GERMAN POOL GPR-S700L Chimney Type Range Hood User Manual

July 17, 2024
GERMAN POOL

Chimney Type Range Hood
GPR-S700L
GPR-S900L
U S E R M A N U A L

 GPR-S700L Chimney Type Range Hood

Online Warranty Registration http://www.germanpool.com/warranty

Please read these instructions and warranty information carefully before use and keep them handy for future reference.
Please register your warranty information now!
For Warranty Terms & Conditions, please refer to the last page of this user manual.
Dear client,
We are sure that the purchase of our extractor hood will fully satisfy all of your needs.
Please read this instruction manual carefully in order to obtain the best results from the use of the hood.

Instructions for installation, maintenance and use

General indications

  • Before installing and using the hood, be sure that the voltage (V) and the frequency (Hz) indicated on the rating label match the voltage and frequency at the installation site.
  • The rating label and technical data are shown on the inside of the product.
  • For better performance in extracting fumes we advise that tubing installed should be of a diameter not less than 125/152 mm. We also advise using rigid PVC tubing.

Electrical Connection
Connect the cord to a socket, which must have a minimum contact opening distance of 3 mm. The manufacturer shall not be liable for failure to observe all safety regulations in force for the correct and normal operation of electrical parts.
Control Panel Five-button control panel
This panel is situated on the front of the extractor and includes:

  • 3 control switches for the motor (speed positions 1, 2 and 3) (ref. W)
  • Off button of the motor (ref. V)
  • On/off light of the motor (ref. T)
  • Light switch (ref. U)

Care & Maintenance

Cleaning the shell
Before any type of operation, always make sure that the electrical cord is disconnected and the switch is in the off position.
Clean the external part with a soft cloth and a mild, liquid detergent. Avoid using any abrasive cleaning products.
Changing the LED light
Before changing the LED light make sure that the electrical cord is disconnected and the switch is in the off position.
Remove the grease filter and replace the light with a LED light bulb no more powerful than that specified in the Technical Specifications. Place the filter in position.
Cleaning the grease filter
Depending on use, and at least once a month the grease filters should be disassembled and cleaned in a dishwasher or with hot soapy water.
If washed in a dishwasher, the filters should be placed in an upright position to prevent food remains from falling on them.
After rinsing and drying, replace the filters by following the steps for disassembly in reverse order.
The manufacturer/supplier assumes no liability for consequences of installation, maintenance and usage not specified in this user manual.
The active carbon filters (optional accessory) must be replaced periodically to work properly, at least once every three months (depending on the frequency with which the hood is used).
Valid Warranty Conditions

  • Show the warranty card specified date officially and sealed by the distributor. Otherwise all claims are inadmissible.
  • Fill in the warranty card upon obtaining the hood.

Important Cautions

  • Do not connect the hood to chimneys, ventilation pipes or hot air pipes. Before connecting any pipes, consult municipal ordinances on exhaust air and request permission from the person in charge of the building. Be sure there is adequate ventilation, even in cases where the hood is to be used simultaneously with another product.
  • Never leave frying food unattended since grease can overheat and catch fire. The risk of fire is even greater in the case of used oil.
  • Never use the hood in areas where devices with exhaust pipes connected to the outside are already operating unless perfect ventilation can be guaranteed.
  • To avoid the possibility of fire, adhere strictly to all of the recommendations included here and to the periodic cleaning of the grease filters.
  • During an electrostatic discharge (ESD) it is possible that the device will stop working. By switching the device OFF and ON the device will again work as intended. There is no risk and no risk will appear.
  • If the supply cord of this equipment is damaged, it must only be replaced by manufacturer or it’s service agent or similarly qualified person in order to avoid a hazard.
  • Never have a lighted flame under the extractor hood(to prevent accumulated soot from burning).
  • The appliance must be placed in such a way, that the supply plug is accessible.
  • The hood must be installed at a minimum distance of 65cm from the stove top.
  • During climatic conditions causing electrical interference, it is possible that the device may stop working. By switching the device OFF and ON the device will resume normal operation safely.
  • This hood is not designed to be used by people (including children) with reduced physical, sensorial or mental capacity, or who lack experience or knowledge about it, unless they have had supervision or instructions on how to use the hood by someone who is responsible for their safety.
  • For safety, children must be supervised to ensure that they do not play with the hood.
  • The evacuated air must not be sent along conduits that are used to evacuate smoke from devices powered by gas or other fuels (this does not apply to devices used exclusively to discharge air inside the room).
  • When the extractor hood is turned on along with other appliances powered by energy other than electricity, the air outlet must not be greater than 4 Pa (4×10-5 bar).
  • Never use the hood in places where appliances are already operating with outputs connected to the exterior unless perfect ventilation of the place can be ensured.
  • This hood can only be installed over electric or gas hobs with a maximum of 4 cooking points.
  • If the extractor hood is installed over a gas cooking appliance, the minimum distance between the surface supporting the cooking elements and the lower part of the hood must be at least 65 cm. If the installation instructions for the gas cooker indicate a greater distance, this should be observed.
  • If the extractor hood is installed over an electric cooking appliance, the minimum distance to be left between the surface supporting the cooking elements and the lower part of the hood is at least 65cm.
  • The regulations with respect to air evacuation must be respected.

All repairs specified by the warranty shall be conducted by our importers.
The manufacturer declares that this product meets all the essential requirements for low voltage electrical material set out in European directive 2006/95/EEC of 12 December 2006 and for electromagnetic compatibility as required by European directive 2004/108/ EEC of 15 December 2004.
If you need any technical help or would like more information about our products, please do not hesitate to contact our official distributor.
THE MANUFACTURER reserves the right to effect any technological improvement or modification without prior notice.

Technical Specifications

Model GPR-S700L GPR-S900L
Voltage / Frequency 220 V – 240 V/ 50 Hz
Power (Max) 257 W
Lighting 3.5 W x 2 (LED)
Rotating Method Single motor
Speed Selection 3 ( Turbo/ High/ Low )
Sound Level 55 dB – 69 dB
Exhaust Flow Max. 1,020 m3/hr
Dimensions (H) 785-1155 mm

(W) 700 mm
(D) 500 mm| (H) 785-1155 mm
(W) 900 mm
(D) 500 mm
Exhaust Outlet Diameter| 125mm/5″; 152mm/6″
Net Weight| 14 kg| 15 kg

Specifications are subject to change without prior notice.
If there is any inconsistency or ambiguity between the Chinese version and the English version, the English version shall prevail.
Refer to www.germanpool.com for the most up-to-date version of the User Manual.

Dimensions

Warranty Terms & Conditions

Under normal operations, the product will gurantee a 1-year full warranty provided by German Pool (effective from the date of purchase).

  • This warranty is not valid until customer registration information is received by our Service Centre within 10 days of purchase via one of the following means:

    1. Visit our website and register online: www.germanpool.com/warranty
    2. Complete all the fields on the attached Warranty Card and mail it back to our Customer Service Centre.

Please fill out the form below. This information and the original purchase invoice will be required for any repairs. Warranty will be invalidated if information provided is found to be inaccurate.
Model No. :
GPR-S700L
GPR-S900L
Serial No. :……………………………………
Purchased From :…………………………..
Invoice No. :…………………………………..
Purchase Date :……………………………….

  1. Customer who fails to present original purchase invoice will not be eligible for free warranty service.

  2. Customer should always follow the operating instructions. This warranty does not apply to:
    – labour costs for on-site installation, check-up, repair, replacement of parts and other transportation costs;
    – damages caused by accidents of any kind (including material transfer and others);
    – operating failures resulting from applying incorrect voltage, improper usage, and unauthorized installations or repairs.

  3. This warranty is invalid if:
    – the purchase invoice is modified by an unauthorized party;
    – the product is used for any commercial or industrial purposes;
    – the product is repaired or modified by unauthorized personnel, or unauthorized parts are installed;
    – the serial number is modified, damaged or removed from the product.

  4. German Pool will, at its discretion, repair or replace any  defective part.

  5. This warranty will be void if there is any transfer of ownership from the original purchaser.

Customer Service & Repair Centre

Hong Kong, China
10/F, Kowloon Godown
1-3 Kai Hing Road, Kowloon Bay, Kowloon, Hong Kong
Tel : +852 2333 6249
Fax : +852 2356 9798
Email : repairs@germanpool.com
Macau, China
3/F, Edificio Industrial Pou Fung, 145 Rua de Francisco Xavier Pereira, Macau
Tel : +853 2875 2699
Fax : +853 2875 2661
German Pool (Hong Kong) Limited

Hong Kong, China
Room 113, Newport Centre Phase II, 116 Ma Tau
Kok Road, Tokwawan, Kowloon, Hong Kong.
Tel: +852 2773 2888
Fax: +852 2765 8215
Mainland China
8th, Xinxiang Road, Wusha Industrial Park,
Daliang, Shunde, Foshan, Guangdong, China
Tel: +86 757 2980 8 308
Fax: +86 757 2980 8318
Macau, China
3/F, Edificio Industrial Pou Fung,
145 Rua de Francisco Xavier Pereira, Macau
Tel: +853 2875 2699
Fax: +853 2875 2661
© All rights reserved. Copying, reproducing or using the contents of this manual is not allowed without prior authorization from German Pool, violators will be prosecuted.

www.germanpool.com

Documents / Resources

| GERMAN POOL GPR-S700L Chimney Type Range Hood [pdf] User Manual
GPR-S700L, GPR-S900L, GPR-S700L Chimney Type Range Hood, GPR-S700L, Chimney Type Range Hood, Type Range Hood, Range Hood, Hood
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

GERMAN POOL User Manuals

Related Manuals