choices “BR1” and “BR2”, the brightness of the display in Active and Standby state can be changed respectively. “BR1” and “BR2” are also included in the device as Parameter 16 “BR1” and Parameter 17 “BR2”.
22.DISPLAY ON/OFF (DON/DOFF) The thermostat has a display ON/OFF function which decides whether the display should turn completely off when in Standby. To enable/disable this function, hold the Left and Center buttons for 10 seconds. The display will show “DOFF” when the function is activated and “DON” when the function is disabled. When operating any button, the display will light up.
23. DISPLAY ICONS
ICON
DESCRIPTION This icon will be displayed while the relay is on and the
thermostat is in either Heating or Eco mode. This icon will be displayed while
the relay is on and the thermostat is in Cooling mode.
This icon shows the current signal strength.
24.CHILD LOCK Child lock is a function for disabling the buttons from the
display locally. It will show “LOCK” when attempting to operate it while the
function is enabled. To enable or disable the function, hold the Left and
Right buttons for 10 seconds. Enabling the function will show “LOCK” in the
display, disabling the function will show “OPEN”.
25. OPEN WINDOW DETECTION OWD Open Window Detection (OWD) is a function which
will reduce the thermostat setpoint on detection of an open window. This
happens when the temperature sensor registers a rapid temperature drop.
When OWD is active, the setpoint is reduced to 5°C in order not to waste
energy. OWD will automatically be cancelled if OWD has been active for more
than 1 hour, or if the temperature increases by 3°C. OWD can also be cancelled
manually by increasing/decreasing the setpoint with the Left and Right
buttons.
By default, OWD is not enabled. The feature may be enabled by selecting “OWD”
from the menu. Choose between options “OFF” and “ON”. It can also be enabled
by setting Parameter 26 “Open window detection” to 1.
26. ERROR CODES Err Adding fail. See Chapter 7 “Add/remove”. Err1 Internal
error. Most probably a faulty unit. Replace unit. Err2 Z-Wave error. Most
probably a faulty unit. Replace unit. Err3 Internal error. Most probably a
faulty unit. Replace unit. Err4 Floor sensor error. You have chosen F, AF or
A2F sensor
mode without having a floor sensor connected, or the sensor may be damaged.
Err5 External sensor error. You have chosen A2 or A2F sensor mode without
having an external sensor connected, or the sensor may be damaged. Err6
Overheating. Contact your electrician.
27. SAFETY FEATURES The device has safety features to ensure safe operation
and warn the user of any faults/unexpected behavior. The device has an
Overheat function. If the thermostat registers an Overheat incident, the
thermostat will switch off and an error will appear in the display.
27.1 Overheating The device features internal temperature sensors that detect
overheating. It warns the user and turns off the relay to prevent any damage.
When overheating is detected, the device will: · Turn off the relay. · Display
Err6 in the display. · Send a notification to the gateway.
27.2 Sensor failure The device has the ability to detect when there is no
sensor connected or the sensor is broken or otherwise defective, causing an
open circuit. When the device detects the sensor error, the device will: ·
Turn off the relay. · Display an error in the display, changes based on which
sensor is not connected/faulty.
To clear the “Sensor not connected” error the device has to be disconnected
from the mains, and the wiring and sensor(s) need to be checked. When the
fault is resolved the mains can be reconnected and the device will function
normally again.
28.QR-CODE PLACEMENT (DSK) The QR-Code is needed when including a device using
S2 security or SmartStart. The DSK can be found in the QR-Code and is located;
· On the product. · In the Quick Guide. · On the packaging box/gift box.
29. SECURITY S2 security enhances Z-Wave Plus with an additional layer of AES
128-bit encryption of the wireless Z-Wave communication to prevent hacking and
man-in-middle attacks on the home network.
This device supports S2 and has a Z-Wave DSK QR-Code label that may be used when the device is added to the Z-Wave home network. The primary controller will ask for a 5-digit code. They are the first underlined 5 digits located on the QR code sticker. The primary controller will then ask you to confirm the rest of the code that is contained in the QR-Code.
30. NODE INFORMATION FRAME The node information frame is the “business card” of a Z-Wave device. It contains information about the device type and its technical features. The add and remove procedure of the device is confirmed by sending out a node information frame. Besides this, it may be necessary for certain network operations to send out a node information frame.
31. ASSOCIATIONS
Z-Wave devices interact with other Z-Wave devices. The relationship between
one device controlling another device is called an association. In order to
control a subordinate device, the controlling device needs to maintain a list
of devices that will receive controlling commands. These lists are called
“Association Groups”. They are always related to the specific event triggered
(e.g., sensor reports). In case the event is triggered, all devices stored in
the respective association group will receive a joint wireless command.
31.1 Setting and Removing Associations Associations may be assigned and removed via Z-Wave commands. Please refer to your primary controller/Z-Wave gateway for more information.
31.2 Multi Channel support Heatit Z-TRM6 DC has support for the Multi Channel Command Class. This allows the thermostat to be perceived as multiple devices by the primary controller, which enables the reporting of multiple temperature sensors and the ability to distinguish between the reports coming from the device.
31.3 No Multi Channel support If the primary controller or the Z-Wave devices to be associated with Heatit Z-TRM6 DC do not support the Multi Channel Association Command Class (Multi Channel encapsulation), only the association groups in the root device are accessible. This device contains 3 association groups in addition to the Lifeline Group.
32. ASSOCIATION GROUPS Without Multi Channel support:
MULTI LEVEL SWITCH DEVICE Group 1
DESCRIPTION
Lifeline. Lifeline Group to be used by primary controller, sends: -Thermostat
Mode Report -Thermostat Setpoint Report -Thermostat Operating State Report
-Protection Report -Notification Report -Meter Report -Sensor Multilevel
Report -Device Reset Locally Notification -Indicator Report -Configuration
Report
Group 2
Max nodes in group: 1
Binary Switch Set. Send Binary Switch set commands based on the internal relay
state, sends: -Binary Switch Set
Max nodes in group: 10
PARA NO# PARA SIZE (BYTE) MIN MAX DEFAULT 43200
MULTI LEVEL SWITCH DEVICE Group 3
DESCRIPTION
Thermostat Setpoint set. Sends Thermostat Setpoint set commands based on own
setpoint to allow for use as master thermostat, sends: -Thermostat Setpoint
Set
Group 4
Max nodes in group: 10
Thermostat Mode set. Sends Thermostat Mode set commands based on own mode to
allow for use as master thermostat, sends: -Thermostat Mode Set
Max nodes in group: 10
With Multi Channel support:
1: THERMOSTAT DEVICE Group 1
THE MAIN THERMOSTAT DEVICE
Lifeline. Lifeline Group to be used by primary controller, sends: -Thermostat
Mode Report -Thermostat Setpoint Report -Thermostat Operating State Report
-Protection Report -Notification Report -Meter Report -Sensor Multilevel
Report -Device Reset Locally Notification -Indicator Report -Configuration
Report
Group 2
Max nodes in group: 1
Binary Switch Set Send Binary Switch set commands based on the internal relay
state, sends: -Binary Switch Set
Group 3
Max. nodes in group: 10
Thermostat Setpoint Set Sends Thermostat Setpoint set commands based on own
setpoint to allow for use as master thermostat, sends: -Thermostat Setpoint
Set
Group 4
Max. nodes in group: 10
Thermostat Mode Set. Sends Thermostat Mode set commands based on own mode to
allow for use as master thermostat, sends: -Thermostat Mode Set
Max. nodes in group: 10
2: MULTILEVEL SENSOR DEVICE INTERNAL SENSOR
Group 1
Lifeline. Lifeline Group for internal sensor, sends: -Sensor Multilevel Report
Max. nodes in group: 0
3: MULTILEVEL SENSOR DEVICE EXTERNAL SENSOR
Group 1
Lifeline. Lifeline Group for external sensor, sends: -Sensor Multilevel Report
Max. nodes in group: 0
4: MULTILEVEL SENSOR DEVICE FLOOR SENSOR
Group 1
Lifeline. Lifeline Group for floor sensor, sends: -Sensor Multilevel Report
Max. nodes in group: 0
33. CONFIGURATION PARAMETERS Z-Wave products are supposed to work out of the box after inclusion. Some device configuration may, however, alter the functionality to better serve user needs or unlock further enhanced features. All the parameters below do not feature altering capabilities, advanced or read only flags.
NAME
1
1
Disable buttons
Sensor 2 1 mode
(OPER)
SHORT DESCRIPTION / COMMENT Disable buttons, must be enabled through the
parameter, or turned back on locally by holding the center and right button
for 30 seconds until the display shows “UNLK”.
Choose which sensor mode the device should operate with.
0
1 0 1 2 3
4
DESCRIPTION OF VALUE
Enabled, buttons on the front of the device work. (Default) 0 Disabled,
buttons on the front of the device are disabled. F, Floor sensor A, Internal
sensor (Default) AF, Internal sensor with 1 floor sensor limitations A2,
External sensor
A2F, External sensor with floor sensor limitations
PARA NO# PARA SIZE (BYTE) MIN MAX DEFAULT
NAME
SHORT DESCRIPTION / COMMENT
DESCRIPTION OF VALUE
0
10K (Default)
1
12K
2
15K
3
1
Sensor
Select the resistance value of
value (SEN) the connected NTC.
3
22K
0
4
33K
5
47K
6
6.8K
7
100K
4
Internal
Decides the lowest tempera-
2 sensor min ture allowed by the thermostat 50
temp limit when using sensor mode A.
400
50
5°C to 40°C (Default is 5°C)
5
2
Floor sensor min temp limit
Devices the lowest temperature allowed by the thermostat when using sensor mode AF, F, A2F.
50
400
50
5°C to 40°C (Default is 5°C)
6
2
External sensor min temp limit
Decides the lowest temperature allowed by the thermostat when using sensor mode A2, A2F.
50
400
50
5°C to 40°C (Default is 5°C)
7
Internal
Decide the highest tempera-
2 sensor max ture allowed by the thermostat 50
temp limit when using sensor mode A.
400
400
5°C to 40°C (Default is 40°C)
8
2
Floor sensor max temp limit
Decide the highest temperature allowed by the thermostat when using sensor mode AF, F, A2F.
50
400
400
5°C to 40°C (Default is 40°C)
9
External
Decide the highest tempera-
2 sensor max ture allowed by the thermostat 50
temp limit when using sensor mode A2.
400
400
5°C to 40°C (Default is 40°C)
Internal
10
1
sensor
Manually calibrate sensor
calibration A ±6°C.
(CAR)
-60 60
-6.0°C to 6.0°C Calibrates the sensor by ±6°C. (Default is 0°C) 0 NB! To set a negative value, use 256 and subtract the desired value.
Floor
11
1
sensor
Manually calibrate sensor
calibration F ±6°C.
(CAF)
-60 60
-6.0°C to 6.0°C Calibrates the sensor by ±6°C. (Default is 0°C) 0 NB! To set a negative value, use 256 and subtract the desired value.
External
12
1
sensor
Manually calibrate sensor
calibration A2 ±6°C.
(CAE)
-60 60
-6.0°C to 6.0°C. Calibrates the sensor by ±6°C. (Default is 0°C) 0 NB! To set a negative value, use 256 and subtract the desired value.
13
1
Regulation mode (REG)
Choose between regulation modes PWM and Hysteresis.
0
1
Hysteresis (Default) 0
PWM regulation
14
1
Temperature control hysteresis (HYST)
Choose the hysteresis used when regulation mode is set to HYST.
3
30
10
0.3°C to 3.0°C. Default is 10 (1.0°C)
15
1
Tempera- Select what is shown on the ture display display during Standby state.
0
1
Display setpoint temperature. (Default) 0 Display measured temperature.
Active
16
1
display brightness
Configure the brightness of the display during active state.
1
10
10
10 to 100% (Default 100%)
(BR1)
Standby
17
1
display brightness
Configure the brightness of the display during standby state.
1
10
5
10 to 100% (Default 50%)
(BR2)
Tempera- Set the time interval between
18 2 ture report consecutive temperature
interval
reports.
30 to 65535 seconds. 30 65535 840 840s (14 min 5 sek)
(Default)
Tempera- Set the change in temperature 19 1 ture report required to send a
temperature 1
hysteresis report based on change.
100
10
0.1°C to 10°C 10 (1°C) (Default)
0, device will turn off
0
and show an error in the
display. (Default)
20
2
Action after error
Decide how the device should react when the overheating features has turned OFF relay.
0 10 to 65535 seconds, device will attempt to turn on
10 65535
again after an error based
on the delay specified. Will
display error if off.
21
2
Heating setpoint
Set setpoint for Heating mode. 50
400
210
5°C to 40°C. 21°C (Default)
22
2
Cooling setpoint
Set setpoint for Cooling mode. 50
400
180
5°C to 40°C. 18°C (Default)
23
2
ECO setpoint
Set setpoint for ECO mode.
50
400
180
5°C to 40°C. 18°C (Default)
24
2
Thermostat state update interval
Set the time interval of how often the device updates Thermostat Setpoint set, Thermostat Mode set and Binary set to associated devices.
0 30 65535
Sends only when changed.
30 to 65535 seconds. 43200 seconds + when changed. (Default)
PARA NO# PARA SIZE (BYTE) MIN MAX DEFAULT
NAME
SHORT DESCRIPTION / COMMENT
0 Operating
25 1 Mode
Set the thermostat mode.
1
(MODE)
2
3
Open 26 1 window
detection
Choose to enable or disable the Open windows detection.
0 1
Allows the user to decide
27
2
Size of load
the power consumption of the connected load in 100W
increments.
0 1 99
28
1
Inverted output
Valve 29 1 inactivity
exercise
Decides if the device output should be inverted.
Relay will turn on to open valves for the selected amount of time after 30
days of inactivity.
0 1 0
1 30
DESCRIPTION OF VALUE
OFF Thermostat will not operate
1 Heating mode (Default) Cooling mode
ECO mode
Open window detection disabled. (Default) 0 Open windows detection enabled.
Uses power metering values. (Default)
1-99 = 100-9900 Watt Allows the user to set the size of the load, used when
connected to a contactor.
0 Inverted output
Valves do not open
periodically. (Default).
0
1 to 30 minutes, amount of time relays should be
turned on for after 30 days
of relay inactivity.
34.COMMAND CLASSES Additional information regarding Command Classes and their functionality:
34.1 Basic Command Class A Basic command to the device will change the thermostat mode. Uses the following values: 0x00 = OFF (0x00) 0xFF = HEAT (0x01)
If the thermostat is in ECO or COOL mode, 0x00 will still change the mode to OFF. ECO or COOL cannot be enabled with a Basic Set command.
34.2 Meter Command Class The device supports Meter Command Class Get, and the thermostat will only respond on supported electric meter scales: kWh (accumulated) and Watt (instant).
The device will report when asked:
Rate type:
Import (0x01)
Meter type:
Electric meter (0x01)
TYPE Electric
Electric
SCALE kWh
W
VALUE 0x01
0x01
SIZE PRECISION REPORT HYSTERESIS
3600s and on state
4
1
change, not configurable
3600s, state change
4
1
and on change in LOAD parameter, not
configurable
34.3 Protection Command Class Protection Command Class allows you to disable
local control of the thermostat, this is separately from the Child Lock
function.
To enable the Protection Command Class, either set Parameter 1 “Disable
buttons” to value 1, enabling Local Protection State 0x02, or send a
Protection Set with Local Protection State 0x01 or 0x02.
During Protection State 0x01, the device is protected by a button sequence and
allows for no local operation until it is unlocked. To unlock the thermostat
while in Protection state 0x01, first press twice on the Left button, then
press twice on
the Right button and then finally twice on the Center button. This will unlock
the thermostat until it goes back to standby, requiring you to unlock it
again. Protection State to 0x02 means that no operation is possible and the
thermostat can only be unlocked by setting Parameter 1 “Disable buttons” to 0,
or by holding the Center and Right buttons for 30 seconds.
34.4 Thermostat Setpoint Command Class Thermostat Setpoint is implemented with
3 setpoints, Heating, Cooling and ECO. Supported setpoints are from 5°C – 40°C
with 0.5°C increments.
34.5 Thermostat Mode Command Class It is possible to change the operating mode
of the thermostat by sending a Thermostat Mode set command. The accessible
operating modes are: 0x00: OFF (Thermostat regulation and display are
deactivated). 0x01: Heating Mode (Thermostat regulation is active). 0x02:
Cooling Mode (Thermostat regulation is inverted). 0x0B: ECO Mode (Thermostat
regulation is active with a
separate setpoint from Heating Mode).
34.6 Thermostat Operating State Command Class The thermostat reports the
operating state of the interal relay using this Command Class. 0x00 = Idle
0x01 = Heating (used for Heating and ECO mode) 0x02 = Cooling
34.7 Indicator Command Class The device supports the Indicator Command Class. The indicator Command Class will flash the display.
34.8 Notification Command Class The product features security features that announce any action using the Notification Command Class. The following commands are implemented:
NAME Heat alarm
EVEN/ VALUE STAT
0x04 State
STATE VARIABLE
STATE VARIABLE AFTER
Heat sensor status Idle
NOTIFICATION NAME
Overheating detected
VALUE 0x02
34.9 Binary Switch Command Class Binary Switch commands are used to control
external relays associated with group 2. Uses the following values: 0x00 = OFF
0xFF = ON
This Command Class is based on the operating state of the thermostat (relay on
or off).
35. SUPPORTED COMMAND CLASSES The following table lists all Command Classes supported by the Z-Wave device. The device supports S0, S2 Authenticated security and S2 Unauthenticated security.
ASSOCIATION
Association Association Group Information Device Reset Locally Notification
Firmware Update MD Indicator Manufacturer Specific Multi channel Association
Multi channel Power level Security Security v2 Supervision Transport Service
Version Z-Wave Plus Information Configuration Basic Notification Meter Sensor
Multilevel Protection Thermostat Mode Thermostat Operating State Thermostat
Setpoint
VERSION
v2 v3 v1 v5 v3 v2 v3 v4 v1 v1 v1 v1 v2 v3 v2 v4 v2 v11 v5 v11 v1 v3 v1 v3
INSECURE ON SECURE INCLUSION
Yes Yes Yes Yes Yes
SECURE ON SECURE INCLUSION
Yes Yes Yes Yes Yes Yes Yes Yes Yes
Yes
Yes Yes Yes Yes Yes Yes Yes Yes Yes
36.CONTROLLED COMMAND CLASSES
ASSOCIATION Binary Switch
VERSION 2
INSECURE ON SECURE INCLUSION
SECURE ON SECURE INCLUSION
Yes
37. THERMOSTAT DIMENSIONS
45.5mm 22mm 23.5mm
50mm
84mm
38. THERMOSTAT CONTROLS
ICON
DESCRIPTION
Previous. Decrease set temperature.
Menu confirm. Menu enable.
Next. Increase set temperature.
50mm
39. CHART – DISPLAY MENU STRUCTURE Hold the middle button for 5 seconds to
enter menu.
Hold button for 2 seconds
Success Fail
TDS: Temperature displayed in standby mode SETT: Setpoint temperature RELT: Real time temperature
Only shows available options
Only shows available options
Only shows available options
Hold the middle button to set HYST value, from 0.3-3.0
Short hold to change the mode
Load value from 100-9900W, by increments of 100.
Default Default Hold to reset the Kwh.
39.1 Error messages in display Failed to include Internal error: MCU and
Z-Wave chip communication failed Z-Wave error
Internal sensor error
Floor sensor error
External sensor error
Overheat
39.2 General display messages Childlock activated
Childlock disabled Backlight on when device in standby Backlight off when
device in standby Open window detected
Settings stored
PRODUCT INFO
PRODUCT INFO Heatit Z-TRM6 DC 3A
FEATURES
· Z-Wave thermostat
· Adjustable display
· Internal room sensor
brightness
· External room sensor (wired) · Single pole switch
· Floor sensor
· Lock mode/child lock
· Temperature limiter
· Temperature read out in
· Boiler control, heat pumps gateway
· Control of actuators
· Weekly schedule in
· 3 modes; Heat, Cool, Eco
gateway
· Hysteresis/PWM
· Manual power metering
· Temperature calibration
· SmartStart
· Open window detection · Firmware update (OTA)
· Relay status icon
· Supports encryption mode: S0, S2 Authenticated Class, S2 Unauthenticated Class
The product must be used with a security-enabled Z-Wave controller in order to fully utilize security/encryption.
TECHNICAL DATA
Protocol
Z-Wave, 868.4MHz
Chip
Z-Wave 800 chip
Rated voltage
230VAC 50Hz
Max load
3A 24VDC
Max actuators
3x24VDC actuators
Power consumption <2W
Ambient temperature 5°C to 40°C
Temperature range 5°C to 40°C
Storage temperature -30°C to 70°C
Hysteresis
0.3°C to 3.0°C (default 0.5°C)
Humidity
10% to 85% RH
Compatible with NTC-
sensor with values
6.8, 10, 12, 15, 22, 33, 47 or
100k @ 25°C
Range RF
Min. 40 meter
Screw terminals
Max. 2.5mm2 2Nm
IP Code
IP21
Size (LxWxH)
84 x 84 x 45mm
Approvals
Z-Wave Plus v2, CE, Nemko
Heatit Controls AB declares that this product is in
compliance with the essential requirements and other
relevant provisions of Directive 2014/53/EU.
MAINTENANCE The device is maintenance-free. Indoor use only.
DISPOSAL GUIDELINES Do not dispose of electrical appliances as unsorted
municipal waste, use separate collection facilities. Contact your local
government for information regarding the collection systems available. If
electrical appliances are disposed of in landfills or dumps, hazardous
substances can leak into the groundwater and get into the food chain, damaging
health and well-being.
We have designed this product in accordance with our strict quality
requirements (ISO 9001) and environmental requirements (ISO 14001). All
electrical installations must be carried out by an authorized electrical
installer. The product must be installed in accordance with our installers
manual and national building codes. Any wrongful installation, misuse or
damage to the product is not covered under warranty.
Heatit Controls AB can not be held liable for any type of errors or omittances
in our product information. Product specifications may change without further
notice.