PERFORMANCE RANGE

  • Flow rate up to 750 l/min (45 m3/h)
  • Head up to 15.5 m

INSTALLATION AND USE

VX pumps are renowned for their reliability, especially in automated fixed installations.
Ideal for domestic, civil, and industrial settings, they efficiently handle suspended solids up to 50 mm in diameter, including in groundwater, surface water, and sewage.
They are also perfect for pumping out flooded areas like basements, underground parking garages, car wash stations, and emptying septic tanks and sewage systems.

The VORTEX impeller can handle solids up to 50 mm in diameter. Its unique design ensures safe operation against clogging.

INCLUDES

  • Power cable length:
    • 5 m for VX 8 and VX 10
    • 10 m for VX 15 and VX 20
  • Float switch (exclusive to single-phase models)

APPLICATION LIMITS

  • Depth below water level up to 5 m (with an appropriately sized power cable)
  • Liquid temperature up to +40 °C
  • Suspended solids transfer:
    • up to Ø 40 mm for VX /35
    • up to Ø 50 mm for VX /50
  • Minimum immersion for continuous service:
    • 290 mm for VX 8 and VX 10
    • 330 mm for VX 15
    • 360 mm for VX 20

AVAILABLE UPON REQUEST

  • Pumps with 10 m power cable for VX 8 and VX 10
  • Different voltage requirements 60 Hz frequency

PATENTS – TRADE MARKS – MODELS

  • Patent No. EP2313658
  • Patent No. IT0001428923

CURVES AND PERFORMANCE DATA

TYPE| POWER (P2)| Q| m³/h| 0| 3| 6| 12| 18| 24| 27| 30| 33| 36| 39| 45
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Single- phase| Three- phase| kW| HP| l/min| 0| 50| 100| 200| 300| 400| 450| 500| 550| 600| 650| 750
VXm 8/50| VX 8/50| 0.55| 0.75|

H metres

| 6.5| 6| 5.8| 5| 4| 2.5| 1.5|  |  |  |  |
VXm 10/50| VX 10/50| 0.75| 1| 9| 8.5| 8.2| 7.5| 6.5| 5| 3.8| 2.5| 1.5|  |  |
VXm 15/50| VX 15/50| 1.1| 1.5| 11.5| 11| 10.5| 9.8| 8.7| 7.5| 6.5| 5.5| 4.5| 3.5| 2|
VXm 20/50| VX 20/50| 1.5| 2| 13.5| 13| 12.5| 11.5| 10.7| 9.5| 9| 8| 7.5| 6.5| 5| 2.5

Technical data

ABSORPTION

TYPE

Single- phase

| VOLTAGE

230 V

---|---
VXm 8/35| 4.3 A
VXm 10/35| 5.5 A
VXm 15/35| 7.0 A
VXm 20/35| 9.6 A
VXm 8/50| 4.3 A
VXm 10/50| 5.5 A
VXm 15/50| 7.0 A
VXm 20/50| 9.6 A
TYPE

Three- phase

| VOLTAGE

400 V

---|---
VX 8/35| 1.6 A
VX 10/35| 2.2 A
VX 15/35| 2.7 A
VX 20/35| 3.7 A
VX 8/50| 1.6 A
VX 10/50| 2.2 A
VX 15/50| 2.7 A
VX 20/50| 3.7 A

DIMENSIONS AND WEIGHT

PALLET CAPACITY

TYPE NO. OF PUMPS
Single- phase Three- phase
VXm 8/35 VX 8/35
VXm 10/35 VX 10/35
VXm 15/35 VX 15/35
VXm 20/35 VX 20/35
VXm 8/50 VX 8/50
VXm 10/50 VX 10/50
VXm 15/50 VX 15/50
VXm 20/50 VX 20/50