MEAN WELL RPD-60 Series 60W Dual Output Medical Grade Owner’s Manual

July 9, 2024
MEAN WELL

MEAN WELL RPD-60 Series 60W Dual Output Medical Grade

Specifications

  • Model: RPD-60A, RPD-60B
  • Output Voltage:
    • CH1: 5V, 5A (0.5 ~ 5.5A)
    • CH2: 12V, 2A (0.1 ~ 2.2A) or 24V, 1.5A (0.1 ~ 1.65A)
  • Rated Power:
    • RPD-60A: 49W
    • RPD-60B: 53.5W (peak load: 58.85W)
  • Efficiency: RPD-60A (78%), RPD-60B (82%)
  • Input Voltage Range: 90 ~ 264VAC, 127 ~ 370VDC
  • Frequency Range: 47 ~ 63Hz
  • Safety Standards: IEC 60601-1, TUV BS EN/EN 60601-1, ANSI/AAMI ES60601-1, IEC 62368-1, UL 62368-1
  • Isolation Level: Primary-Secondary: 2xMOPP, Primary-Earth: 1xMOPP, Secondary-Earth: 1xMOPP

Product Usage Instructions

Installation

  1. Ensure the input voltage is within the specified range.
  2. Connect the output voltages according to your application requirements.
  3. Properly ground the power supply as per safety standards.

Operation

  1. Power on the RPD-60 series power supply.
  2. Monitor the output voltages to ensure they meet your device’s requirements.
  3. In case of any abnormalities or faults, refer to the user manual for troubleshooting.

Maintenance

  1. Regularly check for any physical damage to the power supply.
  2. Clean the unit using a dry cloth to prevent dust buildup.
  3. If encounter issues, contact customer support for assistance.

FAQ

Q: What are the protections provided by the RPD-60 series?

A: The RPD-60 series offers protections against short circuits, overload, and overvoltage.

Q: What applications are suitable for the RPD-60 series?

A: The RPD-60 series is suitable for applications such as oral irrigators, hemodialysis machines, medical computer monitors, and sleep apnea devices.

Features

  • 4″×2″ compact size
  • Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1
  • Suitable for BF application with appropriate system consideration
  • Cooling by free air convection
  • EMI Class B for class I configuration
  • Extremely low leakage current
  • Protections: Short circuit / Overload / Over voltage
  • 3 years warranty

Description

  • RPD-60 is a 60W highly reliable green PCB-type medical power supply with a high power density on the 4″ by 2″ footprint. It accepts 90~264VAC input and offers dual output voltages.
  • RPD-60 can be used for Class I (with FG) system design. The extremely low leakage current is less than 150MA. In addition, it conforms to international medical regulations (2*MOPP) and EMC BS EN/EN55011.

Applications

  • Oral irrigator
  • Hemodialysis machine
  • Medical computer monitors
  • Sleep apnea devices

GTIN CODE

Model Encoding

SPECIFICATION

MODEL RPD-60A RPD-60B
OUTPUT OUTPUT NUMBER CH1
DC VOLTAGE 5V 12V
RATED CURRENT 5A 2A
CURRENT RANGE 0.5 ~ 5.5A 0.1 ~ 2.2A
RATED POWER 49W 53.5W
PEAK LOAD(10sec.) Note.2 53.9W 58.85W
RIPPLE & NOISE (max.) **Note.3** 80mVp-p 80mVp-p
VOLTAGE TOLERANCE Note.4 +3,-2% ±6.0%
LINE REGULATION ±0.5% ±1.0%
LOAD REGULATION ±1.5% ±2.0%
SETUP, RISE TIME 300ms, 15ms/230VAC            300ms, 15ms/115VAC at

full load
HOLD UP TIME (Typ.)| 70ms/230VAC            14ms/115VAC at full load
INPUT| VOLTAGE RANGE| 90 ~ 264VAC          127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 78%| 82%
AC CURRENT (Typ.)| 1.1A/115VAC             0.7 A/230VAC
INRUSH CURRENT (Typ.)| COLD START 60A/230VAC           30A/115VAC
LEAKAGE CURRENT Note.5| Earth leakage current < 150μA/264VAC , Touch current < 100μA/264VAC
PROTECTION| OVERLOAD| 115 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVERVOLTAGE| CH1: 5.75 ~ 6.75V
Protection type: Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -20 ~ +65℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 45℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along the X, Y, and Z axes
OPERATING ALTITUDE Note.6| 3000 meters
SAFETY & EMC

(Note 9)

| SAFETY STANDARDS| IEC 60601-1:2005+A1, TUV BS EN/ EN 60601-1:2006+A1+A12+A2, ANSI/AAMI ES60601-1:2005+A2,

CAN/CSA C22.2 No. 60601-1:2014+A2, IEC 62368-1:2014, UL 62368-1, 2nd Ed, CSA C22.2 No. 62368-1-14, 2nd Ed, TUV BS EN/ EN 62368-1:2014+A11, EAC TP TC 004 approved

ISOLATION LEVEL| Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP
WITHSTAND VOLTAGE| I/P-O/P:4KVAC  I/P-FG:2KVAC  O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted emission| BS EN/EN55011 (CISPR11)| Class B
Radiated emission| BS EN/EN55011 (CISPR11)| Class B
Harmonic current| BS EN/EN61000-3-2| Class A
Voltage flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN55035,BS EN/EN60601-1-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 4, 15KV air ; Level 4, 8KV contact
RF field susceptibility| BS EN/EN61000-4-3| Level 3, 10V/m( 80MHz~2.7GHz )

Table 9, 9~28V/m( 385MHz~5.78GHz )

EFT bursts| BS EN/EN61000-4-4| Level 3, 2KV
Surge susceptibility| BS EN/EN61000-4-5| Level 4, 4KV/Line-FG ; 2KV/Line-Line
Conducted susceptibility| BS EN/EN61000-4-6| Level 3, 10V
Magnetic field immunity| BS EN/EN61000-4-8| Level 4, 30A/m
Voltage dip, interruption| BS EN/EN61000-4-11| 100% dip 1 period, 30% dip 25 periods, 100% interruptions 250 periods
OTHERS| MTBF| 5031.3K hrs min.       Telcordia SR-332 (Bellcore); 679.5K hrs min.        MIL-HDBK-217F (25℃)
DIMENSION (LWH)| 101.650.829mm or 4″ 2″ 1.14″ inch
PACKING| 0.15Kg; 96pcs/15.4Kg/0.89CUFT
NOTE| 1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 2 ℃ of ambient temperature.

2.  33% Duty cycle maximum within every 30 seconds. The average output power should not exceed the rated power.

3.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.

4.  Tolerance: includes set up tolerance, line regulation, and load regulation.

Touch current was measured from primary input to DC output.

6.  The ambient temperature derating of 3. ℃/1000m with fanless models and of ℃/1000m with fan models for operating altitudes higher than 2000m 6 00ft.

7.  Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to an increase in the set-up time.

8.  Heat Sink HS1,HS2 can not be shorted.

9.  The power supply is considered a component that will be installed into the final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

※ Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

Derating Curve

Output Derating VS Input Voltage

Mechanical Specification

AC Input Connector (CN1) : JST B3P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 AC/N JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
2 No Pin
3 AC/L

DC Output Connector (CN2) : JST B6P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1,2 V1 JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
3,4 COM
5 V2
6 NC

~~~~Grounding Required

  1. HS1, HS2 cannot be shorted.
  2. M1 is safety ground. For better EMC performance, Please secure an electrical connection between
    • M1, M2, and chassis grounding.
    • M1 M2

Installation Manual

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>