Installation and Safety Instructions Outdoor Wall Light Fitting
Safety Warnings
These instructions are for your safety. Please read through them thoroughly
before use and retain them for future reference. If you are in any doubt about
installing this product, consult a qualified electrician.
This product is only suitable for connection to a 220-240V~ 50Hz supply in
accordance with current IEE wiring regulations, and should be installed in
accordance with local building regulations.
This product is suitable for use outdoors but should not be immersed in water
/ sited in areas likely to be heavily splashed, either from above or below, or
subjected to standing water. If being fitted in a bathroom, this product is
suitable for bathroom outside zones as specified by the right diagram.
The appliance must be supplied through a residual current device (RCD) having
a rated residual operating current not exceeding 30mA.
This product is rated IP44( definition e.g. splash proof / rain proof etc).
Ensure that the screws and cable entry points are sealed to maintain the IP
rating of the product.
This is a Class l product and must be Earthed. The terminal blocks are
supplied according to requirements of the fitting.
IMPORTANT: Always switch off the mains supply during installation or
maintenance. We recommend that the fuse is withdrawn or the circuit breaker
switched off at the distribution board whilst work is in progress (turning off
the light switch is not sufficient). Connection should be via a wall switch to
enable safe isolation.
The product must be securely fixed to the mounting surface using the screws
and wall plugs supplied. The screws and wall plugs supplied are suitable for
“masonry” only. Other fixings are not supplied and must be purchased.
Decide on the position of the light fitting or remove existing light fitting.
Note the position of the electrical connections, and ensure there is a solid
mounting surface, Preferably a wooden joist or joist bridge, to support the
weight of the light fitting.
Take care not to drill into any pipes or mains cables beneath the surface
during mounting holes preparation.
Never put anything on the product or hang anything on any part of this
product.
IMPORTANT: Ensure that all electrical connections are tight and that no
loose strands are left out of the terminal.
Never fit bulbs of a higher wattage than those specified on the label (as
these may cause over heating and damage the fitting).
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your Local Authority or
local store for recycling advice.
Care and maintenance
For bulb replacement, switch off the product (preferably, isolate it at the
distribution board) and allow it to cool down (Caution: bulb gets hot during
use).
Clean with a dry cloth only. Do not use liquid or abrasive cleaners on this
product.
Troubleshooting
When the bulb does not light after installation:
- Ensure there is no electricity failure.
- Ensure all the connections are secure.
If you have any doubt about installation/use of this product, consult a qualified electrician.
PIR Adjustment
To access the adjustment screws flip down the black cover over the PIR sensor.
Take great care when adjusting the sensor screws not to over tighten as they
can be easily broken.
- The unit must be installed in a vertical position, and fitted 1.5-2.0m above the ground.
- The PIR sensor can be adjusted, allowing the detection distance to be altered to suit the location. The detection angle is set at 110º. The duration that lamp stays on can also be altered from
5 seconds – 5 minutes. The LUX range is 10 lux – Daylight. Use a small screwdriver to adjust the “TIME” and “SENS” screws. When adjusting the sensitivity (detection distance) in daylight it will be necessary to cover the sensor to simulate night time.
The PIR sensor has a manual override function which can be operated by taking the following steps:
- When first switched on, the PIR sensor warms up for approx. 1 minute and then goes into AUTO mode.
- In AUTO mode, switch the power OFF and ON twice within 3 seconds, the PIR sensor will switch to MANUAL mode. In MANUAL mode, the light will remain ON permanently, without the PIR function.
- To return to AUTO mode, switch the power OFF and ON twice within 3 seconds.
- In either mode, if the power is switched OFF more than 6 seconds, the PIR sensor will go through ‘warm up’ process again when you turn it on next time.