STP5.0-3SE-40 Sunny Tripower Smart Energy User Guide
- July 13, 2024
- SMA
Table of Contents
SUNNY TRIPOWER 5.0 / 6.0 / 8.0 / 10.0 SMART ENERGY
STP5.0-3SE-40 / STP6.0-3SE-40 / STP8.0-3SE-40 / STP10.0-3SE-40 123897-00.01###
eManual
https://manuals.sma.de/STPxx3SE40/index.html
STPx.0-3SE-40-IS-xx-12 | 123897-00.01 | Version 1.2
Quick Reference Guide
Information on this Document
1.1 Validity
This document is valid for:
- STP5.0-3SE-40
- STP6.0-3SE-40
- STP8.0-3SE-40
- STP10.0-3SE-40
1.2 Target Group
The tasks described in this document must only be performed by qualified
persons. Qualified persons must have the following skills:
- Knowledge of how to safely disconnect SMA inverters
- Knowledge of how an inverter works and is operated
- Knowledge of how batteries work and are operated
- Training in how to deal with the dangers and risks associated with installing, repairing and using electrical devices, batteries and installations
- Training in the installation and commissioning of electrical devices and installations
- Knowledge of all applicable laws, standards and directives
- Knowledge of and compliance with this document and all safety information
- Knowledge of and compliance with the documents of the battery manufacturer with all safety information
1.3 Content and Structure of this Document
This document contains safety information as well as graphical instructions on
installing and commissioning (see page 253). Observe all information and carry
out the actions illustrated graphically in this document in the specified
order.
The latest version of this document and the comprehensive manual for
installation, commissioning, configuration and decommissioning are to be found
in PDF format and as eManual at www.SMASolar.com.
You will find the QR code that links to the eManual on the title page of this
document. You can also call up the eManual via the user interface of the
product.
Illustrations in this document are reduced to the essential information and
may deviate from the real product.
1.4 Levels of warning messages
The following levels of warning messages may occur when handling the product.
DANGER
Indicates a hazardous situation which, if not avoided, will result in death
or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death
or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor
or moderate injury.
NOTICE
Indicates a situation which, if not avoided, can result in property damage.
1.5 Symbols in the Document
Icon | Explanation |
---|---|
Information that is important for a specific topic or goal, but is not |
safety-relevant
| Section in which the installation and commissioning process is illustrated
graphically.
Safety
2.1 Intended Use
The Sunny Tripower Smart Energy is a transformerless hybrid inverter with 2
MPP trackers and a battery connection that feeds the direct current of the PV
array into the connected battery or converts it to grid-compliant three-phase
current and then feeds it into the utility grid. The Sunny Tripower Smart
Energy also converts the direct current supplied by the battery into
gridcompliant three-phase current. In a system with additional PV inverters,
the Sunny Tripower Smart Energy can convert the three-phase current generated
by the PV inverters into direct current and feed it into the battery.
The Sunny Tripower Smart Energy has a backup function. In the event of a power
outage, the Sunny Tripower Smart Energy can continue to supply selected
circuits with power from the battery or PV system.
The product is suitable for indoor and outdoor use.
The product must only be operated with PV modules of protection class II in
accordance with IEC 61730, application class A. The PV modules must be
compatible with this product.
The product is not equipped with an integrated transformer and therefore has
no galvanic isolation. The product must not be operated with PV modules whose
outputs are grounded. This can cause the product to be destroyed. The product
may be operated with PV modules whose frame is grounded.
The product must only be operated in connection with an intrinsically safe
lithium-ion battery approved by SMA Solar Technology AG. An updated list of
batteries approved by SMA Solar Technology AG is available at www.SMA-
Solar.com.
The battery must comply with the locally applicable standards and directives
and must be intrinsically safe (see technical information “SMA Flexible
Storage System – Detailed explanations of the safety concept” for detailed
explanations regarding the safety concept of battery inverters by SMA Solar
Technology AG).
The communication interface of the battery used must be compatible with the
product. The entire battery voltage range must be completely within the
permissible input voltage range of the product.
The maximum permissible DC input voltage of the product must not be exceeded.
The product is not suitable for supplying life-sustaining medical devices. A
power outage must not lead to personal injury.
All components must remain within their permitted operating ranges and their
installation requirements at all times.
The product must only be used in countries for which it is approved or
released by SMA Solar
Technology AG and the grid operator.
The product may only be operated with one of the energy meters approved by SMA
Solar
Technology AG. The following energy meters are allowed to be used when
operating this product:
- EMETER-20 (SMA Energy Meter)
- HM-20 (Sunny Home Manager 2.0)
Use SMA products only in accordance with the information provided in the
enclosed documentation and with the locally applicable laws, regulations,
standards and directives. Any other application may cause personal injury or
property damage.
Alterations to SMA products, e.g., changes or modifications, are only
permitted with the express written permission of and according to the
instructions from SMA Solar Technology AG. Unauthorized alterations can be
dangerous and lead to personal injury. In addition, an unauthorized alteration
will void guarantee and warranty claims and in most cases terminate the
operating license. SMA Solar Technology AG shall not be held liable for any
damage caused by such changes.
Any use of the product other than that described in the Intended Use section
does not qualify as appropriate.
The enclosed documentation is an integral part of this product. Keep the
documentation in a convenient, dry place for future reference and observe all
instructions contained therein.
This document does not replace any regional, state, provincial, federal or
national laws, regulations or standards that apply to the installation,
electrical safety and use of the product. SMA Solar Technology AG assumes no
responsibility for the compliance or non-compliance with such laws or codes in
connection with the installation of the product.
The type label must remain permanently attached to the product.
2.2 IMPORTANT SAFETY INSTRUCTIONS
Keep the manual for future reference.
This section contains safety information that must be observed at all times
when working.
The product has been designed and tested in accordance with international
safety requirements. As with all electrical or electronical devices, there are
residual risks despite careful construction. To prevent personal injury and
property damage and to ensure long-term operation of the product, read this
section carefully and observe all safety information at all times.
DANGER
Danger to life due to electric shock when touching live system components
in backup mode
Even if the AC miniature circuit breaker and the DC load-break switch of the
inverter are disconnected, parts of the system may still be live when the
battery is switched on due to backup mode.
- Prior to performing any work on the inverter, disconnect it from all voltage sources as described in this document.
DANGER
Danger to life due to electric shock when live components or DC cables are
touched when working on the battery
The DC cables connected to the battery may be live. Touching live DC cables
results in death or serious injury due to electric shock.
- Prior to performing any work on the battery, disconnect the inverter from all voltage sources as described in this document.
DANGER
Danger to life due to electric shock when live components or DC cables are
touched.
The DC cables connected to a battery or a PV module may be live. Touching live
DC cables results in death or serious injury due to electric shock.
- Disconnect the product and battery from voltage sources and make sure it cannot be reconnected before working on the device.
- Observe all safety information of the battery manufacturer.
- Do not touch non-insulated parts or cables.
- Do not disconnect the DC connectors under load.
- Wear suitable personal protective equipment for all work on the product.
DANGER
Danger to life due to electric shock when live components are touched on
opening the product.
High voltages are present in the live parts and cables inside the product
during operation.
Touching live parts and cables results in death or lethal injuries due to
electric shock.
- Do not open the product.
DANGER
Danger to life due to electric shock when touching live system components
in case of a ground fault
If a ground fault occurs, parts of the system may still be live. Touching live
parts and cables results in death or lethal injuries due to electric shock.
- Disconnect the product and battery from voltage sources and make sure it cannot be reconnected before working on the device.
- Only touch the cables of the PV modules on their insulation.
- Do not touch any parts of the substructure or frame of the PV array.
- Do not connect PV strings with ground faults to the inverter.
DANGER
Danger to life due to electric shock in case of overvoltages and if surge
protection is missing
Overvoltages (e. g. in the event of a flash of lightning) can be further
conducted into the building and to other connected devices in the same network
via the network cables or other data cables if there is no surge protection.
Touching live parts and cables results in death or lethal injuries due to
electric shock.
- Ensure that all devices in the same network and the battery are integrated into the existing surge protection.
- When laying the network cables or other data cables outdoors, it must be ensured that a suitable surge protection device is provided at the transition point of the cable from the product or the battery outdoors to the inside of a building.
- The Ethernet interface of the product is classified as “TNV-1” and offers protection against overvoltages of up to 1.5 kV.
WARNING
Danger to life due to fire and explosion
In rare cases, an explosive gas mixture can be generated inside the product
under fault conditions. In this state, switching operations can cause a fire
inside the product or explosion.
Death or lethal injuries due to hot or flying debris can result.
- In the event of a fault, do not perform any direct actions on the product.
- Ensure that unauthorized persons have no access to the product.
- Do not operate the DC load-break switch on the inverter in case of an error.
- Disconnect the PV array from the inverter via an external disconnection device. If there is no disconnecting device present, wait until no more DC power is applied to the inverter.
- Disconnect the battery from the product via an external disconnection device. Do not operate the DC load-break switch on the product.
- Disconnect the AC circuit breaker, or keep it disconnected in case it has already tripped, and secure it against reconnection.
- Only perform work on the product (e.g., troubleshooting, repair work) when wearing personal protective equipment for handling of hazardous substances (e.g., safety gloves, eye and face protection, respiratory protection).
WARNING
Risk of injury due to toxic substances, gases and dusts.
In rare cases, damages to electronic components can result in the formation of
toxic substances, gases or dusts inside the product. Touching toxic substances
and inhaling toxic gases and dusts can cause skin irritation, burns or
poisoning, trouble breathing and nausea.
- Only perform work on the product (e.g., troubleshooting, repair work) when wearing personal protective equipment for handling of hazardous substances (e.g., safety gloves, eye and face protection, respiratory protection).
- Ensure that unauthorized persons have no access to the product.
WARNING
Danger to life due to fire or explosion when batteries are fully discharged
A fire may occur due to incorrect charging of fully discharged batteries. This
can result in death or serious injury.
- Before commissioning the system, verify that the battery is not fully discharged.
- Do not commission the system if the battery is fully discharged.
- If the battery is fully discharged, contact the battery manufacturer for further proceedings.
- Only charge fully discharged batteries as instructed by the battery manufacturer.
WARNING
Danger to life due to burns caused by electric arcs through short-circuit
currents
Short-circuit currents in the battery can cause heat build-up and electric
arcs. Heat build-up and electric arcs may result in lethal injuries due to
burns.
- Disconnect the battery from all voltages sources prior to performing any work on the battery.
- Observe all safety information of the battery manufacturer.
WARNING
Danger to life due to electric shock from destruction of the measuring
device due to overvoltage
Overvoltage can damage a measuring device and result in voltage being present
in the enclosure of the measuring device. Touching the live enclosure of the
measuring device results in death or lethal injuries due to electric shock.
- Only use measuring devices with a DC input voltage range of 1000 V or higher.
CAUTION
Risk of burns due to hot enclosure parts
The enclosure and the enclosure lid may get hot during operation. The DC load-
break switch can not become hot.
- Do not touch hot surfaces.
- Wait until the inverter has cooled down before touching the enclosure or enclosure lid.
CAUTION
Risk of injury due to weight of product
Injuries may result if the product is lifted incorrectly or dropped while
being transported or mounted.
- Transport and lift the product carefully. Take the weight of the product into account.
- Wear suitable personal protective equipment for all work on the product.
NOTICE
Damage to the DC connectors due to the weight of the product
The DC connectors mounted on the product may be damaged if the product is set
down on them.
- Do not set the product down on its DC connectors.
- Do not remove the protective cover from the DC connectors until the product is installed on the wall mounting bracket.
NOTICE
High costs due to inappropriate Internet tariff
Depending on use, the data volume of the product transferred via the Internet
may vary in size. The data volume depends, for example, on the number of
devices in the system, the frequency of device updates, the frequency of data
transfer to Sunny Portal or the use of FTP push. High costs for the Internet
connection can be the result.
- SMA Solar Technology AG recommends using an Internet flat rate.
NOTICE
Damage to the product due to cleaning agents
The use of cleaning agents may cause damage to the product and its components.
- Clean the product and all its components only with a cloth moistened with clear water.
Symbols on the Product
Icon | Explanation |
---|---|
Beware of a danger zone |
This symbol indicates that the product must be additionally grounded if
additional grounding or equipotential bonding is required at the installation
site.
| Beware of electrical voltage
The product operates at high voltages.
| Beware of hot surface
The product can get hot during operation.
| Danger to life due to high voltages in
the inverter; observe a waiting time of 10 minutes.
High voltages that can cause lethal electric shocks are present in the live
components of the inverter.
Prior to performing any work on the inverter, disconnect it from all voltage
sources as described in this document.
| Observe the documentations
Observe all documentations supplied with the product.
| Inverter
Together with the green LED, this symbol indicates the operating state of the
inverter.
| Observe the documentations
Together with the red LED, this symbol indicates an error.
| Data transmission
Together with the blue LED, this symbol indicates the status of the network
connection.
| The product has no galvanic isolation.
| Direct current
| Three-phase alternating current with neutral conductor
| WEEE designation
Do not dispose of the product together with the household waste but in
accordance with the disposal regulations for electronic waste applicable at
the installation site.
| The product is suitable for outdoor installation.
IP65| Degree of protection IP65
The product is protected against the penetration of dust and water that is
directed as a jet against the enclosure from all directions.
| CE marking
The product complies with the requirements of the applicable EU directives.
| UKCA marking
The product complies with the regulations of the applicable laws of England,
Wales and Scotland.
| RoHS labeling
The product complies with the requirements of the applicable EU directives.
| RCM (Regulatory Compliance Mark)
The product complies with the requirements of the applicable Australian
standards.
| The product complies with the Moroccan safety and EMC requirements for
electronic products.
EU Declaration of Conformity
within the scope of the EU directives
- Radio Equipment Directive 2014/53/EU (22.5.2014 L 153/62) (RED)
- Restriction of the use of certain hazardous substances 2011/65/EU (L 174/88, June 8, 2011) and 2015/863/EU (L 137/10, March 31, 2015) (RoHS)
SMA Solar Technology AG confirms herewith that the products described in this document are in compliance with the fundamental requirements and other relevant provisions of the abovementioned directives. The entire EU Declaration of Conformity can be found at www.SMASolar.com.
UK Declaration of Conformity
according to the regulations of England, Wales and Scotland
- Radio Equipment Regulations 2017
- The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
SMA Solar Technology AG confirms herewith that the products described in this document are in compliance with the fundamental requirements and other relevant provisions of the abovementioned regulations. The entire UK Declaration of Conformity can be found at www.SMASolar.com.
Instructions
Scope of Delivery
Mounting location
Mounting
AC Connection
AC| STP5.0-3SE-40| STP6.0-3SE-40| STP8.0-3SE-40|
STP10.0-3SE-40
---|---|---|---|---
P AC (@ 230 V, 50 Hz)| 5000 W| 6000 W| 8000 W| 10000 W
S AC (@ cos φ = 1)| 5000 VA| 6000 VA| 8000 VA| 10000 VA
V AC, r| 3/N/PE, 220 V / 380 V, 230 V / 400 V, 240 V / 415 V
V AC, range| 156 V to 277 V
I AC (@ 230 V, 50 Hz)| 7.3 A| 8.7 A| 11.6 A| 14.5 A
I AC,max| 7.6 A| 9.1 A| 12.1 A| 15.2 A
f AC| 50 Hz
cos φ| 0.8 overexcited to 0.8 underexcited
Connecting the network
Connecting the COM Plug
Connecting the PV Array
DC| STP5.0-3SE-40| STP6.0-3SE-40| STP8.0-3SE-40|
STP10.0-3SE-40
---|---|---|---|---
P DC, max, generator| 7500 Wp| 9000 Wp| 12000 Wp| 15000 Wp
P DC, max, per string| 6000 W
V DC, max| 1000 V
V DC, MPP| 150 V to 800 V
V DC, r| 600 V
I DC, max| 12.5 A / 12.5 A| 12.5 A / 12.5 A| 12.5 A / 12.5 A| 12.5 A / 25 A
I SC PV| 20 A / 20 A| 20 A / 20 A| 20 A / 20 A| 20 A / 40 A
Connecting the battery
Battery| STP5.0-3SE-40| STP6.0-3SE-40| STP8.0-3SE-40|
STP10.0-3SE-40
---|---|---|---|---
Type| Li-ion battery
V DC, max| 600 V
V DC, min| 150 V
I DC, max| 30 A
Commissioning
Accessing the user interface via WLAN
Accessing the user interface via LAN
Configuration
Disconnect from voltage sources
System data
Topology | no galvanic isolation |
---|---|
Overvoltage category in accordance with IEC 60664-1 | II (DC), III (AC) |
Protection class in accordance with IEC 61140 | I |
All-pole sensitive residual-current monitoring unit | integrated |
Maximum permissible value for relative humidity, condensing | 100% |
Extended humidity range according to IEC 60721-3-4 | 0 % to 100 % |
Pollution degree inside the enclosure | 2 |
Pollution degree outside the enclosure | 3 |
Radio technology | WLAN 802.11 b/g/n |
Radio spectrum | 2.4 GHz |
Maximum transmission power | 100 mW |
Demand Response Mode per AS/NZS 4777 | DRM0 |
Power control/Demand Response (DRED) | Communication via Modbus |
Contact
https://go.sma.de/service
STPx.0-3SE-40-IS-xx-12www.SMA-
Solar.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>