VSP 50Hz Pumps with inverters Instructions

July 18, 2024
VSP

VSP 50Hz Pumps with inverters

Product Information

Specifications

  • Product Name: VSP Pumps with Inverters
  • Application: Clean water for domestic use, civil use
  • Features:
    • Integrated frequency converter
    • Equipped with a pressure sensor for constant pressure
    • Easy installation, configuration, and adjustment
    • PFC technology for maintaining hydraulic performance
    • Integrated protection against various faults

Product Usage Instructions

Installation

VSP is suitable for residential and commercial use. Follow these steps for installation:

  1. Choose a suitable location for the unit.
  2. Connect the pump to the water supply line.
  3. Connect the electrical panel to a power source.
  4. Ensure proper grounding of the unit.

Configuration

The system comes ready to use, but advanced users can access an advanced menu for modifying factory parameters:

  1. Adjust the working pressure using the display and keypad.
  2. View operating parameters and alarm messages via the electrical panel.
  3. For advanced settings, access the guided procedure in the advanced menu.

Operation

To operate the VSP pumping unit:

  1. Use the arrow keys for navigation.
  2. Press ESC to exit menus.
  3. Toggle ON/OFF using the button provided.
  4. Confirm actions using the OK button.

Frequently Asked Questions

  • Q: What is the purpose of the integrated frequency converter in the VSP?
    • A: The integrated frequency converter ensures constant pressure as the system’s water demand fluctuates, providing efficient water supply and pressure boosting.
  • Q: How can I access the advanced menu for modifying the factory parameters?
    • A: Users can access the advanced menu through a guided procedure on the electrical panel for adapting to specific plant conditions.

INSTALLATION AND USE

VSP is a versatile pumping unit designed for various applications. It’s ideal for residential and commercial use, providing water supply and pressure boosting.
VSP seamlessly integrates with any pressurization system, including existing ones, ensuring maximum comfort and enabling significant energy savings.

PRODUCT DESCRIPTION

VSP is a system comprising a pump and an integrated frequency converter. Equipped with a pressure sensor, it ensures constant pressure as the system’s water demand fluctuates. This ready-to-use product eliminates the need for configuration procedures. Users can adjust the working pressure and view operating parameters and alarm messages via the electrical panel. For advanced users, the system offers access to an advanced menu for modifying factory parameters through a guided procedure, allowing adaptation to specific plant conditions.

VSP is an intelligent pumping unit, equipped with:

  • display and keypad allowing simple and intuitive configuration and reading of operating parameters;
  • interface ports for additional analogue and digital input and output signals;
  • PFC technology maintains hydraulic performance unaffected even when supply voltages vary within ±20% of the nominal value;
  • RS 485 communication for connection to a second device in parallel.

Integrated protection against:

  • dry running
  • overcurrent
  • overvoltage and undervoltage
  • combustion chamber
  • short circuit
  • lack of phases in the connections (for three-phase version)

TECHNICAL DATA

  • Power supply:
  • 1~ 230V±10% or 3~ 400V±10%
  • Frequency: 50/60 Hz
  • Please refer to the technical data of the specific electro pumps for liquid temperature, ambient temperature, and protection degree.

KEY FEATURES

  • Easy installation, configuration, and adjustment.
  • Greater comfort, thanks to optimized performance and low noise levels.
  • Energy saving reduces startup and operating currents, ensuring.
  • Automatic compensation for fluctuations in the supply voltage.
  • Communication with another device to enhance system capabilities.
  • Intelligent management of control and intervention in case of anomalies.

ELECTRICAL PANEL

It enables access to configuration menus, navigation through settings, adjustment of operating parameters, and activation or deactivation of the pumping unit.

  1. Scroll arrow keys

  2. ESC menu exit key

  3. ON/OFF button

  4. Confirmation button

  5. 4-backlit display to indicate the operating status of the VSP
    DISPLAY SYMBOLS

  6. ALARM warning light

  7. AUTOMATIC operation indicator light

  8. MANUAL operation indicator light

  9. Indicator light for running pump no. 1

  10. Indicator light for running pump no. 2 (if present)

  11. WI-FI active indicator light (if present)

  12. Alphanumeric display with 2 lines for visualization of: voltage, frequency, current, power factor (cosφ), pressure, level, system operating status, system anomalies.

  13. VSP operating status LED lights

TYPICAL INSTALLATION

PERFORMANCE RANGE

TECHNICAL DATA

TYPE


Single-phase

| POWER

P2

| ABSORPTION

230 V

| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q

litres/min

| H

metres

| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSPm – FCR 75/90| 1.5| 2| 9.8 A| 5 – 90| 71.5 – 43.5| 1.9| 5 – 60| 4.0| 5 – 86| 7.0| 5 – 16
VSPm – FCR 80/130| 1.5| 2| 9.8 A| 5 – 130| 74.5 – 30| 2.0| 5 – 107| 4.0| 5 – 107| 7.3| 5 – 22
VSPm – FCR 70/200| 1.5| 2| 9.8 A| 5 – 200| 65.5 – 21| 1.8| 5 – 180| 4.0| 5 – 115| 6.4| 5 – 36
TYPE


Three-phase

| POWER

P2

| ABSORPTION

400 V

| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q

litres/min

| H

metres

| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSP – FCR 75/90| 1.5| 2| 3.6 A| 5 – 90| 71.5 – 43.5| 1.9| 5 – 60| 4.0| 5 – 86| 7.0| 5 – 16
VSP – FCR 100/90| 2.2| 3| 4.9 A| 5 – 90| 94 – 62.5| 2.5| 5 – 58| 4.0| 5 – 71| 9.2| 5 – 20
VSP – FCR 80/130| 1.5| 2| 3.6 A| 5 – 130| 74.5 – 30| 2.0| 5 – 107| 4.0| 5 – 107| 7.3| 5 – 22
VSP – FCR 105/130| 2.2| 3| 4.9 A| 5 – 130| 98 – 57.5| 2.7| 5 – 90| 4.0| 5 – 107| 9.6| 5 – 30
VSP – FCR 70/200| 1.5| 2| 3.6 A| 5 – 200| 65.5 – 21| 1.8| 5 – 180| 4.0| 5 – 115| 6.4| 5 – 36
VSP – FCR 95/200| 2.2| 3| 4.9 A| 5 – 200| 87.5 – 42| 2.4| 5 – 178| 4.0| 5 – 175| 8.6| 5 – 32

PERFORMANCE CURVES

DIMENSIONS AND WEIGHT

TYPE PORTS DIMENSIONS mm kg
Single-phase Three-phase DN1 DN2
n n1 s 1~
VSPm – FCR 75/90 VSP – FCR 75/90 ****




1¼”

| ****





1″

| ****

445

| ****







75

| ****

139

| ****







260

| ****







145

| ****







59

| ****







242

| ****







129

| ****







113

| ****







185

| ****







145

| ****







11

| ****

21.7

| ****

21.7

| VSP – FCR 100/90| ****

471

| ****

165

| ****

| ****

21.9

VSPm – FCR 80/130| VSP – FCR 80/130| ****

445

| ****

139

| ****

21.9

| ****

21.9

| VSP – FCR 105/130| ****

471

| ****

165

| ****

| ****

21.9

VSPm – FCR 70/200| VSP – FCR 70/200| ****

445

| ****

139

| ****

24.1

| ****

23.9

| VSP – FCR 95/200| ****

471

| ****

165

| ****

| ****

24.0

PERFORMANCE RANGE

TECHNICAL DATA

TYPE


Single-phase

| POWER

P2

| ABSORPTION

230 V

| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q

litres/min

| H

metres

| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSPm – PLURIJET 75/90| 1.5| 2| 9.8 A| 5 – 90| 71.5 – 43.5| 1.9| 5 – 60| 4.0| 5 – 86| 7.0| 5 – 16
VSPm – PLURIJET 80/130| 1.5| 2| 9.8 A| 5 – 130| 74.5 – 30| 2.0| 5 – 107| 4.0| 5 – 107| 7.3| 5 – 22
VSPm – PLURIJET 70/200| 1.5| 2| 9.8 A| 5 – 200| 65.5 – 21| 1.8| 5 – 180| 4.0| 5 – 115| 6.4| 5 – 36
TYPE


Three-phase

| POWER

P2

| ABSORPTION

400 V

| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q

litres/min

| H

metres

| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSP – PLURIJET 75/90| 1.5| 2| 3.6 A| 5 – 90| 71.5 – 43.5| 1.9| 5 – 60| 4.0| 5 – 86| 7.0| 5 – 16
VSP – PLURIJET 100/90| 2.2| 3| 4.9 A| 5 – 90| 94 – 62.5| 2.5| 5 – 58| 4.0| 5 – 71| 9.2| 5 – 20
VSP – PLURIJET 80/130| 1.5| 2| 3.6 A| 5 – 130| 74.5 – 30| 2.0| 5 – 107| 4.0| 5 – 107| 7.3| 5 – 22
VSP – PLURIJET 105/130| 2.2| 3| 4.9 A| 5 – 130| 98 – 57.5| 2.7| 5 – 90| 4.0| 5 – 107| 9.6| 5 – 30
VSP – PLURIJET 70/200| 1.5| 2| 3.6 A| 5 – 200| 65.5 – 21| 1.8| 5 – 180| 4.0| 5 – 115| 6.4| 5 – 36
VSP – PLURIJET 95/200| 2.2| 3| 4.9 A| 5 – 200| 87.5 – 42| 2.4| 5 – 178| 4.0| 5 – 175| 8.6| 5 – 32

PERFORMANCE CURVES

DIMENSIONS AND WEIGHT

TYPE PORTS DIMENSIONS mm kg
Single-phase Three-phase DN1 DN2
n n1 s 1~
VSPm – PLURIJET 75/90 VSP – PLURIJET 75/90 ****




1¼”

| ****





1″

| ****

497

| ****







75

| ****

191

| ****







260

| ****







145

| ****







59

| ****







242

| ****







129

| ****







113

| ****







185

| ****







145

| ****







11

| ****

21.7

| ****

21.7

| VSP – PLURIJET 100/90| ****

523

| ****

217

| ****

| ****

23.9

VSPm – PLURIJET 80/130| VSP – PLURIJET 80/130| ****

497

| ****

191

| ****

21.9

| ****

21.9

| VSP – PLURIJET 105/130| ****

523

| ****

217

| ****

| ****

24.1

VSPm – PLURIJET 70/200| VSP – PLURIJET 70/200| ****

497

| ****

191

| ****

21.9

| ****

21.9

| VSP – PLURIJET 95/200| ****

523

| ****

217

| ****

| ****

24.0

PERFORMANCE RANGE

TECHNICAL DATA

TYPE


Single-phase

| POWER

P2

| ABSORPTION

230 V

| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q

litres/min

| H

metres

| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSPm – MK 3/3| 0.75| 1| 6.2 A| 10 – 80| 52 – 29| 1.4| 5 – 52| 4.0| 5 – 52| 5.0| 5 – 14
VSPm – MK 3/5| 1.1| 1.5| 7.8 A| 10 – 80| 85 – 48| 2.3| 5 – 52| 4.0| 5 – 72| 8.3| 5 – 13
VSPm – MK 3/6| 1.5| 2| 9.0 A| 10 – 80| 101 – 56| 2.7| 5 – 53| 4.0| 5 – 65| 9.7| 5 – 19
VSPm – MK 5/4| 0.75| 1| 6.4 A| 20 – 120| 55 – 20| 1.5| 5 – 101| 4.0| 5 – 82| 5.3| 5 – 26
VSPm – MK 5/5| 1.1| 1.5| 6.5 A| 20 – 120| 69 – 21.5| 1.8| 5 – 108| 4.0| 5 – 99| 6.7| 5 – 13
VSPm – MK 5/7| 1.5| 2| 9.0 A| 20 – 120| 95 – 30| 2.6| 5 – 109| 4.0| 5 – 111| 9.3| 5 – 16
VSPm – MK 8/4| 1.1| 1.5| 8.3 A| 40 – 180| 53 – 12| 1.4| 5 – 175| 4.0| 5 – 115| 5.2| 5 – 30
VSPm – MK 8/5| 1.5| 2| 10.0 A| 40 – 180| 68 – 15.5| 1.8| 5 – 175| 4.0| 5 – 138| 6.6| 5 – 45
TYPE


Three-phase

| POWER

P2

| ABSORPTION

400 V

| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q

litres/min

| H

metres

| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSP – MK 3/3| 0.75| 1| 1.7 A| 10 – 80| 52 – 29| 1.4| 5 – 52| 4.0| 5 – 52| 5.0| 5 – 14
VSP – MK 3/5| 1.1| 1.5| 2.3 A| 10 – 80| 85 – 48| 2.3| 5 – 52| 4.0| 5 – 72| 8.3| 5 – 13
VSP – MK 3/6| 1.5| 2| 2.8 A| 10 – 80| 101 – 56| 2.7| 5 – 53| 4.0| 5 – 65| 9.7| 5 – 19
VSP – MK 5/4| 0.75| 1| 2.0 A| 20 – 120| 55 – 20| 1.5| 5 – 101| 4.0| 5 – 82| 5.3| 5 – 26
VSP – MK 5/5| 1.1| 1.5| 2.2 A| 20 – 120| 69 – 21.5| 1.8| 5 – 108| 4.0| 5 – 99| 6.7| 5 – 13
VSP – MK 5/7| 1.5| 2| 3.0 A| 20 – 120| 95 – 30| 2.6| 5 – 109| 4.0| 5 – 111| 9.3| 5 – 16
VSP – MK 5/8| 2.2| 3| 3.5 A| 20 – 120| 108 – 34| 2.9| 5 – 109| 4.0| 5 – 115| 10.6| 5 – 14
VSP – MK 8/4| 1.1| 1.5| 2.8 A| 40 – 180| 53 – 12| 1.4| 5 – 175| 4.0| 5 – 115| 5.2| 5 – 30
VSP – MK 8/5| 1.5| 2| 3.4 A| 40 – 180| 68 – 15.5| 1.8| 5 – 175| 4.0| 5 – 138| 6.6| 5 – 45
VSP – MK 8/6| 2.2| 3| 3.8 A| 40 – 180| 81 – 18.5| 2.2| 5 – 175| 4.0| 5 – 149| 8.0| 5 – 22

PERFORMANCE CURVES

DIMENSIONS AND WEIGHT

TYPE PORTS DIMENSIONS mm kg
Single-phase Three-phase DN1 DN2
n1 n2 S1 s2
VSPm – MK 3/3 VSP – MK 3/3 ****






1¼”

| ****







1″

| ****








93

| ****








255

| 447| ****








41

| 132| ****








242

| ****








113

| ****








129

| ****








143

| ****








146

| ****








14.5

| ****








10

| 23.3| 23.3
VSPm – MK 3/5| VSP – MK 3/5| 501| 186| 25.5| 25.5
VSPm – MK 3/6| VSP – MK 3/6| 528| 213| 27.3| 27.3
VSPm – MK 5/4| VSP – MK 5/4| 474| 159| 23.8| 23.8
VSPm – MK 5/5| VSP – MK 5/5| 501| 186| 25.2| 25.2
VSPm – MK 5/7| VSP – MK 5/7| 555| 240| 28.3| 28.3
| VSP – MK 5/8| 602| 267| –| 28.6
VSPm – MK 8/4| VSP – MK 8/4| 474| 159| 26.6| 26.6
VSPm – MK 8/5| VSP – MK 8/5| 501| 186| 27.0| 27.0
| VSP – MK 8/6| 548| 213| –| 29.4

PERFORMANCE RANGE

TECHNICAL DATA

TYPE


Single-phase

| POWER

P2

| ABSORPTION

230 V

| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q

litres/min

| H

metres

| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSPm – HT 3/4 PRO| 0.75| 1| 7.5 A| 5 – 90| 65 – 35| 1.6| 5 – 59| 4.0| 5 – 73| 5.9| 5 – 19
VSPm – HT 3/5 PRO| 1.1| 1.5| 9.0 A| 5 – 90| 80 – 44| 2.0| 5 – 62| 4.0| 5 – 86| 7.4| 5 – 22
VSPm – HT 3/6 PRO| 1.5| 2| 10.5 A| 5 – 90| 96 – 52| 2.4| 5 – 62| 4.0| 5 – 84| 8.8| 5 – 20
VSPm – HT 5/2 PRO| 0.75| 1| 7.0 A| 5 – 130| 35 – 20.5| 0.8| 5 – 83| 2.0| 5 – 114| 3.1| 5 – 22
VSPm – HT 5/3 PRO| 1.1| 1.5| 8.0 A| 5 – 130| 51.5 – 31| 1.3| 5 – 91| 4.0| 5 – 71| 4.8| 5 – 14
VSPm – HT 5/4 PRO| 1.5| 2| 9.5 A| 5 – 130| 68.5 – 41| 1.7| 5 – 90| 4.0| 5 – 108| 6.1| 5 – 26
VSPm – HT 8/3 PRO| 1.1| 1.5| 8.5 A| 20 – 200| 46.5 – 17| 1.1| 5 – 182| 4.0| 5 – 58| 4.1| 5 – 28
VSPm – HT 8/4 PRO| 1.5| 2| 10.0 A| 20 – 200| 62 – 23| 1.5| 5 – 180| 4.0| 5 – 128| 5.4| 5 – 48
TYPE


Three-phase

| POWER

P2

| ABSORPTION

400 V

| PERFORMANCE| PERFORMANCE (ADJUSTABLE SET POINT)
---|---|---|---|---
Q

litres/min

| H

metres

| Set Point Min| Set Point Calibration Std| Set Point Max
kW| HP| bar| l/min| bar| l/min| bar| l/min
VSP – HT 3/4 PRO| 0.75| 1| 2.5 A| 5 – 90| 65 – 35| 1.6| 5 – 59| 4.0| 5 – 73| 5.9| 5 – 19
VSP – HT 3/5 PRO| 1.1| 1.5| 3.0 A| 5 – 90| 80 – 44| 2.0| 5 – 62| 4.0| 5 – 86| 7.4| 5 – 22
VSP – HT 3/6 PRO| 1.5| 2| 3.5 A| 5 – 90| 96 – 52| 2.4| 5 – 62| 4.0| 5 – 84| 8.8| 5 – 20
VSP – HT 3/7 PRO| 1.8| 2.5| 4.2 A| 5 – 90| 112 – 61| 2.8| 5 – 62| 4.0| 5 – 76| 10.2| 5 – 25
VSP – HT 5/2 PRO| 0.75| 1| 2.3 A| 5 – 130| 35 – 20.5| 0.8| 5 – 83| 2.0| 5 – 114| 3.1| 5 – 22
VSP – HT 5/3 PRO| 1.1| 1.5| 2.4 A| 5 – 130| 51.5 – 31| 1.3| 5 – 91| 4.0| 5 – 71| 4.8| 5 – 14
VSP – HT 5/4 PRO| 1.5| 2| 3.2 A| 5 – 130| 68.5 – 41| 1.7| 5 – 90| 4.0| 5 – 108| 6.1| 5 – 26
VSP – HT 5/5 PRO| 1.8| 2.5| 4.0 A| 5 – 130| 85 – 51.5| 2.1| 5 – 91| 4.0| 5 – 128| 7.5| 5 – 42
VSP – HT 5/6 PRO| 2.2| 3| 4.3 A| 5 – 130| 103 – 62| 2.6| 5 – 92| 4.0| 5 – 118| 9.3| 5 – 25
VSP – HT 8/3 PRO| 1.1| 1.5| 3.0 A| 20 – 200| 46.5 – 17| 1.1| 5 – 182| 4.0| 5 – 58| 4.1| 5 – 28
VSP – HT 8/4 PRO| 1.5| 2| 3.4 A| 20 – 200| 62 – 23| 1.5| 5 – 180| 4.0| 5 – 128| 5.4| 5 – 48
VSP – HT 8/5 PRO| 1.8| 2.5| 4.0 A| 20 – 200| 77.5 – 28.5| 1.8| 5 – 181| 4.0| 5 – 156| 6.7| 5 – 44
VSP – HT 8/6 PRO| 2.2| 3| 4.5 A| 20 – 200| 93 – 34.5| 2.3| 5 – 186| 4.0| 5 – 179| 8.2| 5 – 32

PERFORMANCE CURVES

PERFORMANCE CURVES


DIMENSIONS AND WEIGHT

TYPE PORTS DIMENSIONS mm kg
Single-phase Three-phase DN1 DN2
1~ 3~
VSPm – HT 3/4 PRO VSP – HT 3/4 PRO ****

1″

| ****

1″

| ****








164

| ****








269

| ****





212

| ****








15

| 509| ****





75

| ****








100

| ****








180

| ****








Ø 13

| 35.3| 34.8
VSPm – HT 3/5 PRO| VSP – HT 3/5 PRO| 535| 35.5| 35.0
VSPm – HT 3/6 PRO| VSP – HT 3/6 PRO| 561| 36.2| 37.1
| VSP – HT 3/7 PRO| 607| –| 41.2
VSPm – HT 5/2 PRO| VSP – HT 5/2 PRO| ****


1¼”

| ****


1¼”

| 457| 33.2| 33.2
VSPm – HT 5/3 PRO| VSP – HT 5/3 PRO| 483| 33.4| 33.4
VSPm – HT 5/4 PRO| VSP – HT 5/4 PRO| 509| 35.3| 35.4
| VSP – HT 5/5 PRO| 555| –| 39.1
| VSP – HT 5/6 PRO| 581| –| 40.1
VSPm – HT 8/3 PRO| VSP – HT 8/3 PRO| ****

1½”

| ****

1½”

| ****


240

| 488| ****


80

| 33.9| 33.9
VSPm – HT 8/4 PRO| VSP – HT 8/4 PRO| 514| 35.8| 35.9
| VSP – HT 8/5 PRO| 560| –| 39.4
| VSP – HT 8/6 PRO| 586| –| 40.2

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals