SHURE PSM1000 Wireless Personal Monitor System User Guide
- June 7, 2024
- Shure
Table of Contents
- SHURE PSM1000 Wireless Personal Monitor System User Guide
- IMPORTANT SAFETY INSTRUCTIONS
- SAFETY PRECAUTIONS
- Important Product Information
- Information to the user
- PSM 1000
- Components
- Quick start Instructions
- Front Panel Controls
- Rear Panel
- Bodypack Receiver
- Battery Life
- Multiple System Setup
- CueMode
- Adding Transmitters to the CueMode List
- Auditioning Mixes
- Frequency Scan
- Sync
- Downloading settings from the bodypack
- Sending settings to the bodypack
- Creating Custom Groups
- MixMode
- LOOP Applications
- MixMode for Multiple Systems
- Floor Monitors
- Recording Devices
- Squelch
- Squelch Settings
- Point-to-Point Wireless Audio
- Ethernet Connection
- Accessing the Network with a Computer
- Static IP Addressing
- Connecting Transmitters
- Spectrum Scan
- Scanning and Deploying Frequencies
- Viewing Spectrum Data
- Updating Receiver Firmware
- Specifications
- PSM 1000
- P10T
- Power Requirement
- Audio Input
- Maximum Input Level
- Pin Assignments
- Audio Output
- P10R+
- 4-band Parametric EQ
- Furnished Accessories
- Optional Accessories
- Frequency Range and Transmitter Output Power
- Australia Warning for Wireless
- Switzerland Warning for Wireless
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SHURE PSM1000 Wireless Personal Monitor System User Guide
IMPORTANT SAFETY INSTRUCTIONS
-
READ these instructions.
-
KEEP these instructions.
-
HEED all warnings.
-
FOLLOW all instructions.
-
DO NOT use this apparatus near water.
-
CLEAN ONLY with dry cloth.
-
DO NOT block any ventilation openings. Allow sufficient distances for adequate ventilation and install in accordance with the manufacturer’s instructions.
-
DO NOT install near any heat sources such as open flames, radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not place any open flame sources on the product.
-
DO NOT defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
-
PROTECT the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
-
ONLY USE attachments/accessories specified by the manufacturer.
-
USE only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
-
UNPLUG this apparatus during lightning storms or when unused for long periods of time.
-
REFER all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
-
DO NOT expose the apparatus to dripping and splashing. DO NOT put objects filled with liquids, such as vases, on the apparatus.
-
The MAINS plug or an appliance coupler shall remain readily operable. The airborne noise of the Apparatus does not exceed 70dB (A).
-
Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective earthing connection.
-
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
-
Do not attempt to modify this product. Doing so could result in personal injury and/or product failure.
-
Operate this product within its specified operating temperature range.
SAFETY PRECAUTIONS
The possible results of incorrect use are marked by one of the two
symbols—”WARNING” and “CAUTION”—depending on the imminence of the danger and
the severity of the damage.
WARNING: Ignoring these warnings may cause severe injury or death as a
result of incorrect operation.
CAUTION: Ignoring these cautions may cause moderate injury or property
damage as a result of incorrect operation.
CAUTION
- Never disassemble or modify the device, as failures may result.
- Do not subject to extreme force and do not pull on the cable or failures may result.
- Keep the product dry and avoid exposure to extreme temperatures and humidity.
WARNING
- If water or other foreign objects enter the inside of the device, fire or electric shock may result.
- Do not attempt to modify this product. Doing so could result in personal injury and/or product failure.
WARNING: Battery packs shall not be exposed to excessive heat such as sunshine, fire, or the like. This device is able to produce sound volume higher than 85 dB SPL. Please check your maximum allowed continuous noise exposure level based on your national employment protection requirements
WARNING
LISTENING TO AUDIO AT EXCESSIVE VOLUMES CAN CAUSE PERMANENT HEARING DAMAGE. USE AS LOW A VOLUME AS POSSIBLE.
Over exposure to excessive sound levels can damage your ears resulting in permanent noise-induced hearing loss (NIHL). Please use the following guidelines established by the Occupational Safety Health Administration (OSHA) on maximum time exposure to sound pressure levels before hearing damage occurs.
90 dB SPL
at 8 hours| 95 dB SPL
at 4 hours| 100 dB SPL
at 2 hours| 105 dB SPL
at 1 hour
---|---|---|---
110 dB SPL
at ½ hour| 115 dB SPL
at 15 minutes| 120 dB SPL
Avoid or damage may occur
This product is intended for professional use only. This product should only be sold through professional sales channels.
HEARING PRECAUTIONS
To prevent possible hearing damage, do not listen at high volume levels for long periods.
Important Product Information
LICENSING INFORMATION
Licensing: A ministerial license to operate this equipment may be required in certain areas. Consult your national authority for possible requirements. Changes or modifications not expressly approved by Shure Incorporated could void your authority to operate the equipment. Licensing of Shure wireless microphone equipment is the user’s responsibility, and licensability de pends on the user’s classification and application, and on the selected frequency. Shure strongly urges the user to contact the appropriate telecommunications authority concerning proper licensing, and before choosing and ordering frequencies.
Information to the user
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful
- This device must accept any interference received, including interference that may cause undesired
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa tion. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving
- Increase the separation between the equipment and the
- Connect the equipment to an outlet on a circuit different from that to which the receiver is
- Consult the dealer or an experienced radio/TV technician for
This device contains license exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Develop ment Canada’s licenceexempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause
- This device must accept any interference, including interference that may cause undesired operation of the device.
Industry Canada ICES-003 Compliance Label: CAN ICES-3 (B)/NMB-3(B)
Note: EMC conformance testing is based on the use of supplied and
recommended cable types. The use of other cable types may degrade EMC
performance. Changes or modifications not expressly approved by the
manufacturer could void the user’s authority to operate the equipment.
PSM 1000
The PSM 1000 Personal Monitor System from Shure brings personal monitoring to its most advanced level yet. The full-rack, dual-channel, networkable transmitter is ideally suited for the demands of professional touring and installation applications, and the diversity bodypack receivers deliver pristine RF signal and audio quality. Networkability over Ethernet connection enables remote control of transmitter functions and comprehensive frequency coordination via Wireless Workbench software.
Components
- P10T Rackmount Transmitter
- P10R+ Bodypack Receiver (2)
- Two 1/2 Wave Antennas
- AA Batteries (4)
- Antenna Cables (2)
- IEC Power Cable and IEC Extension Cable
- Ethernet Network Cable
- Zippered Bag
Rackmount supplies:
- 2 antenna hole plugs
- 4 rack mounting screws with washers
Quick start Instructions
Rack Mount Transmitter
- Connect to a power outlet using the supplied power cable.
- Attach the supplied antennas to the antenna out BNC connectors.
- Connect the audio source, such as the output of a mixer, to the audio inputs. You can use both input jacks or choose either one for a mono source.
- Switch RF off and power on.
- For mono (one input), access the Audio menu and select Mono.
- Adjust the audio source level so that, for the average input signal level, the top two yellow LEDs flicker and the lower LEDs are solid. If the red clip LED illuminates and a warning appears on the LCD, the inputs are overdriven. Decrease the audio input level to +4 dBu from the Audio menu. If the signal level is too low, change the input sensitivity to –10 dBV
Bodypack
Open by pressing the latches on both sides and pulling. Insert the batteries or battery pack and attach antennas. Turn on using the volume knob. The battery light illuminates.
Scan and Sync
- On the bodypack, press the scan button. The display flashes SYNC NOW….
- Align the IR windows on the bodypack and rack unit, the IR window on the transmitter illuminates. Press the sync button on the transmitter. The rack unit Level LEDs flash, and the screen displays SYNC SUCCESS.
- Turn the RF switch on. The blue RF LED illuminates on the bodypack to indicate that it is detecting the transmitter. The bodypack also displays the RF signal strength (RF).
- Important: Turn bodypack volume down before plugging in earphones.
- Insert the earphones and slowly turn up the volume
Front Panel Controls
-
Sync Window
Align bodypack IR window with sync window on TX. -
RF Switch
Mutes RF output. For setting up multiple systems or adjusting settings without transmitting unwanted RF or audio signals. -
Audio Indicators
Use the control wheel to adjust the audio so that, for the average input signal level, the top two yellow LEDs flicker and the lower LEDs are solid. Press the enter button to save the value, exit to cancel. The red clip LED indicates the inputs are overdriven. Reduce the level at the audio source or change the input sensitivity of the rack unit from the Audio > Input menu. -
Status Display and ControlsUse the navigation buttons to access the configuration menu. Push the control wheel to move the cursor to the next item.
Turn the control wheel to change a parameter—the enter button flashes. Press it to save the value. Press the exit button to cancel changes and return to the previous menu. -
Headphone Monitoring
The monitor control adjusts signal output to the 3.5 mm headphone jack. Push button to toggle between transmitters. Monitor clip LED indicates headphone audio is clipping. -
Power Switch
Turns the unit on and off.
Rear Panel
-
Primary power switch
This switch disconnects power to the unit. It is not affected by the interface power lock in the Util menu. Only the front power switch can be locked. -
Power plug
AC mains power input, IEC Connector 100-240 Vac. -
AC mains power passthrough
Use with an IEC extension cable to supply AC power to another device. Unswitched. -
Antenna (BNC) port
Attach supplied antennas. If you are rack mounting, use a front panel or remote mounting kit from Shure. -
loop out
Sends audio signal going into the transmitter to another device. -
Audio Inputs
Connect to balanced or unbalanced outputs. Use either jack for mono input. Accepts male XLR or 6.35 mm (1/4-inch) TRS plugs. -
Ethernet Jack
Two-port RJ-45 Ethernet jack for connection to a network or computer
Bodypack Receiver
① Power Switch and Volume Control
Turns the bodypack on and off and adjusts earphone volume.
② 3.5 mm Earphone Jack
Insert earphones here.
③ Scan Button
Press the scan button to find an available frequency. Press and hold for two
seconds to find the group with the most available
channels.
④ IR Window
For transmitting settings between bodypack and rack unit.
⑤ Battery Compartment
Requires 2 AA batteries or Shure rechargeable battery. Open by pressing the
latches on both sides and pulling.
⑥ Menu buttons
Use in conjunction with the ▼▲ buttons to access the configuration menus.
⑦ ▼▲ Buttons
Use to adjust the audio mix (in MixMode only), or in conjunction with the menu
buttons to change settings.
⑧ LCD Screen
Displays current settings and menus.
⑨ Tri-Color Battery LED
Illuminates green, amber, or red to indicate battery power. When red, change
battery immediately.
⑩ Blue RF LED
Indicates the bodypack is receiving a signal from the transmitter.
⑪ SMA Connector
For detachable antennas.
⑫ Removable AA Adapter
Remove to use with a Shure SB900B rechargeable battery.
Note: To remove adapter, open door and slide out. To reinstall adapter, place over the clip and press, there will be an audible click when seated.
RF Settings
Access the following RF settings from the RADIO menu.
G
Group number. Each group contains channels selected to work well together in a
single installation.
CH
Channel number. Sets the receiver to a channel in the selected group.
888.888 MHz
Displays the frequency to which the transmitter is set. Highlight and use the
▼▲ buttons to set the transmitter to a specific
frequency.
SQUELCH
Adjusts the squelch setting.
FULL SCAN
Performs spectrum scan and displays open frequencies in a graphical interface.
RF PAD
Attenuates antenna signals in 3 dB increments.
ANTENNA
Selection for single antenna operation. Disables diversity reception.
Audio Settings
Access the following audio settings from the Audio menu.
Output Mode (MODE)
STEREO
Receive left and right inputs as a stereo signal
MIXMODE®
Set your receiver to combine the left and right channel for simultaneous
listening in both ears or pan to listen to only the left or right channel
Four-Band Parametric Equalizer (EQ) The parametric equalizer is divided into
four frequency bands: LOW, LOW MID, HIGH MID, and HIGH. When the EQ is
enabled, the following parameters are adjustable:
FREQUENCY
Select the center frequency of the band to boost/cut
Q
Adjusts the width and slope of the frequency band (measured in octaves)
GAIN
Adjustable in 2 dB increments from -6 dB (cut) to +6 dB (boost)
NOTE: HIGH and LOW are shelf filters, and therefore do not have adjustable Q widths. The HIGH shelf is fixed at 10 kHz; the LOW shelf is fixed at 100 Hz.
Volume Limiter (V LIM)
V LIM
Set a value (OFF to 48
dB, adjustable in 3 dB increments) to attenuate the highest possible volume
level. Turning the volume knob through its entire range of motion still
affects volume; the limit simply narrows the range of dB adjustment.
Note: The volume limit does not compress the audio signal.
Volume Lock (V LOCK)
P9RA+ and P10R+ only
ON
The volume is locked to the physical position of the volume knob
Input EQ Preset (EQPre)
Input EQ affects the signal after it is sent to the receiver, but before the
headphone output, modifying the overall sound of the
entire system.
Match (default)
Matches the frequency response of legacy PSM receivers, allowing for matched
audio with mixed-inventory setups
Flat
Offers a flat frequency response curve
Off
Audio bypasses input EQ
Balance (BAL ST / BAL MIX)
▼▲ Buttons
Left and right balance for earphones when in stereo mode, or mix of left and
right channel for MixMode
Utilities and Display Settings
Access the following settings from the UTILITIES menu.
CUEMODE
Enters CUEMODE to exit, press enter and select EXIT CUEMODE
DISPLAY
Change the display settings on the bodypack
CONTRAST
Sets display brightness to high, low, or medium.
LOCK PANEL
Locks all controls except power and volume.To unlock, press exit, select OFF,
and press enter.
BATTERY
When using a Shure rechargeable battery, the following information is
displayed: Hrs: Min Left, temperature, Status, Cycle
Count, and Health.
AUTO OFF
Sets the time at which the receiver is powered off after entering power-save
mode (when POWER SAVE is displayed on
the screen).
RESTORE
Returns receiver to factory default settings.
Battery Life
Power-save mode: When there are no earphones plugged in for 5 minutes,
the receiver enters power-save mode to preserve battery life. The LED slowly
fades on/off in this mode and continues to display the color that represents
the remaining battery life.
Note: Battery life using Energizer brand AA Alkaline batteries and the
following conditions:
- Receiver audio set to V LIMIT = 0dB
- Transmitter audio INPUT set to Line+4 dBu and Level set to −9 dB
- Audio input to the transmitter: pink noise at +8.7 dBV
- Audio output at receiver: 115 dB SPL in ear with SE425 earphones (impedance at 22 Ώ) set at volume level
Note: Using lower-impedance earphones or ones with different sensitivity,
different battery types, and higher gain settings in the PSM system may cause
the receiver battery life to be different than specified.
Pink noise is a signal with a frequency spectrum such that the power spectral
density is inversely proportional to the frequency. In pink noise, each octave
carries an equal amount of noise power.
Note: A Battery Hot warning indicates that transmitter battery needs to
cool off. Otherwise, the transmitter will shut down. Let the device cool down
and then consider swapping the transmitter battery to continue operation.
Identify any possible external heat sources to the transmitter and operate the
transmitter away from those external heat sources.
All batteries should be stored and operated away from external heat sources in
reasonable temperature conditions for best performance.
Multiple System Setup
When setting up multiple systems, designate a single bodypack to scan for
available frequencies and download them to all the rack units.
The bodypack must be from the same frequency band as all the transmitters.
-
Power on all the rack Turn off the RF. (This prevents them from interfering with the frequency scan.)
Note: Turn on all other wireless or digital devices as they would be during the performance or presentation (so the scan will detect and avoid any in
terferance they generate). -
Use the bodypack to scan for a group by pressing and holding the scan button for two seconds. The bodypack dis
plays the group and the number of available channels, and flashes SYNC NOW….
Important: Note the number of available channels. If you have more rack units than available channels, eliminate potential sources of interference and try again, or call Shure Applications for assistance. -
Sync the bodypack with the first rack unit by aligning the IR windows and pressing
-
Press scan again on the bodypack to find the next available
-
Sync the bodypack with the next rack
-
Repeat with all the rack
-
Sync each performer’s bodypack to its respective rack unit by aligning the IR windows and pressing snyc. DO NOT press scan on the
Turn on the RF on all rack units. The systems are ready to use
All batteries should be stored and operated away from external heat sources in
reasonable temperature conditions for best performance.
CueMode
CueMode allows you to upload the name and frequency settings from multiple
rack units and store them as a list on a single bodypack. You can then, at any
time, scroll through that list to hear the audio mix from each transmitter,
just as each performer does during a show.
CueMode lists are retained even if CueMode is exited, the bodypack is turned
off, or batteries are removed.
Note: Set the channel frequency and assign display names for each
transmitter before creating your CueMode list.
Adding Transmitters to the CueMode List
Note: The transmitter must be from the same frequency band as the bodypack.
-
Open the battery door and press the enter
-
From the main menu, scroll to UTILITIES and press Select CueMode and press enter again.
-
Align IR windows and press sync on the rack
The LCD displays SYNC SUCCESS after frequency and name data are uploaded to the CueMode list. It also displays the CueMode number for that transmitter and the total number of transmitters. -
Repeat the above step for each
Note: Syncing while in CueMode does not change any of the settings on the bodypack.
Auditioning Mixes
- Enter CueMode from the UTILITIES
- Use the ▼▲ buttons to scroll through your CueMode list to hear the
Exiting CueMode
Exit CueMode by pressing enter and selecting EXIT CUEMODE.
Managing CueMode Mixes
While in Cue Mode, you can access the following menu by pressing enter:
REPLACE MIX
Select and press sync on a rack unit to upload new data for the current mix (for example, if you have changed the trans mitter frequency).
DELETE MIX
**** Removes the selected mix.
DELETE ALL
Removes all mixes.
EXIT CUEMODE
**** Exits CueMode and returns the bodypack to the previous frequency setting.
Frequency Scan
Use a frequency scan to analyze the RF environment for interference and identify available frequencies. There are three types of scan:
-
Channel Scan Press the scan button on the Finds the first available channel.
-
Group Scan Press and hold the scan button for two Finds the group with the greatest number of available chan nels. (Each group contains a set of frequencies that are compatible when operating multiple systems in the same environ ment.)
-
Full Scan From the bodypack menu select RADIO > FULL SCAN. Press RUN SCAN to initiate a full Press SPEC
TRUM to view full results in a graphical display.
Note: When performing a frequency scan: -
Turn off the RF on the transmitters for the systems you are setting (This prevents them from interfering with the fre quency scan.)
-
Turn on potential sources of interference such as other wireless systems or devices, computers, CD players, large LED panels, effects processors, and digital rack equipment so they are operating as they would be during the presentation or performance (so the scan will detect and avoid any interference they generate).
Sync
You can transfer frequency settings in either direction: from the bodypack to
the rack unit, or from the rack unit to the body pack.
Note: You can also choose to transfer other settings to the bodypack
during a sync, such as lock or mode settings, using the Sync > RxSetup menu on
the rack transmitter
Downloading settings from the bodypack
- Press the scanbutton on the
- Align the IR windows and press the syncbutton from the rack transmitter LCD menu while the bodypack display is flashing “SYNC NOW…”.
The level LEDs on the rack unit flash.
Sending settings to the bodypack
-
Press the Sync button on the rack transmitter to access the sync
-
Align the IR
When properly aligned the IR window on the transmitter illuminates. -
Press Sync to transfer settings.
The blue LED on the bodypack flashes.
Creating Custom Groups
This feature allows you to create your own groups of frequencies. Menu: Radio
Custom
-
Turn the Control wheel to select a custom group from the Group (U1, U2, etc.)
-
Push the Control wheel to move to the Channel parameter and turn it to select a channel (01, 02, 03, )
-
Push the Control wheel to move to the Freq parameter and select a frequency for that
-
Push the Next menu key to select a frequency for the next channel in that
-
Select Load to find all other devices of the same model and band on the Then press enter to deploy the custom group list to all these devices.
This overwrites all existing custom groups. -
Clear deletes all custom groups for all devices on the
MixMode
Some performers need to hear more of their own voice or instrument, while
others want to hear more of the band. With Mix Mode, the performer creates
their own mix using the balance control (▼▲ buttons) on the bodypack.
To use MixMode, send a solo mix of the performer to the L/CH1 input on the
transmitter, and send a band mix to the R/CH2 in put.
Set the performer’s bodypack for MixMode. The bodypack combines the two
signals and sends them to both earphones, while the balance control on the
bodypack adjusts the relative levels for each. For IFB applications, send two
independent program feeds into the L/CH1 and R/CH2 input of the transmitter.
With MixMode, the director or broadcast talent can listen to either feed using
the balance control (▼▲ buttons) on the bodypack to pan to ei ther audio
signal.
LOOP Applications
Use LOOP OUT L (left) and R (right) outputs to send a copy of the audio signal
going into the transmitter to other devices. Fol
lowing are a few of the many applications for these outputs.
Note: The input level control and the input pad do not affect the LOOP
OUT signals.
MixMode for Multiple Systems
Configure each system for MixMode. From the mixing console, send a mix of the
whole band to input 2 of the first transmitter. Connect the LOOP OUT R output
to the R/CH2 input of the next transmitter. Continue the chain with all the
transmitters.
Next, create solo mixes for each performer. Send each mix to input 1 of the
transmitter for that performer.
Floor Monitors
Send the audio from the LOOP outputs to onstage loudspeakers. The bodypack and
the onstage monitors receive the same audio signals.
Note: The LOOP audio outputs will not drive passive loudpeakers, and must be
sent to a power amplifier or an active loudspeaker.
Recording Devices
To record a performance, connect the LOOP outputs to the inputs of a recording device.
Squelch
Squelch mutes audio output from the bodypack when the RF signal become noisy.
While squelch is activated, the blue LED on the bodypack turns off.
For most installations, squelch does not need adjustment, and it keeps the
performer from hearing hiss or noise bursts if the RF signal becomes
compromised. However, in congested RF environments or in close proximity to
sources of RF interference (such as large LED video panels), the squelch may
need to be lowered to prevent excessive audio dropouts. With lower squelch
settings, the performer may hear more noise or hiss, but will experience fewer
audio dropouts.
Important: Before lowering squelch, first try to eliminate the problem by
finding the best set of frequencies for your installation and removing
potential sources of interference.
Caution: Turning off or lowering the squelch setting can increase the noise level and cause discomfort to the performer:
- Do not lower the squelch setting unless absolutely
- Turn earphone volume to the lowest setting before adjusting
- Do not change the squelch setting during a
- Turn up the transmitter level setting to make noise or hiss less
Squelch Settings
HIGH (NORMAL) | Default factory setting. | |
---|---|---|
MID | Moderately decreases the signal-to-noise ratio required to |
squelch the receiver.
LOW| | Greatly decreases the noise squelch threshold.
PILOT **ONLY*| **| Turns off noise squelch leaving only pilot
squelch on.
NO **SQUELCH***
| *| Turns off noise and pilot tone squelch. (Sometimes used as a
debugging tool by monitor engineers or RF coordinators to “listen” to the RF
environment.)
Symbol appears in dis-**
play window.
| |
Point-to-Point Wireless Audio
Use PTP mode to allow a P10T to transmit to a UHF-R receiver. This allows a
transmitter and receiver setup where both units are racked and powered by AC.
For more information visit: www.shure.com/americas/products/personal-monitor-
systems
Ethernet Connection
Each transmitter has an RJ-45 port on the back for connecting to other
transmitters over an Ethernet network. Networking transmitters allows you to
automatically set frequencies for all the transmitters with a single group
scan command.
Add transmitters to a network using the default automatic network setting
(Util > Network > Mode > Automatic):
- Connect transmitters to an Ethernet router with DHCP
- Use Ethernet switches to extend the network for larger
- Connect transmitters in
Accessing the Network with a Computer
You can control and monitor all networked transmitters through a computer
running Shure Wireless Workbench software, Ver
sion 6 or later. If using the default automatic network setting, make sure
your computer is configured for DHCP.
Note: Some security software or firewall settings on your computer can
prevent you from connecting to the transmitter. If using firewall software,
allow connections on port 2201.
Static IP Addressing
Static IP addressing is also supported. An IP address can be assigned through
the network menu (Util > Network > Mode > Manual).
Note: Dual transmitters use a single IP address, which may be set through
either LCD interface’
Connecting Transmitters
Spectrum Scan
Use this feature to scan the full RF spectrum for potential sources of interference and deploy open frequencies to all receivers on the network. A graphical representation of the scan data may be viewed on both the transmitter and receiver. This allows you to scroll through the graph to reveal details about the frequency and strength of the interfering signals.
Scanning and Deploying Frequencies
-
Turn off RF on all
-
Collect the scan data. From the bodypack receiver MAIN MENU, select RADIO > FULL SCAN > RUN SCAN
The receiver displays SPECTRUM SCAN and scans the full spectrum. -
Load the scan data from the bodypack receiver to the rack Align the IR windows and press Sync > Spectrum > SyncScan
The receiver displays the scan data as a graph and gives options for viewing and deploying. -
Search network for devices. From the rack transmitter Sync > Spectrum menu, press
The rack transmitter searches the network for all available transmitters. -
Choose a Use the control wheel to select from the available groups.
The number of open frequencies for each group is displayed next to Open Frequencies. -
Deploy Press the flashing enter button to deploy frequencies to all channels.
The LEDs flash on all affected channels.
Viewing Spectrum Data
From the Bodypack Receiver
MAIN MENU > RADIO > FULL SCAN > SPECTRUM
- Adjust the cursor position using the ▼▲
- Press enter to zoom in at the cursor Press exit to zoom out.
- Press scan to display frequency and power of signal at the cursor
From the Rack Transmitter
Sync > Spectrum
- Adjust the cursor position by pressing Cursor and using the control
- Frequency and power of signal at the cursor position is displayed at the top of the
- Press Zoom and use the control wheel to zoom in and out.
Updating Receiver Firmware
Use the following steps to update the firmware on a bodypack receiver.
- Use the WWB update manager to download the receiver firmware to the rack
- On the transmitter, navigate to the Util > More > FW Update
- Align the receiver and transmitter IR ports and press The download begins, which can take 50 seconds or longer.
Once the download is complete, the receiver automatically begins the firmware update, which overwrites the existing firmware.
CAUTION! Do not turn off the receiver until the update is complete.
Specifications
PSM 1000
RF Carrier Range
470–952 MHz
Compatible Frequencies
Per band 39
Tuning Bandwidth
72–80 MHz
Operating Range
environment dependent
90 m ( 300 ft)
Audio Frequency Response
35 Hz–15 kHz (±1 dB)
Signal-To-Noise Ratio
A-Weighted
90 dB (typical)
Total Harmonic Distortion
ref. ±34 kHz deviation @1 kHz
<0.5% (typical)
Companding
Patented Shure Audio Reference Companding
Spurious Rejection
ref. 12dB SINAD
80 dB (typical)
Frequency Stability
±2.5 ppm
MPX Pilot Tone
19 kHz (±0.3 kHz)
Modulation
FM*, MPX Stereo
Operating Temperature
-18°C to +57°C
P10T
RF Output Power
selectable: 10, 50, 100 mW (+20 dBm)
RF Output Impedance
50 Ω (typical)
Net Weight
4.7 kg (10.4) lbs
Dimensions
44 x 483 x 343 mm (1.7 x 19.0 x 13.5 in.), H x W x D
Power Requirement
Input| 100–240 V AC, 50/60 Hz, 0.5 A max.
(5.5, with outlet loaded)
---|---
Output| 100–240 V AC, 50/60 Hz, 5 A max.,
unswitched
Audio Input
Connector Type
Combination XLR and 6.35 mm (1/4″) TRS
Polarity
XLR
| Noninverting (pin 2 positive with re
spect to pin 3)
---|---
6.35 mm (1/4″) TRS| Tip positive with respect to ring
Configuration
Electronically balanced
Impedance
70.2 kΩ (actual)
Nominal Input Level
switchable: +4 dBu, –10 dBV
Maximum Input Level
+4 dBu | +29.2 dBu |
---|---|
-10 dBV | +12.2 dBu |
Pin Assignments
XLR | 1=ground, 2=hot, 3=cold |
---|---|
6.35 mm (1/4″) TRS | Tip=hot, Ring=cold, Sleeve=ground |
Phantom Power Protection
Up to 60 V DC
Audio Output
Connector Type
6.35 mm (1/4″) TRS
Configuration
Electronically balanced
Impedance
Connected directly to inputs
P10R+
Tri-Band RF Filtering
–3 dB at 30.5 MHz from the center frequency of each band
Active RF Gain Control
31 dB
Active RF Sensitivity
at 20 dB SINAD 2.2 µV
Image Rejection
90 dB
Adjacent Channel Rejection
70 dB
Latency
0.37ms
Squelch Threshold
22 dB
SINAD (±3 dB)
Intermodulation Attenuation
70 dB
Blocking
80 dB
Audio Output Power
1 kHz at Less than 1%distortion, Maximum Headphone Output Power, at 16 Ω
100 mW (per output)
Minimum Load Impedance
4 Ω
Output Impedance
4-band Parametric EQ
Low Shelf | SelectableGain: ±2 dB, ±4 dB, ±6 dB @ 100 Hz |
---|
Low Mid
| SelectableGain: ±2 dB, ±4 dB, ±6 dB at 160 Hz, 250 Hz,
400 Hz, 500 Hz, 630 HzSelectableQ: 0.7, 1.4, 2.9, 5.0, 11.5
High Mid
| SelectableGain: ±2 dB, ±4 dB, ±6 dB at 1 kHz, 1.6 kHz,
2.5 kHz, 4 kHz, 6.3 kHzSelectableQ: 0.7, 1.4, 2.9, 5.0, 11.5
High Shelf| SelectableGain: ±2 dB, ±4 dB, ±6 dB @ 10 kHz
Volume Limiter
Selectable: OFF (0 dB) to -48 dBin 3 dB steps
Volume Lock
Selectable: 0 dB to -70 dB
Net Weight
158 g (Without Battery)
Dimensions
99 x 66 x 23 mm (3.9 in. x 2.6 in. x 0.9 in.) H x W x D
Battery Life
4–6 hours (continuous use) AA batteries
Furnished Accessories
Omnidirectional Whip Antenna, Yellow Tip (470-542 MHz) | UA700 |
---|---|
Omnidirectional Whip Antenna, Gray Tip (540-626 MHz) | UA710 |
Omnidirectional Whip Antenna, Black Tip (596-692 MHz) | UA720 |
Omnidirectional Whip Antenna, Blue Tip (670-830 MHz) | UA730 |
Omnidirectional Whip Antenna, Red Tip (830-952 MHz) | UA740 |
1/2 Wave Omnidirectional Receiver Antenna for improved wireless signal
reception| UA8
Antenna extension cables (2)| 95B9023
Carrying/Storage Bag| 95A2313
Hardware Kit (Rack mounting Screws)| 90XN1371
Bumper Kit| 90B8977
AA battery adapter| 65A15224
Optional Accessories
Passive Directional Antenna 470-952 MHz. Includes 10 foot BNC to BNC
cable.| PA805SWB
---|---
PWS Helical Antenna, 480-900 MHz| HA-8089
PWS Domed Helical Antenna, 480-900 MHz| HA-8091
Wideband Omnidirectional Antenna (470-1100 MHz)| UA860SWB
2 ft. BNC-BNC Coaxial Cable| UA802
6 foot (1.8m) BNC to BNC Coaxial Cable for Remote Antenna Mounting for ULX
Wireless System|
UA806
25 ft. BNC-BNC Coaxial Cable| UA825
50 ft. BNC-BNC Coaxial Cable| UA850
100 ft. BNC-BNC Coaxial Cable| UA8100
4-to-1 antenna comber with power distribution to 4 transmitters (better RF
perfor-
mance and eliminates need for external power supply)
|
PA421B
---|---
8-to-1 antenna combiner for better RF performance| PA821B
Coiled IFB Earphone Cable for Shure Earphones| EAC-IFB
Frequency Range and Transmitter Output Power
Band | Range | Output Power (mW) |
---|---|---|
G10 | 470–542 MHz | 10/50/100 mW |
G10E | 470–542 MHz | 10/50 mW |
G10J | 470–542 MHz | 6/10 mW |
G11 | 479–542 MHz | 10 mW |
G62 | 510–530 MHz | 10/50 mW |
H8Z | 518–582 MHz | 10/50 mW |
H22 | 518–584 MHz | 10**/50/100 mW |
J8 | 554–626 MHz | 10/50/100 mW |
J8A
| 554–608 MHz| 10/50/100 mW
614–616 MHz| 10* mW
J8E| 554–626 MHz| 10/50 mW
J8J| 554–626 MHz| 6/10 mW
K10E| 596–668 MHz| 10 mW
L8| 626–698 MHz| 10/50/100 mW
L8A
| 653–657 MHz| 10 mW
657–663 MHz| 10* mW
L8E| 626–698 MHz| 10/50 mW
L8J| 626–698 MHz| 6/10 mW
L9E| 670–742 MHz| 10/50 mW
L11J| 670–714 MHz| 6/10 mW
M19| 694–703 MHz| 10/50 mW
P8| 710–790 MHz| 10/50/100 mW
Q12| 748–758 MHz| 10/50 mW
Band| Range| Output Power (mW)
---|---|---
Q21| 710–787 MHz| 10/50/100 mW
Q22E| 750–822 MHz| 10/50/100 mW
R27| 794–806 MHz| 10/50 mW
X1| 944–952 MHz| 10/50/100 mW
X7| 925–937.5 MHz| 10 mW
X55| 941–960 MHz| 10/50/100 mW
NOTE: This Radio equipment is intended for use in musical professional entertainment and similar applications. This Radio apparatus may be capable of oper- ating on some frequencies not authorized in your region. Please contact your national authority to obtain information on authorized frequencies and RF power levels for wireless microphone products.
WARNING: As of January 01, 2019 the use of radio transmitters in the bands 694 – 823 MHz is prohibited.
P10T
Certified under FCC Part 74.
*Certified under FCC Part 15.
**Certified under FCC Part 15 and Part 74.
Certified by ISED in Canada under RSS-123 and RSS-102.
Meets essential requirements of the following European Directives:
- WEEE Directive 2012/19/EU, as amended by 2008/34/EC
- RoHS Directive EU 2015/863
Note: Please follow your regional recycling scheme for batteries and electronic waste
This product meets the Essential Requirements of all relevant European directives and is eligible for CE marking.
Australia Warning for Wireless
This device operates under an ACMA class licence and must comply with all the conditions of that licence including operating frequencies. Before 31 December 2014, this device will comply if it is operated in the 520-820 MHz frequency band.
WARNING: After 31 December 2014, in order to comply, this device must not be operated in the 694-820 MHz band.
Switzerland Warning for Wireless
WARNING: As of January 01, 2019 the use of radio transmitters in the
bands 694 – 823 MHz is prohibited.
Hereby, Shure Incorporated declares that the radio equipment is in compliance
with Directive 2014/53/EU. The full text of the EU declaration of conformity
is available at the following internet address:
http://www.shure.com/europe/compliance
Authorized European representative:
Shure Europe GmbH
Headquarters Europe, Middle East & Africa Department: EMEA Approval
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: +49-7262-92 49 0
Fax: +49-7262-92 49 11 4
Email: EMEAsupport@shure.de
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>