MEGA LITE Obra Flood N180 User Manual
- June 6, 2024
- MEGA LITE
Table of Contents
- Obra Flood N180
- Technical Information
- Mechanical Specifications
- Electrical Specifications
- Control & Programming
- Photometrics
- Main Power Connection
- DMX Profile
- Obra Flood N180 10 Channel Mode
- Main Control Menu
- Size and Weight
- Rigging the fixture
- Instructions;
- Cleaning and Maintenance
- Parts List
- Warranty Information
Obra Flood N180
User Manual
Check that the unit has not been damaged during transport
Read all caution and warnings prior to all operation of this equipment
Protection Against Fire
- Maintain a minimum of 1 foot distance from any type of flame.
- Replace fuse only with the specified type and rating.
- Do Not install the unit to close to a heat source.
- Make sure cable are properly secured
- Maximum surface operating temperature 140°.
Protection Against Electrical Fire
- Disconnect power before servicing.
- For connection to main power supply proceed to page 6.
- This unit must be earthed. (electronically grounded) 4. This fixture must not be left on for long periods of time.
Protection Against Mechanical Hazards
- Use safety chain when hanging unit.
- Use quality clamps or bolts when positioning unit
- Do not open unit while it is on, risk of electrical shock.
Technical Information
Part Numbers
Fixture
!tom # 4348-0bra Flood N180
Mechanical Specifications
- Signal Connectors: Panel Mounted 5-pin XLR connectors in/out
- Power Connectors: Panel Mount Power Con type in/out connection (Nema 5-15 to Blue power male cable included)
- Thermal: Maximum ambient temperature 40° C Maximum surface temperature 60° C
- Display: Digital Fastening System: Accessory clamp fixture track mounts
- Lens Angle: 97°
- Barndoors: Included
- Diffuser: Included
Electrical Specifications
- LED Type: 60 single color LEDs
- Color Type: Dark Red, Red, Fire Red, Green, Aqua, Lime, Blue, Indigo, Amber
- CRI: 62 on all colors on
- CCT: 10809K @ full
- LED Watts: 3 Watts each
- Power Consumption: Universal 100 – 240V 50/60 Hz
- Ballast: Electronic
- Watts: 152W
- Current: 1.26A PF: 1.0
Control & Programming
-
Protocol: DMX 512
-
RDM: Yes
-
DMX Channels: 4 Mode of Operation
Mode 4 Channel=Red (Dark Red, Red, Fire Red), Green (Green, Aqua, Lime) Blue, Indigo, Amber Mode 9 Channel= Dark Red, Red, Fire Red, Green, Aqua, Lime, Blue, Indigo, Amber Mode 10 Channel= Dimmer, Dark Red, Red, Fire Red, Green, Aqua, Lime, Blue, Indigo, Amber Mode 14 Channel=Dimmer, Dark Red, Red, Fire Red, Green, Aqua, Lime, Blue, Indigo, Amber, Strobe, Macro, Macro Speed, Dimmer Speed -
Operating Mode: Stand alone 255 step dimmer setting via display Auto preprogram via display
Photometrics
Output at full
Lumens at full output: Efficacy
1,380: 131mIW
- CCT: 10809K
- Duv: -0.0172
- CRI (Ra): 62
- TM-30 (Rf): 74
- TM-30 (Rg): 113
Spectrum
CRI Samples
Main Power Connection
Caution!
- Do not connect fixture to a dimmer system.
- This unit has Auto switching power supply. It will respond to 110V or 220V automatically
- This unit must be earthed. (electronically grounded)
- Replace fuse only with the specified type and rating.
The occupation of the connection-cable is as follows:
This fixture is equipped with an electronic power supply that will let the unit operate from 100V to 240V from 50Hz to 60Hz
The fixture is equipped with 5 pin XLR cable mounted sockets for DMX input and output. The sockets are wired in parallel. Only use a shielded twisted pair cable designed for RS-485 and 5 pin XLR plugs and connectors in order to connect the controller with the fixture or the fixture with another.
Caution! At the last fixture the DMX signal needs to be terminated with a terminator. Solder a 120 Ohm resistor between the (-) and the (+) signal into a 3 or 5 pin XLR plug and plug it in to the last fixture on the signal run. Pre-manufactured terminator plugs are available for purchase from your Mega- Lite dealer (P-DMXT).
DMX Profile
Obra Flood N180 4 Channel Mode
Obra Flood N180 9 Channel Mode
Obra Flood N180 10 Channel Mode
Obra Flood N180 14 Channel Mode
Note: For Strobe function to work Dimmer Speed needs to be engaged.
Main Control Menu
The control board on the fixture is your interface to access and control all the functions on the unit. Its digital display gives you a code view of the options and functions. The following will explain each function and its options.
Size and Weight
Size
12.75” x 5.33” x 11.75”
Packaged Size
15” x 12.5” x 8”
Weight
Net 14lb
Gross 15lb
Rigging the fixture
Caution!
- The installations must be carried out by an authorized dealer or trained professional.
- Unit may cause severe injures if you have doubts concerning the safety do not install.
- Unit is to be 24inches away from flammable materials (decoration material)
- Use high quality installation equipment to hang unit.
When rigging a unit it is very important that you follow common safety procedures. Rigging requires extensive experi-ence including but not limited to calculating working loads, material being used and periodic safety inspections. If you lack these qualifications, do not attempt the installation yourself, instead use a professional structural rigger.
When rigging the unit always be secured with a secondary safety attachment. The installation location of the fixture has got to be built in the way that it can hold 10 times the weight for 1 hour with out any harming.
Installation should be checked at least one time a year by a skilled person.
Instructions;
To add mounting hardware slide 2 Bolts head first to track in position 1,2 or 3. Add clamp mounting hardware then secure with 2 washers and nuts.
Please make sure all nuts are tight and secure
There is 3 mounting track positions for the clamp mount.
Cleaning and Maintenance
Installation Maintenance: The operator has to make sure that the unit is operating safely and has the installations and electronics checked by an expert every 2 years.
The following points have to be considered during the inspection:
- All screws used for installing the device or part of the device have to be tightly connected and must not be corroded.
- There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing).
- The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed.
Note: There is no serviceable parts inside the device except for the LED’s. Maintenance and service operations are to be carried out by authorized dealers.
Replacing the fuse: When possible only replace the fuse with the same type and rating.
Replacing the power cable: If the power cable of this device becomes damaged, it has to be replaced by authorized dealers or trained professional only.
Should you have further questions , please contact your dealer.
Parts List
Warranty Information
Warranty Conditions
- Unless otherwise stated in writing, your product is covered by a one year parts and labor limited warranty.
- LED’s and LAMPS are not guaranteed to match in color temperature or output.
- It is the owner’s responsibility to furnish receipts or invoices for verification of purchase, date, and reseller or distributor. If purchase date cannot be provided, date of manufacture will be used to determine warranty period.
- Goods returned under warranty must follow the proper authorization procedure and must be accompanied by a copy of the original invoice.
- Goods repaired under warranty will be returned to the owner with the freight prepaid by MSI via the most economical means of shipment.
- Repair or replacement as provided for under this warranty is the exclusive remedy of the consumer. MEGA SYSTEMSINC. makes no warranties, express or implied, with respect to any product, and Mega Systems specifically disclaims any warranty of merchantability or fitness for a particular purpose. Mega Systems shall not be liable for any indirect, incidental or consequential damage, including lost profit, sustained or incurred in connection with any product or caused byproduct defect or the partial or total failure of any product regardless of the form of action, weather in contract, tort(including negligence), strict liability or otherwise, and weather or not such damage was foreseen or unforeseen.
- Warranty is void if the product is misused, damaged, modified in any way, or for unauthorized repairs or parts. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Customer Support
Mega Lite has a customer support line to provide set up help and to answer any
question should you encounter a problem. Please visit our website for any
other related technical documents. For service related issue please contact
our service dept.
Monday—Friday 9am to 6pm CST
Voice: 210-684-2600
E-mail: service@mega.lighting
Manual Version
Please Visit www.mega.lighting for the most up to
date manual version
ocument Version
Date: 10/08/2019
Fixture: 1.1
Software:V1.1
Mega-Lite
18668 Highway 16N
Helotes, Texas 78023
Ph 210-684-2600 Fax
210-855-6279
www.mega.lighting / info@mega.lighting