BIOBIDET BB-500 Toilet Seat User Manual

July 15, 2024
Biobidet

BIOBIDET BB-500 Toilet Seat

Specifications

  • Model: BB-500
  • Lid
  • Side Control Knob
  • Front Wash
  • Rear Wash
  • Dual Nozzles
  • Heated Seat
  • 4 Ft Power Cord
  • Drain/Quick Release
  • Reset Button
  • Adjustable Temps
  • T-Valve
  • Bidet Hose

Product Information

Important Safeguards Overview & Parts
Ensure to observe precautions and instructions before installation and use to avoid risks.

Getting Started
Learn about the functions and features of the bidet, including safety features.

Installation
Follow the installation guide provided for proper setup. Contact customer support for assistance or alternate fittings.

Maintenance

  • Cleaning Tips
  • Use During Power Failure
  • How To Reset
  • Removing The Unit
  • Draining The Water
  • Troubleshooting Guide

Product Usage Instructions

Functions & Features

  • Side Control Knob (2 Washes) : Adjust water pressure by rotating the control knob button.
  • Seat Sensor : Built-in sensor to prevent accidental sprays when unoccupied.
  • Front Wash & Rear Wash: Adjust water pressure by rotating the control knob button.
  • Turbo Wash : Activate Turbo spray with increased water pressure during a wash.
  • Pulse Wash : Activate Water Therapy spray for stimulating bowel movements.
  • Standard Wash : Switch back to a standard wash during a wash cycle.
  • Self-Cleaning : Rinse the nozzles for 5 seconds before each use.
  • Night Light : Adjust night light settings while the seat is unoccupied.
  • Backside Backup : Use wash functions during a power outage with ambient water temperature and pressure.
  • Side Control Buttons : Adjust water and seat temperature using the control buttons.

Safety Features
The product includes various safety features to ensure safe usage.

Installation Guide
Before installation, make sure to turn off the water shut-off valve and follow the provided steps for a successful setup. Contact customer support if needed.

IMPORTANT SAFEGUARDS

PLEASE OBSERVE THE FOLLOWING PRECAUTIONS AND INSTRUCTIONS BEFORE INSTALLATION AND USE.

  • DANGER– To reduce the risk of electrocution:
  • Do not place or store product where it can fall or be pulled into a tub or sink.
  • Do not place in or drop into water or other liquid.
  • Do not reach for a product that has fallen into water. Unplug immediately.
  • WARNING – To reduce the risk of burns, electrocution, fire, or injury to persons.
  • This product must be connected to a GFCI receptacle (wall outlet). Do not connect the power cord if it is damaged or broken. Do not plug the product into a loose electric outlet.
  • It is recommended to operate this product on a separate circuit. Sharing a circuit could cause the breaker to trip or lights to flicker.
  • Consult a qualified electrician or service person if you are not sure whether the unit is properly grounded.
  • Do not open this product for repair without authorization from the manufacturer. Only qualified service personnel should service this product. Do not use accessories not recommended by the manufacturer.
  • Connect this product to a potable cold water supply line.
  • Close supervision is necessary when this product is used by children, elderly, or adults with sensitive skin. A low temperature burn may occur when the skin has been in contact with an object at relatively low temperature for an extended period of time.
  • If using any chemical toilet bowl cleaner, be sure to wipe up any spills that splash onto the bidet. Do not use benzene or any acid chemical detergent, as they can cause discoloration. Only neutral detergents are permitted.
  • Do not plug in the power cord before connecting the water supply hose.
  • Install in an area with adequate ventilation to avoid high levels of humidity which can damage the electronic components.
  • Do not touch the power cord with wet hands or reach for a product that has fallen into water. Unplug immediately.
  • Unplug the bidet seat when cleaning or detaching from the toilet bowl. Do not plug in until plumbing work has been completed.
  • Keep the power cord away from heated surfaces to prevent a fire hazard. Keep any flammable materials away from this product at all times.
  • Never block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air openings may be blocked. Keep the air openings free of lint, hair, and the like.
  • Never use while sleeping or drowsy.
  • Never drop or insert any object into any opening or hose.
  • Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered.

SAVE THESE INSTRUCTIONS

OVERVIEW & PARTS

BIOBIDET-BB-500--Toilet-Seat-fig- \(1\)

FUNCTION & FEATURES

Side Control Knob (2 Washes)

  • Seat Sensor
    This product includes a built-in seat sensor to avoid any accidental sprays while powered. Skin contact is required to activate any wash functions while powered.BIOBIDET-BB-500--Toilet-Seat-fig- \(2\)

  • Turbo Wash
    Press the control knob button once while a wash is active to activate a Turbo spray with increased water pressure.

  • Pulse Wash
    Press the control knob button a second time while a wash is active to activate a Water Therapy spray that alternates water pressure to assist in stimulating bowel movements.

  • Standard Wash
    Press the control knob a third time while a wash is active to switch back to a standard wash.

  • Self Cleaning
    This product includes a self cleaning function that rinses the nozzles for 5 seconds before each use.

  • Night Light
    While the seat is unoccupied, long press the control knob button to switch between night light settings.

    • Mode 1 – Both lights on
    • Mode 2 – Knob light on, Bowl light off
    • Mode 3 – Both lights off
  • Backside Backup
    During a power outage, wash functions can still be used with ambient water temperature and pressure

Side Control Buttons

BIOBIDET-BB-500--Toilet-Seat-fig- \(3\)

  • Water Temp
    During a wash cycle, press the “Water Temp” button repeatedly to adjust the water temperature.

  • Seat Temp
    Press the “Seat Temp” button repeatedly to adjust the heated seat.

Safety Features

  • If the knob is not fully switched off after a wash, the unit will beep and will not allow wash functions to be activated.
  • When the water temp exceeds 109°F, it will not allow wash functions to be activated. Unplug and replug the power cord to reset the unit and resume operation.
  • Seat Temperature Protection – After 5 minutes of occupying the seat, the seat temp will automatically switch to ~84°F.

INSTALLATION GUIDE

  1. Turn Off Water
    Turn off the water shut-off valve. Drain the toilet tank completely by flushing the toilet. Unscrew the hose connected to the toilet tank. You may want to have a towel ready to catch any residual water.

  2. Remove the Toilet Seat
    Remove the mounting bolts to release the existing toilet seat from the toilet.

  3. Install Catch Plate
    Insert the rubber anchors into the toilet mounting holes. Align the installation guide to the toilet rim and place the catch plate over the mounting holes. Assemble the bolt guides by placing the metal inserts into the plastic brackets. Make sure to insert them correctly so the metal inserts sit flush on top. Place the bolt guides on the catch plate above the toilet mounting holes. Insert the bolts through the bolt guides, catch plate, and rubber anchors. Use a Phillips screwdriver to secure the catch plate on the toilet.BIOBIDET-BB-500--Toilet-Seat-fig- \(6\)

  4. Install Your BB-500
    Slide the bidet seat all the way onto the catch plate until you hear a click. Press and hold the reset button for 2 seconds before continuing installation .BIOBIDET-BB-500--Toilet-Seat-fig- \(7\)

  5. Connect the Water Hoses

  6. Install the t-valve onto the toilet tank. Ensure the cone washer is properly seated inside the t-valve.

  7. Connect your existing toilet hose to the water shut-off and t-valve.

  8. Connect the bidet hose to the bidet seat and t-valve.

  9. Open the water shut-off valve. Check for any leaking or dripping. Use a wrench to tighten any loose connections.

  10. Plug the power cord into a dedicated 120V power outlet.

Shut-off valves may vary. If supplied parts do not fit, please call 847.458.2334. Alternate fittings may be available upon request.

BIOBIDET-BB-500--Toilet-Seat-fig- \(8\)

MAINTENANCE

Cleaning the BB-500

  • When you clean this product, do not use thinner, benzene or toilet bowl cleaner, as it may cause discoloration or damage.
  • Disconnect the power cord and use a wet cloth when you clean this product.

Cleaning the Nozzle
Gently pull out the nozzle. Dip a soft cloth, sponge, or small brush into a neutral cleaning solution. Use the cloth, sponge, or brush to carefully wipe the nozzle.

Use During Power Failure
During a power outage, it is not possible to adjust the water and seat temperature. However, you can still use the bidet functions with ambient water.

Resetting the BB-500
Press and hold the reset/drain button for 2 seconds.

Cleaning the Filter Screen
This product will not operate properly if the filter screen is clogged. Please clean the screen regularly.

BIOBIDET-BB-500--Toilet-Seat-fig- \(11\)

  1. Unplug the power cord.
  2. Close the water shut-off valve.
  3. Unscrew the bidet hose from the bidet seat.
  4. Clean the filter screen with a small brush.
  5. Re-connect the bidet hose.
  6. Open the water shut-off valve.
  7. Plug in the power cord.

Removing the BB-500

BIOBIDET-BB-500--Toilet-Seat-fig- \(12\)

  1. Disconnect the power plug.
  2. Close the water supply shut-off valve.
  3. Hold the side drain button and slide the bidet seat off the catch plate.

Draining the Water
Before draining, unplug the power cord and wait 30 minutes until the unit has cooled down. Do not insert your finger into the drain hole. If you do not intend to use this product for an extended period of time, drain the water from the bidet seat

  1. Disconnect the power plug.
  2. Close the water shut-off valve.
  3. Press the drain button until the water is completely drained.

Open the water shut-off valve to resume usage.

TROUBLESHOOTING GUIDE

Problem Cause Solution

Water does not spray

|

Bidet hose has blockage.

| Inspect and reattach bidet hose

The shut-off valve is closed.

|

Open the shut-off valve

Water is leaking (while not occupied)| Knob is not completely turned to “Stop”|

Close the knob completely.

Nozzle is not extending

| The nozzle is in a self-clean cycle.| Wait a few seconds

Not in contact with seat sensor

|

Occupy the seat before using

Water temp malfunction| Unplug and replug the power cord.

Nozzle is not extending & toilet bowl is filling up

|

Bidet hose blockage

|

Clean the filter screen and reconnect the bidet nuts.

Low water pressure

|

Filter screen is blocked.

|

Clean filter screen.

No warm water

|

Product is not connected to a power supply.

|

Plug in the power cord

Product needs to be reset.

| Reset unit by holding and pressing the reset button.
Heated seat is not working|

Function is turned off.

|

Turn on and adjust the temp.

Seat temp drops during wash function

|

Low-temp burn prevention is turned on

|

After a wash cycle, the seat temp will slowly rise.

Night light does not turn on|

Night/Knob light malfunction

|

Unplug and replug power cord.

Knob light does not turn on

Knob is not working

|

Not in contact with seat sensor

|

Occupy the seat before using

Specifications

| Specifications| BB- 500
---|---|---

Power Rating

|

120Vac, 60Hz, 1050W

Water Inlet Pressure

|

0.1~ 0.74MPa (0.4 ~ 7.5 kgf/cm)

Power Cord

|

4 feet

Wash Device

|

Water Amount Regulation

|

Stepless regulation

Water Temperature Regulation

|

~95/100°F /OFF

Heating Method

|

Instant heating

Protective Device

| Anti-siphon valve

+ anti-backflow valve

Safety Device

|

Double thermostat

Heated Seat

|

Surface Temperature

|

~91.4/98.6 /OFF

Heater Power

|

50 W

Safety Device

|

Thermostat & fuse

Others

|

Heating Wire Power

|

180W

Safety Device

|

Thermostat & fuse

Antibacterial Material

|

Nozzle and seat

Seat Temperature Protection

|

Yes

DIMENSION

BIOBIDET-BB-500--Toilet-Seat-fig- \(13\)

WARRANTY

WARRANTY SUMMARY

  • 1-Year Full Warranty
  • At-Home Repair Instructions (Limited to certain products)
  • Service Center Repair Option*
  • *Warranty does not cover inbound shipping. C
  • customer Support is Available via Phone, Chat, & Email.

1-YEAR FULL WARRANTY
Bio Bidet Innovation LLC warrants its product to be free from manufacturing defects under normal use and service for a period of one (1) year from the original date of purchase.

This warranty is extended only to the ORIGINAL PURCHASER.

  • Bio Bidet Innovation LLC’s obligations under this warranty are limited to repair or replacement, at Bio Bidet Innovation LLC’s option, of products or parts found to be defective, provided that such products were properly installed and used in accordance with instructions.
  • Bio Bidet Innovation LLC reserves the right to make such inspections as may be necessary in order to determine the cause of the defect.
  • Bio Bidet Innovation LLC will not charge for labor or parts in connection with authorized warranty repairs.
  • Bio Bidet Innovation LLC is not responsible for the cost of removal, return, initial install, and/or re-installation of products.
  • Bio Bidet Innovation LLC shall not be responsible or liable for any failure of, or damage to, this plumbing product or product component caused by either chloramine in the treatment of public water supply or in-tank bowl cleaners containing chlorine (calcium hypochlorite).

This warranty does not apply to the following items:

  • Damage or loss sustained in a natural calamity such as fire, earthquake, flood, thunder electrical storm, etc.
  • Damage or loss resulting from any unreasonable use, misuse, abuse, negligence, or improper maintenance of the product.
  • Damage or loss resulting from removal, improper repair, or modification of the product.
  • Damage or loss resulting from sediments or foreign matter contained in a water system.
  • Damage or loss resulting from improper installation or from installation of a unit in a harsh and/or hazardous environment.

This warranty gives you specific legal rights. You may have other rights which vary from state to state. To obtain warranty repair service under this warranty, you must contact Bio Bidet Innovation LLC or an authorized distributor. This written warranty is the only warranty made by Bio Bidet Innovation LLC.  Repair or replacement as provided under this warranty shall be the exclusive remedy available to the purchaser. Bio Bidet Innovation LLC shall not be responsible for loss of the product or for other incidental, special, or consequential damages or expenses incurred by the purchaser, or for labor or other costs due to installation or removal, or costs of repairs by others, or for any other expense not specifically stated above. Except to the extent prohibited by applicable law, any implied warranties, including that of merchantability or fitness for use, are expressly limited to the duration of this warranty. Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above limitation and exclusion may not apply to you.

BIO BIDET INNOVATION LLC

FAQ

Q: What should I do if the bidet is not functioning properly?
A: Refer to the troubleshooting guide in the manual or contact customer support for assistance.

Q: Can I adjust the water and seat temperature?
A: Yes, you can adjust the water and seat temperature using the side control buttons.

Q: How do I activate the self-cleaning function?
A: The self-cleaning function activates automatically for 5 seconds before each use.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals