GERMAN POOL TFT Series Slide Out Type Range Hood User Manual
- July 14, 2024
- GERMAN POOL
Table of Contents
GERMAN POOL TFT Series Slide Out Type Range Hood
Technical Specifications
- Model:
- TFT-600
- TFT-700
- TFT-900
- Voltage/Frequency:
- TFT-600: 220-240 V/50 Hz
- TFT-700: 220-240 V/50 Hz
- TFT-900: 220-240 V/50 Hz
- Power (Max): 247 W
- Lighting: 2 x 3.5 W
- Speed Selection: 2 speeds
- Sound Level/Exhaust Flow (Max): 65 dB / 1200 m3/hr
- Dimensions Exhaust Outlet Diameter:
- (H) 273 mm, (W) 600 mm, (D) 460 mm – TFT-600
- (H) 273 mm, (W) 700 mm, (D) 460 mm – TFT-700
- (H) 273 mm, (W) 900 mm, (D) 460 mm – TFT-900
- Net Weight:
- 10 kg – TFT-600
- 12 kg – TFT-700
- 16.5 kg – TFT-900
Installation
Warning: Failure to install the screws or fixing device according to
instructions may result in electrical hazards.
Before Installation:
- Switch off electricity supply and check voltage and frequency match the appliance nameplate.
- Connect hood plug to power socket following regulations or consult an electrician.
FAQ
Q: How often should I clean the filters?
A: It is recommended to clean the filters every 2-3 months for optimal
performance.
TFT-600 / TFT-700 / TFT-900
Please read these instructions and warranty information carefully before use
and keep them handy for future reference.
USER MANUAL
Please register your warranty information now!
For Warranty Terms & Conditions, please refer to the last page of this user
manual.
Dear Customer,
Thank you for buying our hood. Please read these instructions carefully for
its optimum installation, use and maintenance.
INSTALLATION
Notice before installation
- This hood is designed for fitting in a cabinet or on some other support.
- Warning: consult local regulations regarding fumes outlets. Do not connect the hood to a fume, ventilation or hot air duct. Confirm that room ventilation is appropriate with the local authorities. Make sure the maximum air extraction flow rate for the appliances in the room does not exceed 4 Pa (0.04 mbar). The room must have adequate ventilation if an extractor hood is used simultaneously with appliances that run on gas or other fuels. The evacuated air must be extracted through ducts that are used for evacuating fumes from appliances that run on gas or other fuels. Regulations regarding air extraction must be complied with.
- This product is intended for HOUSEHOLD USE only.
- Use a rigid PVC pipe or aluminium pipe with a min. Ø l25 mm or Ø l52 mm to evacuate fumes outside. The above restrictions do not apply to hoods with no fumes outlet to outside (recirculation system with activated charcoal filter).
- Install the hood in line with the instructions on the template. For gas cooking appliances only: the minimum distance to the hood must be at least 65 cm.
- Warning: Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards.
Installation
The cooker hood is supplied with
- 2 pipe conectors Ø l25 mm or Ø l52 mm
- 3 Spacer (F, H)
- 4 Screws (C)
- 2 Bulbs (LED)
- To fixing the Hood, use the 4 screws (C)φ6mm supplied with the hood.
- Close the space that remains between the hood and the wall, adjusting the spacer (F).
- Before completing any connection, make sure the house voltage corresponds with the voltage indicate on the data label.
- Connecting the hood to the grid
- Warning: before connecting the hood: switch off the electricity supply and check
- that the supplied voltage and frequency coincide with that indicated on the appliance nameplate.
- If the extractor hood has a plug, connect it to a power socket in line with applicable regulations, located in an accessible area.
- If the terminals of the plug are unmarked or if you are in any doubt consult a qualified electrician.
- If it is not supplied fit a plug normalized in the cord for the load showed on the rating label.
OPERATION INSTRUCTIONS
Notice before use
- Warning: the hood may stop working during an electrostatic discharge (e. g. lightning). This involves no risk of damage. Switch off the electricity supply to the hood and reconnect after one minute.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- To avoid the risk of fire, clean the metal filter regularly, permanently control pans containing hot oil and do not flambé food underneath the hood.
- Do not use the hood if it shows signs of damage or imperfection. Contact an official distributor or authorized dealer.
- Accessible parts may heat up when using cooking appliances.
Control panel
- C1 Extractor on and off
- C2 Two extractor speeds
Suction Version
If the hood is to be installed as a SUCTION hood, connect the plastic outlet
piece (A) supplied with the hood (152mm diameter pipe for better performance
and lower noise levels.
Filtering Version (optional accessory)
When there is no exhaust duct for venting out-door, you can use a carbon
filter (B/D). The air is depurate by the filter and put again in the
surrounding.
The air is released in the room through a connecting pipe, which goes through the hanging cupboard and us connected to the connecting ring supplied (A) Fig
- To use the appliance in this version, proceed as follows:
Open the metal grids (E)
To proceed to change the charcoal filter (B/D), uscrew the screw and remove
the grids.
CARE & MAINTENANCE
Hood maintenance
- Warning: always switch off the electricity supply before carrying out maintenance work on the hood. In the event of a fault, contact an official distributor or authorized dealer.
- Exterior cleaning: use non-corrosive, liquid detergent and avoid the use of abrasive cleaning products.
- Grease filters: to avoid fires, clean thoroughly once a month. To do so, remove the filters and wash with hot water and detergent. If using a dishwasher, position the filters vertically to prevent solid remains from depositing on them. Do not use polish to clean or shine.
- Activated charcoal filters: replace the every 3 months. (optional accessory)
- Important: increase the filter cleaning/replacement frequency if the hood is used for more than 2 hours a day. Always use genuine filters from the manufacturer.
Bulb replacement
- Warning: do not handle the bulbs until the electricity supply has been switched off and they have cooled.
- Important: use new bulbs according to that indicated on the hood nameplate.
- On cooker hoods equipped with lamps, the lights should only be used during operation of the motor. They should not be left on permanently and used as a light source.
TECHNICAL SPECIFICATIONS
Model | TFT-600 | TFT-700 | TFT-900 |
---|---|---|---|
Voltage/ Frequency | 220-240 V/50 Hz | 220-240 V/50 Hz | 220-240 V/50 Hz |
Power (Max) | 247 W | 247 W | 247 W |
Lighting | 2 x 3.5 W | 2 x 3.5 W | 2 x 3.5 W |
Speed Selection | 2 speeds | 2 speeds | 2 speeds |
Sound Level | 65 dB | 65 dB | 65 dB |
Exhaust Flow (Max) | 1200 m3/hr | 1200 m3/hr | 1200 m3/hr |
Dimensions
| (H) 273 mm
(W) 600 mm
(D) 460 mm
| (H) 273 mm
(W) 700 mm
(D) 460 mm
| (H) 273 mm
(W) 900 mm
(D) 460 mm
Exhaust Outlet Diameter| Ø125 mm / Ø150 mm| Ø125 mm / Ø150 mm| Ø125 mm / Ø150
mm
Net Weight| 10 kg| 12 kg| 16.5 kg
Specifications are subject to change without prior notice.
If there is any inconsistency or ambiguity between the Chinese version and the
English version, the English version shall prevail. Refer to
www.germanpool.com for the most up-to-date
version of the User Manual.
The manufacturer :
- Declares that this product meets all basic requirements regarding low-voltage electrical equipment established in Directive 2006/95/EC of 12 December 2006 and electro-magnetic compatibility established in Directive 2004/108/EC of 15 December 2004.
- Is not responsible for any failure to observe the instructions given in this manual and current safety regulations for the correct use of the equipment.
- Reserves the right to make any modifications to the equipment or this manual without prior notice.
German Pool (Hong Kong) Limited
8th, Xinxiang Road, Wusha Industrial Park, Daliang, Shunde, Foshan, Guangdong,
China電話 Tel: +86 757 2980 6888
Fax: +86 757 2980 8318
© All rights reserved. Copying, reproducing or using the contents of this manual is not allowed without prior authorization from German Pool, violators will be prosecuted.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>