COREMORROW E53.A Series Piezo Controller User Manual
- June 3, 2024
- COREMORROW
Table of Contents
E53.A Series Piezo Controller
User Manual
E53.A Series Piezo Controller
E53.A Series Piezo Controller
User Manual
Version: V1.0
This document describes the following products:
E53.A
Open loop
1 channel
DECLARATION
Declaration!
This user manual is a integrated user manual of the E53.A series piezoelectric
controller. Please read this user manual carefully before using this
controller. Follow the instructions in the manual during use. If there is any
problem, please contact us for technical support. If you do not follow this
manual or disassemble and modify the product yourself, the company will not be
liable for any consequences arising therefrom. Please read the following to
avoid personal injury and to prevent damage to this product or any other
product connected to it. In order to avoid possible hazards, this product can
only be used within the specified range.
Notice!
Do not touch any exposed ends of the product and its accessories. There is
high voltage inside. Do not open the case without permission. Do not connect
or disconnect input, output, or sensor cables with power on. Please keep
surface of E53.A clean and dry, don’t operate in humid or static environment.
After use, output voltage should be cleared to zero before turning off the
controller switch, such as switching the servo state to the open-loop state.
Danger!
The piezoelectric power amplifier described in this manual is a high-voltage
device capable of outputting high currents, which can cause serious or even
fatal damage if not used properly. It is strongly recommended that you do not
touch any parts that connect to the high voltage output. Special Note: If you
connect it with other products in addition to our company, please follow the
general accident prevention procedures. Operating the high-voltage
amplification requires training professional operators.
Warning!
If the voltage exceeds the PZT’s tolerable range, it will cause permanent
damage to the PZT. Before adding voltage to the PZT poles, it must be ensured
that the positive and negative poles of the PZT are connected correctly and
the operating voltage is within the allowable range of this PZT.
Cautious!
E53.A housing should be installed on a horizontal surface in an area with a
3CM air flow area to prevent internal convection in the vertical direction.
Insufficient airflow can cause equipment to overheat or premature instrument
damage.
Introduction
1.1 Features
- 1 channel small size
- 24V20~30V1.5A 36W
- Peak current 1A
- Ave current 60mA
- Unload bandwidth 10KHz
- Output short circuit protection
1.2 Applicaitons
- Driving piezo actuators
- Driving piezo objective scanners
1.3 Order information
- E53.A—-Open loop Accept customized according to requirements
12bit gain/-20 120V output voltagedefault
15bit gain/-20 150V output voltage
Driving Principle
Appearance
Power Calculation
Average outputSine wave operation mode
Pa≈ Upp · Us · f· Cpiezo
Pa=Average output[W] Cpiezo=Piezo actuator capacitance[F] Upp=Peak and peak
drive voltage [V] f=Operating frequency of the sine wave[Hz] Us=Drive
voltage[V]Vs+-Vs-
Frequency, Ouput Voltage and Load Curves
Panel Introduction
No. | Function |
---|---|
① | Power switch |
② | Power indicator |
③ | Power |
④ | Driving output |
⑤ | Overcurrent indicator |
⑥ | Analog input |
Drawings
Notes and suggestions
- E53.A cannot be used to drive inductive loads. If the inductive loads are driven, the product may be damaged.
- If there is no need, please do not twist the potentiometer easily.
Contact us
Harbin Core Tomorrow Science & Technology Co., Ltd.
Tel: +86-451-86268790
Email: info@coremorrow.com
Website: www.coremorrow.com
Address: Building I2, No.191 Xuefu Road
Nangang District, Harbin, HLJ, China CoreMorrow
Official and CTO WeChat are below:
http://weixin.qq.com/r/PEzawqnEyfS2re2h9xku
https://u.wechat.com/EAOWfcTPsTfQdVIeK41V9hg
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>