VSP 50Hz Pumps with inverters Instructions
- July 18, 2024
- VSP
Table of Contents
- VSP 50Hz Pumps with inverters
- Product Information
- Product Usage Instructions
- Frequently Asked Questions
- INSTALLATION AND USE
- PRODUCT DESCRIPTION
- KEY FEATURES
- ELECTRICAL PANEL
- TYPICAL INSTALLATION
- PERFORMANCE RANGE
- TECHNICAL DATA
- PERFORMANCE CURVES
- DIMENSIONS AND WEIGHT
- DIMENSIONS AND WEIGHT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
VSP 50Hz Pumps with inverters
Product Information
Specifications
- Product Name: VSP Pumps with Inverters
- Application: Clean water for domestic use, civil use
- Features:
- Integrated frequency converter
- Equipped with a pressure sensor for constant pressure
- Easy installation, configuration, and adjustment
- PFC technology for maintaining hydraulic performance
- Integrated protection against various faults
Product Usage Instructions
Installation
VSP is suitable for residential and commercial use. Follow these steps for installation:
- Choose a suitable location for the unit.
- Connect the pump to the water supply line.
- Connect the electrical panel to a power source.
- Ensure proper grounding of the unit.
Configuration
The system comes ready to use, but advanced users can access an advanced menu for modifying factory parameters:
- Adjust the working pressure using the display and keypad.
- View operating parameters and alarm messages via the electrical panel.
- For advanced settings, access the guided procedure in the advanced menu.
Operation
To operate the VSP pumping unit:
- Use the arrow keys for navigation.
- Press ESC to exit menus.
- Toggle ON/OFF using the button provided.
- Confirm actions using the OK button.
Frequently Asked Questions
- Q: What is the purpose of the integrated frequency converter in the VSP?
- A: The integrated frequency converter ensures constant pressure as the system’s water demand fluctuates, providing efficient water supply and pressure boosting.
- Q: How can I access the advanced menu for modifying the factory parameters?
- A: Users can access the advanced menu through a guided procedure on the electrical panel for adapting to specific plant conditions.
INSTALLATION AND USE
VSP is a versatile pumping unit designed for various applications. It’s ideal
for residential and commercial use, providing water supply and pressure
boosting.
VSP seamlessly integrates with any pressurization system, including existing
ones, ensuring maximum comfort and enabling significant energy savings.
PRODUCT DESCRIPTION
VSP is a system comprising a pump and an integrated frequency converter. Equipped with a pressure sensor, it ensures constant pressure as the system’s water demand fluctuates. This ready-to-use product eliminates the need for configuration procedures. Users can adjust the working pressure and view operating parameters and alarm messages via the electrical panel. For advanced users, the system offers access to an advanced menu for modifying factory parameters through a guided procedure, allowing adaptation to specific plant conditions.
VSP is an intelligent pumping unit, equipped with:
- display and keypad allowing simple and intuitive configuration and reading of operating parameters;
- interface ports for additional analogue and digital input and output signals;
- PFC technology maintains hydraulic performance unaffected even when supply voltages vary within ±20% of the nominal value;
- RS 485 communication for connection to a second device in parallel.
Integrated protection against:
- dry running
- overcurrent
- overvoltage and undervoltage
- combustion chamber
- short circuit
- lack of phases in the connections (for three-phase version)
TECHNICAL DATA
- Power supply:
- 1~ 230V±10% or 3~ 400V±10%
- Frequency: 50/60 Hz
- Please refer to the technical data of the specific electro pumps for liquid temperature, ambient temperature, and protection degree.
KEY FEATURES
- Easy installation, configuration, and adjustment.
- Greater comfort, thanks to optimized performance and low noise levels.
- Energy saving reduces startup and operating currents, ensuring.
- Automatic compensation for fluctuations in the supply voltage.
- Communication with another device to enhance system capabilities.
- Intelligent management of control and intervention in case of anomalies.
ELECTRICAL PANEL
It enables access to configuration menus, navigation through settings, adjustment of operating parameters, and activation or deactivation of the pumping unit.
-
Scroll arrow keys
-
ESC menu exit key
-
ON/OFF button
-
Confirmation button
-
4-backlit display to indicate the operating status of the VSP
DISPLAY SYMBOLS -
ALARM warning light
-
AUTOMATIC operation indicator light
-
MANUAL operation indicator light
-
Indicator light for running pump no. 1
-
Indicator light for running pump no. 2 (if present)
-
WI-FI active indicator light (if present)
-
Alphanumeric display with 2 lines for visualization of: voltage, frequency, current, power factor (cosφ), pressure, level, system operating status, system anomalies.
-
VSP operating status LED lights
TYPICAL INSTALLATION
PERFORMANCE RANGE
TECHNICAL DATA
TYPE
Single-phase
| POWER
P2
| ABSORPTION
230 V
| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q
litres/min
| H
metres
| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSPm – FCR 75/90| 1.5| 2| 9.8 A| 5 – 90| 71.5 – 43.5| 1.9| 5 – 60|
4.0| 5 – 86| 7.0| 5 – 16
VSPm – FCR 80/130| 1.5| 2| 9.8 A| 5 – 130| 74.5 – 30| 2.0| 5 – 107|
4.0| 5 – 107| 7.3| 5 – 22
VSPm – FCR 70/200| 1.5| 2| 9.8 A| 5 – 200| 65.5 – 21| 1.8| 5 – 180|
4.0| 5 – 115| 6.4| 5 – 36
TYPE
Three-phase
| POWER
P2
| ABSORPTION
400 V
| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q
litres/min
| H
metres
| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSP – FCR 75/90| 1.5| 2| 3.6 A| 5 – 90| 71.5 – 43.5| 1.9| 5 – 60|
4.0| 5 – 86| 7.0| 5 – 16
VSP – FCR 100/90| 2.2| 3| 4.9 A| 5 – 90| 94 – 62.5| 2.5| 5 – 58|
4.0| 5 – 71| 9.2| 5 – 20
VSP – FCR 80/130| 1.5| 2| 3.6 A| 5 – 130| 74.5 – 30| 2.0| 5 – 107|
4.0| 5 – 107| 7.3| 5 – 22
VSP – FCR 105/130| 2.2| 3| 4.9 A| 5 – 130| 98 – 57.5| 2.7| 5 – 90|
4.0| 5 – 107| 9.6| 5 – 30
VSP – FCR 70/200| 1.5| 2| 3.6 A| 5 – 200| 65.5 – 21| 1.8| 5 – 180|
4.0| 5 – 115| 6.4| 5 – 36
VSP – FCR 95/200| 2.2| 3| 4.9 A| 5 – 200| 87.5 – 42| 2.4| 5 – 178|
4.0| 5 – 175| 8.6| 5 – 32
PERFORMANCE CURVES
DIMENSIONS AND WEIGHT
TYPE | PORTS | DIMENSIONS mm | kg |
---|---|---|---|
Single-phase | Three-phase | DN1 | DN2 |
n | n1 | s | 1~ |
VSPm – FCR 75/90 | VSP – FCR 75/90 | **** |
1¼”
| ****
1″
| ****
445
| ****
75
| ****
139
| ****
260
| ****
145
| ****
59
| ****
242
| ****
129
| ****
113
| ****
185
| ****
145
| ****
11
| ****
21.7
| ****
21.7
–| VSP – FCR 100/90| ****
471
| ****
165
| ****
–
| ****
21.9
VSPm – FCR 80/130| VSP – FCR 80/130| ****
445
| ****
139
| ****
21.9
| ****
21.9
–| VSP – FCR 105/130| ****
471
| ****
165
| ****
–
| ****
21.9
VSPm – FCR 70/200| VSP – FCR 70/200| ****
445
| ****
139
| ****
24.1
| ****
23.9
–| VSP – FCR 95/200| ****
471
| ****
165
| ****
–
| ****
24.0
PERFORMANCE RANGE
TECHNICAL DATA
TYPE
Single-phase
| POWER
P2
| ABSORPTION
230 V
| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q
litres/min
| H
metres
| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSPm – PLURIJET 75/90| 1.5| 2| 9.8 A| 5 – 90| 71.5 – 43.5| 1.9| 5 – 60|
4.0| 5 – 86| 7.0| 5 – 16
VSPm – PLURIJET 80/130| 1.5| 2| 9.8 A| 5 – 130| 74.5 – 30| 2.0| 5 – 107|
4.0| 5 – 107| 7.3| 5 – 22
VSPm – PLURIJET 70/200| 1.5| 2| 9.8 A| 5 – 200| 65.5 – 21| 1.8| 5 – 180|
4.0| 5 – 115| 6.4| 5 – 36
TYPE
Three-phase
| POWER
P2
| ABSORPTION
400 V
| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q
litres/min
| H
metres
| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSP – PLURIJET 75/90| 1.5| 2| 3.6 A| 5 – 90| 71.5 – 43.5| 1.9| 5 – 60|
4.0| 5 – 86| 7.0| 5 – 16
VSP – PLURIJET 100/90| 2.2| 3| 4.9 A| 5 – 90| 94 – 62.5| 2.5| 5 – 58|
4.0| 5 – 71| 9.2| 5 – 20
VSP – PLURIJET 80/130| 1.5| 2| 3.6 A| 5 – 130| 74.5 – 30| 2.0| 5 – 107|
4.0| 5 – 107| 7.3| 5 – 22
VSP – PLURIJET 105/130| 2.2| 3| 4.9 A| 5 – 130| 98 – 57.5| 2.7| 5 – 90|
4.0| 5 – 107| 9.6| 5 – 30
VSP – PLURIJET 70/200| 1.5| 2| 3.6 A| 5 – 200| 65.5 – 21| 1.8| 5 – 180|
4.0| 5 – 115| 6.4| 5 – 36
VSP – PLURIJET 95/200| 2.2| 3| 4.9 A| 5 – 200| 87.5 – 42| 2.4| 5 – 178|
4.0| 5 – 175| 8.6| 5 – 32
PERFORMANCE CURVES
DIMENSIONS AND WEIGHT
TYPE | PORTS | DIMENSIONS mm | kg |
---|---|---|---|
Single-phase | Three-phase | DN1 | DN2 |
n | n1 | s | 1~ |
VSPm – PLURIJET 75/90 | VSP – PLURIJET 75/90 | **** |
1¼”
| ****
1″
| ****
497
| ****
75
| ****
191
| ****
260
| ****
145
| ****
59
| ****
242
| ****
129
| ****
113
| ****
185
| ****
145
| ****
11
| ****
21.7
| ****
21.7
–| VSP – PLURIJET 100/90| ****
523
| ****
217
| ****
–
| ****
23.9
VSPm – PLURIJET 80/130| VSP – PLURIJET 80/130| ****
497
| ****
191
| ****
21.9
| ****
21.9
–| VSP – PLURIJET 105/130| ****
523
| ****
217
| ****
–
| ****
24.1
VSPm – PLURIJET 70/200| VSP – PLURIJET 70/200| ****
497
| ****
191
| ****
21.9
| ****
21.9
–| VSP – PLURIJET 95/200| ****
523
| ****
217
| ****
–
| ****
24.0
PERFORMANCE RANGE
TECHNICAL DATA
TYPE
Single-phase
| POWER
P2
| ABSORPTION
230 V
| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q
litres/min
| H
metres
| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSPm – MK 3/3| 0.75| 1| 6.2 A| 10 – 80| 52 – 29| 1.4| 5 – 52| 4.0|
5 – 52| 5.0| 5 – 14
VSPm – MK 3/5| 1.1| 1.5| 7.8 A| 10 – 80| 85 – 48| 2.3| 5 – 52| 4.0|
5 – 72| 8.3| 5 – 13
VSPm – MK 3/6| 1.5| 2| 9.0 A| 10 – 80| 101 – 56| 2.7| 5 – 53| 4.0|
5 – 65| 9.7| 5 – 19
VSPm – MK 5/4| 0.75| 1| 6.4 A| 20 – 120| 55 – 20| 1.5| 5 – 101|
4.0| 5 – 82| 5.3| 5 – 26
VSPm – MK 5/5| 1.1| 1.5| 6.5 A| 20 – 120| 69 – 21.5| 1.8| 5 – 108|
4.0| 5 – 99| 6.7| 5 – 13
VSPm – MK 5/7| 1.5| 2| 9.0 A| 20 – 120| 95 – 30| 2.6| 5 – 109| 4.0|
5 – 111| 9.3| 5 – 16
VSPm – MK 8/4| 1.1| 1.5| 8.3 A| 40 – 180| 53 – 12| 1.4| 5 – 175|
4.0| 5 – 115| 5.2| 5 – 30
VSPm – MK 8/5| 1.5| 2| 10.0 A| 40 – 180| 68 – 15.5| 1.8| 5 – 175|
4.0| 5 – 138| 6.6| 5 – 45
TYPE
Three-phase
| POWER
P2
| ABSORPTION
400 V
| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q
litres/min
| H
metres
| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSP – MK 3/3| 0.75| 1| 1.7 A| 10 – 80| 52 – 29| 1.4| 5 – 52| 4.0|
5 – 52| 5.0| 5 – 14
VSP – MK 3/5| 1.1| 1.5| 2.3 A| 10 – 80| 85 – 48| 2.3| 5 – 52| 4.0|
5 – 72| 8.3| 5 – 13
VSP – MK 3/6| 1.5| 2| 2.8 A| 10 – 80| 101 – 56| 2.7| 5 – 53| 4.0|
5 – 65| 9.7| 5 – 19
VSP – MK 5/4| 0.75| 1| 2.0 A| 20 – 120| 55 – 20| 1.5| 5 – 101| 4.0|
5 – 82| 5.3| 5 – 26
VSP – MK 5/5| 1.1| 1.5| 2.2 A| 20 – 120| 69 – 21.5| 1.8| 5 – 108|
4.0| 5 – 99| 6.7| 5 – 13
VSP – MK 5/7| 1.5| 2| 3.0 A| 20 – 120| 95 – 30| 2.6| 5 – 109| 4.0|
5 – 111| 9.3| 5 – 16
VSP – MK 5/8| 2.2| 3| 3.5 A| 20 – 120| 108 – 34| 2.9| 5 – 109| 4.0|
5 – 115| 10.6| 5 – 14
VSP – MK 8/4| 1.1| 1.5| 2.8 A| 40 – 180| 53 – 12| 1.4| 5 – 175|
4.0| 5 – 115| 5.2| 5 – 30
VSP – MK 8/5| 1.5| 2| 3.4 A| 40 – 180| 68 – 15.5| 1.8| 5 – 175|
4.0| 5 – 138| 6.6| 5 – 45
VSP – MK 8/6| 2.2| 3| 3.8 A| 40 – 180| 81 – 18.5| 2.2| 5 – 175|
4.0| 5 – 149| 8.0| 5 – 22
PERFORMANCE CURVES
DIMENSIONS AND WEIGHT
TYPE | PORTS | DIMENSIONS mm | kg |
---|---|---|---|
Single-phase | Three-phase | DN1 | DN2 |
n1 | n2 | S1 | s2 |
VSPm – MK 3/3 | VSP – MK 3/3 | **** |
1¼”
| ****
1″
| ****
93
| ****
255
| 447| ****
41
| 132| ****
242
| ****
113
| ****
129
| ****
143
| ****
146
| ****
14.5
| ****
10
| 23.3| 23.3
VSPm – MK 3/5| VSP – MK 3/5| 501| 186| 25.5| 25.5
VSPm – MK 3/6| VSP – MK 3/6| 528| 213| 27.3| 27.3
VSPm – MK 5/4| VSP – MK 5/4| 474| 159| 23.8| 23.8
VSPm – MK 5/5| VSP – MK 5/5| 501| 186| 25.2| 25.2
VSPm – MK 5/7| VSP – MK 5/7| 555| 240| 28.3| 28.3
–| VSP – MK 5/8| 602| 267| –| 28.6
VSPm – MK 8/4| VSP – MK 8/4| 474| 159| 26.6| 26.6
VSPm – MK 8/5| VSP – MK 8/5| 501| 186| 27.0| 27.0
–| VSP – MK 8/6| 548| 213| –| 29.4
PERFORMANCE RANGE
TECHNICAL DATA
TYPE
Single-phase
| POWER
P2
| ABSORPTION
230 V
| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q
litres/min
| H
metres
| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSPm – HT 3/4 PRO| 0.75| 1| 7.5 A| 5 – 90| 65 – 35| 1.6| 5 – 59|
4.0| 5 – 73| 5.9| 5 – 19
VSPm – HT 3/5 PRO| 1.1| 1.5| 9.0 A| 5 – 90| 80 – 44| 2.0| 5 – 62|
4.0| 5 – 86| 7.4| 5 – 22
VSPm – HT 3/6 PRO| 1.5| 2| 10.5 A| 5 – 90| 96 – 52| 2.4| 5 – 62|
4.0| 5 – 84| 8.8| 5 – 20
VSPm – HT 5/2 PRO| 0.75| 1| 7.0 A| 5 – 130| 35 – 20.5| 0.8| 5 – 83|
2.0| 5 – 114| 3.1| 5 – 22
VSPm – HT 5/3 PRO| 1.1| 1.5| 8.0 A| 5 – 130| 51.5 – 31| 1.3| 5 – 91|
4.0| 5 – 71| 4.8| 5 – 14
VSPm – HT 5/4 PRO| 1.5| 2| 9.5 A| 5 – 130| 68.5 – 41| 1.7| 5 – 90|
4.0| 5 – 108| 6.1| 5 – 26
VSPm – HT 8/3 PRO| 1.1| 1.5| 8.5 A| 20 – 200| 46.5 – 17| 1.1| 5 – 182|
4.0| 5 – 58| 4.1| 5 – 28
VSPm – HT 8/4 PRO| 1.5| 2| 10.0 A| 20 – 200| 62 – 23| 1.5| 5 – 180|
4.0| 5 – 128| 5.4| 5 – 48
TYPE
Three-phase
| POWER
P2
| ABSORPTION
400 V
| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q
litres/min
| H
metres
| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSP – HT 3/4 PRO| 0.75| 1| 2.5 A| 5 – 90| 65 – 35| 1.6| 5 – 59|
4.0| 5 – 73| 5.9| 5 – 19
VSP – HT 3/5 PRO| 1.1| 1.5| 3.0 A| 5 – 90| 80 – 44| 2.0| 5 – 62|
4.0| 5 – 86| 7.4| 5 – 22
VSP – HT 3/6 PRO| 1.5| 2| 3.5 A| 5 – 90| 96 – 52| 2.4| 5 – 62| 4.0|
5 – 84| 8.8| 5 – 20
VSP – HT 3/7 PRO| 1.8| 2.5| 4.2 A| 5 – 90| 112 – 61| 2.8| 5 – 62|
4.0| 5 – 76| 10.2| 5 – 25
VSP – HT 5/2 PRO| 0.75| 1| 2.3 A| 5 – 130| 35 – 20.5| 0.8| 5 – 83|
2.0| 5 – 114| 3.1| 5 – 22
VSP – HT 5/3 PRO| 1.1| 1.5| 2.4 A| 5 – 130| 51.5 – 31| 1.3| 5 – 91|
4.0| 5 – 71| 4.8| 5 – 14
VSP – HT 5/4 PRO| 1.5| 2| 3.2 A| 5 – 130| 68.5 – 41| 1.7| 5 – 90|
4.0| 5 – 108| 6.1| 5 – 26
VSP – HT 5/5 PRO| 1.8| 2.5| 4.0 A| 5 – 130| 85 – 51.5| 2.1| 5 – 91|
4.0| 5 – 128| 7.5| 5 – 42
VSP – HT 5/6 PRO| 2.2| 3| 4.3 A| 5 – 130| 103 – 62| 2.6| 5 – 92|
4.0| 5 – 118| 9.3| 5 – 25
VSP – HT 8/3 PRO| 1.1| 1.5| 3.0 A| 20 – 200| 46.5 – 17| 1.1| 5 – 182|
4.0| 5 – 58| 4.1| 5 – 28
VSP – HT 8/4 PRO| 1.5| 2| 3.4 A| 20 – 200| 62 – 23| 1.5| 5 – 180|
4.0| 5 – 128| 5.4| 5 – 48
VSP – HT 8/5 PRO| 1.8| 2.5| 4.0 A| 20 – 200| 77.5 – 28.5| 1.8| 5 – 181|
4.0| 5 – 156| 6.7| 5 – 44
VSP – HT 8/6 PRO| 2.2| 3| 4.5 A| 20 – 200| 93 – 34.5| 2.3| 5 – 186|
4.0| 5 – 179| 8.2| 5 – 32
PERFORMANCE CURVES
PERFORMANCE CURVES
DIMENSIONS AND WEIGHT
TYPE | PORTS | DIMENSIONS mm | kg |
---|---|---|---|
Single-phase | Three-phase | DN1 | DN2 |
1~ | 3~ | ||
VSPm – HT 3/4 PRO | VSP – HT 3/4 PRO | **** |
1″
| ****
1″
| ****
164
| ****
269
| ****
212
| ****
15
| 509| ****
75
| ****
100
| ****
180
| ****
Ø 13
| 35.3| 34.8
VSPm – HT 3/5 PRO| VSP – HT 3/5 PRO| 535| 35.5| 35.0
VSPm – HT 3/6 PRO| VSP – HT 3/6 PRO| 561| 36.2| 37.1
–| VSP – HT 3/7 PRO| 607| –| 41.2
VSPm – HT 5/2 PRO| VSP – HT 5/2 PRO| ****
1¼”
| ****
1¼”
| 457| 33.2| 33.2
VSPm – HT 5/3 PRO| VSP – HT 5/3 PRO| 483| 33.4| 33.4
VSPm – HT 5/4 PRO| VSP – HT 5/4 PRO| 509| 35.3| 35.4
–| VSP – HT 5/5 PRO| 555| –| 39.1
–| VSP – HT 5/6 PRO| 581| –| 40.1
VSPm – HT 8/3 PRO| VSP – HT 8/3 PRO| ****
1½”
| ****
1½”
| ****
240
| 488| ****
80
| 33.9| 33.9
VSPm – HT 8/4 PRO| VSP – HT 8/4 PRO| 514| 35.8| 35.9
–| VSP – HT 8/5 PRO| 560| –| 39.4
–| VSP – HT 8/6 PRO| 586| –| 40.2
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>