124F Series Fortinet FortiSwitch User Guide

July 15, 2024
FORTINET

124F Series Fortinet FortiSwitch

124F-Series-Fortinet-FortiSwitch-product

Product Specifications:

  • Product Series: FortiSwitch 124F Series
  • Models: FS-124F, FS-124F-POE, FS-124F-FPOE
  • Power Supply: 100-240V AC, 0.7A Max, 50/60Hz
  • PoE Max Power: Up to 185W (FS-124F-POE)

Product Usage Instructions

Installation:

Basic Connections: Connect power cable, network cables to RJ45 ports, and optional SFP transceivers for specific connections.

Rack Mount Option: Use the provided rack-mount brackets and screws to securely mount the switch in a rack.

Desktop Option: If using on a desktop, attach the rubber feet to the switch for stability.

Setup:

Front Panel – FS-124F: Locate the console port, power indicator, network ports, SFP connections, and FortiLink interface ports for setup.

Rear Panel – FS-124F: Check the power supply specifications for input voltage and current requirements.

Front Panel – FS-124F-POE: Similar to FS-124F but includes PoE ports with indicators for power delivery status.

Frequently Asked Questions

  • How do I register my Fortinet FortiSwitch?
    • To register your FortiSwitch for access to cloud management, FortiGuard updates, firmware upgrades, technical support, and warranty coverage, visit http://support.fortinet.com.
  • What are the different models in the FortiSwitch 124F Series?
    • The FortiSwitch 124F Series includes FS-124F, FS-124F-POE, and FS-124F-FPOE models with varying features such as PoE capabilities and port configurations.
  • How can I identify the ports on the FortiSwitch?
    • The switch ports are labeled on the front panel with indicators for port type (RJ45 or SFP+), connection status, speed, and activity. Refer to the user manual for detailed port identification.

Product Registration

Thank you for purchasing a Fortinet FortiSwitch. To access:
http://support.fortinet.com

  • Cloud Management
  • FortiGuard Updates
  • Firmware Upgrades
  • Technical Support
  • Warranty Coverage

Please register your Fortinet FortiSwitch:

Copyright© 2021 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®, FortiCare® and FortiGuard®, and certain other marks are registered trademarks of Fortinet, Inc., in the U.S. and other jurisdictions, and other Fortinet names herein may also be registered and/or common law trademarks of Fortinet. All other product or company names may be trademarks of their respective owners. Performance and other metrics contained herein were attained in internal lab tests under ideal conditions, and actual performance and other results may vary. Network variables, different network environments and other conditions may affect performance results. Nothing herein represents any binding commitment by Fortinet, and Fortinet disclaims all warranties, whether express or implied, except to the extent Fortinet enters a binding written contract, signed by Fortinet’s General Counsel, with a purchaser that expressly warrants that the identified product will perform according to certain expressly-identified performance metrics and, in such event, only the specific performance metrics expressly identified in such binding written contract shall be binding on Fortinet. For absolute clarity, any such warranty will be limited to performance in the same ideal conditions as in Fortinet’s internal lab tests. In no event does Fortinet make any commitment related to future deliverables, features or development, and circumstances may change such that any forward-looking statements herein are not accurate. Fortinet disclaims in full any covenants, representations, and guarantees pursuant hereto, whether express or implied. Fortinet reserves the right to change, modify, transfer, or otherwise revise this publication without notice, and the most current version of the publication shall be applicable.

For Product License Agreement / EULA and Warranty Terms, visit https://www.fortinet.com/content/dam/fortinet/assets/legal/EULA.pdf

Contents – FS-124F

124F-Series-Fortinet-FortiSwitch-fig \(1\)

Front Panel – FS-124F124F-Series-Fortinet-FortiSwitch-fig
\(2\)

Rear Panel – FS-124F124F-Series-Fortinet-FortiSwitch-fig
\(3\)

  1. Power Supply 100-240V AC, 0.7A Max, 50/60Hz

Contents – FS-124F-POE

124F-Series-Fortinet-FortiSwitch-fig
\(4\)

Front Panel – FS-124F-POE124F-Series-Fortinet-FortiSwitch-fig
\(5\)

Rear Panel – FS-124F-POE124F-Series-Fortinet-FortiSwitch-fig
\(6\)

  1. Power Supply 100-240V AC, 4.0A Max, 50/60Hz

Contents – FS-124F-FPOE

124F-Series-Fortinet-FortiSwitch-fig
\(7\)

Front Panel – FS-124F-FPOE124F-Series-Fortinet-FortiSwitch-fig
\(8\)

Rear Panel – FS-124F-FPOE124F-Series-Fortinet-FortiSwitch-fig
\(9\)

  1. Power Supply 100-240V AC, 7.0A Max, 50/60Hz

Installation Options

Your device includes a rackmount kit. You can also install your device as Desktop. Custom Rack/Rail kits are also available.

Basic Connections

124F-Series-Fortinet-FortiSwitch-fig \(10\)

Plug in your device to a power outlet using the provided power cables.

Note: We recommend connecting your FortiSwitch to an uninterruptible power supply (UPS) in case of a power outage

Rack Installation

This device mounts in a standard 19 inch rack.

  1. Attach the provided rack-mount brackets and screws
  2. Position the device and slide into the rack
  3. Fasten rack screws to secure the device

124F-Series-Fortinet-FortiSwitch-fig \(11\)

Caution: Ensure there is at least 1.5 inches of space above and below the device

Warning: For safety, it is recommended that two people install the device

Desktop Option

  1. Place the unit on a flat, clean and stable surface
  2. Ensure there is at least 1.5in of clearance for adequate airflow
  3. Plug the provided power cables into the rear of the unit and then into a grounded electrical outlet or separate power source

SFP Transceivers

To install the SFP transceivers:

  1. Slide the SFP into the cage socket until it clicks into place
  2. Lift the latch to lock the SFP

124F-Series-Fortinet-FortiSwitch-fig \(13\)

To remove the SFP transceivers:

  1. Lower the latch to unlock the SFP
  2. Carefully pull the SFP out of the cage socket

Setup Options

Set up your device locally using the GUI or CLI. Choose an option to complete your setup, then configure your device.

A GUI

An easy-to-use GUI, compatible with most web browsers. To minimize scrolling, the screen resolution should be at least 1280 x 1024 pixels

B Command Line Interface (CLI)

An alternate configuration tool from the web-based manager that uses a terminal emulation application to type commands or upload batches of commands from a text file or configuration script.

C FortiLink Management

FortiGate units can remotely manage FortiSwitch units, known as using a FortiSwitch in FortiLink mode. See the FortiOS Admin guide on docs.fortinet.com for detailed information

D FortiCloud Management

FortiSwitch Cloud manages FortiSwitch devices in standalone mode. It allows you to provision, monitor, troubleshoot, and optimize your standalone FortiSwitch deployment through an easy-to-understand user interface.

A GUI

124F-Series-Fortinet-FortiSwitch-fig \(15\)

  1. Connect port 1 to the Management Computer using the supplied Ethernet cable
  2. Enable DHCP or set the Management Computer’s IP and subnet to:
    • Static IP Address: 192.168.1.1
    • Subnet Mask: 255.255.255.0
  3. Visit https://192.168.1.99 in a web browser
  4. Log in with the username admin and no password
  5. You can now configure your FortiSwitch

Note: After you log in for the first time, you will be prompted to set a new password

B CLI124F-Series-Fortinet-FortiSwitch-fig \(16\)

  1. Connect the Console Port with a Console Cable to the USB Port on the Management Computer
  2. Start a terminal program on the Management Computer and select an available COM Port using the following default settings:
    • Baud rate: 115200
    • Data bits: 8
    • Parity: None
    • Stop bits: 1
    • Flow control: None
  3. Log in using username admin and no password
  4. You can now configure your FortiSwitch
    Note: After you log in for the first time, you will be prompted to set a new password

C FortiLink

124F-Series-Fortinet-FortiSwitch-fig \(17\)

  1. Connect a FortiSwitch FortiLink Port directly using an Ethernet Cable to a FortiGate FortiLink Port or any FortiGate Port that is not an HA port
  2. Login to the FortiGate and go to the WiFi & Switch Controller –> FortiLink Interface
  3. Add a FortiGate Port in the FortiLink interface and choose Automatically authorize devices
  4. When the FortiSwitch is online in the WiFi & Switch Controller –> Managed FortiSwitch section, you can now manage your FortiSwitch

D Cloud Management

(Connect a port to the Internet)

  1. Visit support.fortinet.com to register your device and cloud management license
  2. Sign in at https://fortilan.forticloud.com to manage your Inventory List

Resources

Refer to the following resources to continue your FortiSwitch setup.

Fortinet Customer Service & Support

Create a support account, register and manage your products, download updates, firmware images and release notes, and create technical support tickets.
https://support.fortinet.com

Fortinet Document Library

Up-to-date versions of Fortinet publications for the entire family of Fortinet products.
http://docs.fortinet.com

Training Services

Course descriptions, availability, schedules, and location of training programs in your area.
http://www.fortinet.com/support/training.html

Technical Discussion Forums

Communicate with other customers and Fortinet partners about Fortinet products, services, and configuration issues.
https://support.fortinet.com/forum

FortiGuard Threat Research and Response

Up-to-date information on vulnerabilities and threats, includes a virus scanner, IP signature look-up, and web filtering tools.
http://www.fortiguard.com

Cautions and Warnings

Environmental specifications

Ambient operating temperature: 0°C to 45°C

  • Rack Mount Instructions – The following or similar rack-mount instructions are included with the installation instructions:
  • Elevated Operating Ambient – If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the  maximum ambient temperature (Tma) specified by the manufacturer.
  • Reliable Earthing – Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).

Safety

  • Battery – Risk of explosion if the battery is replaced by an incorrect type. Do not dispose of batteries in a fire. They may explode. Dispose of used batteries according to your local regulations. IMPORTANT: Switzerland: Annex 4.10 of SR814.013 applies to batteries.

CAUTION:

There is a danger of explosion if a battery is incorrect replaced. Replace only with the same or equivalent type. Dispose batteries of according to the manufacturer’s instructions. Disposing a battery into fire, a hot oven, mechanically crushing, or cutting it can result in an explosion. Leaving a battery in an extremely hot environment can result in leakage of flammable liquid, gas, or an explosion. If a battery is subjected to extremely low air pressure, it may result in leakage of flammable liquid, gas, or an explosion.

WARNING:

Caution: This equipment is to be used in a Network Environment 0 per IECTR 62101. This product is connected only to PoE networks without routing to the outside plant.

Regulatory Notices

Federal Communication Commission (FCC) – USA

This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received; including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

WARNING: Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Industry Canada Equipment Standard for Digital Equipment (ICES) – Canada

European Conformity (CE) – EU

This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

Bureau of Standards Metrology and Inspection (BSMI) – Taiwan

The presence conditions of the restricted substance (BSMI RoHS table) are available at the link below:
https://www.fortinet.com/bsmi

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals