HARVARD MTA XR Flow EWT OptiCaps and EndoDirect Syringe
MTA cement, flowable, with extra long working time and EndoDirect syringe Harvard MTA XR Flow EWT OptiCaps is a biocompatible repair cement in OptiCaps®. Due to it’s flowable consistency in combination with a long working time, Harvard MTA XR Flow EWT SET is the ideal choice for rootend fillings (orthograde). Harvard MTA XR Flow EWT powder consists of very fine hydrophilic particles of several hydraulic mineral oxides. After contact with the liquid it forms a gel that hardens to an impermeable barrier. Harvard MTA XR Flow EWT OptiCaps® are easily activated and the content of the capsule is easily ejected with the Harvard Applier OptiCaps®. Mixing of Harvard MTA XR Flow EWT OptiCaps® (mixing time 30 seconds) is achieved by a high frequency mixer with about 4,300 oscillations/minute.
Indications
- Apexification / Root-end filling (orthograde)
Contraindications/side-effects None known.
Activation and mixing
See “Instructions for the activation and mixing of Harvard OptiCaps®” Mixing
time for the Harvard MTA XR Flow EWT OptiCaps® is 30 seconds.
Attention:
Avoid lag times between the processes of activation, mixing and application as
the material is in the process of setting and lag times may impair or prevent
application of the material. The material must be extruded within 10 seconds
after the end of
mixing. To prevent dehydration during setting, apply Harvard MTA XR Flow EWT
immediately after mixing.
Working time
Working time at 23° C (from the start of mixing): 4:00 minutes
Application
Place rubber dam and clean the root canal system using intracanal instruments
and irrigate with NaOCl. Dry the root canal with paper points. For
disinfection place calcium hydroxide paste in the root canal and seal the
access opening with a temporary filling material. After one week remove the
calcium hydroxide paste from the root canal
system. Check the Harvard MTA EndoDirect syringe for tightness of the endo
tip.
Note: Use only the fitted endo tip in combination with the Harvard MTA
EndoDirect syringe!
Mark the working length with the silicone stop and bent the endo tip – if
desired – at an obtuse angle. Remove the plunger from the syringe. Mix a
capsule of Harvard MTA XR Flow EWT OptiCaps® as described under item 1 and
transfer the mixed material into the Harvard MTA EndoDirect syringe. Apply the
required amount of MTA flow EWT into the apical region. Create a 3 – 5 mm
barrier of MTA cement. Check the position of Harvard MTA XR Flow EWT by an
X-ray. If an adequate barrier has not been created, rinse the MTA cement out
of the canal and repeat the procedure. At the earliest 10 minutes after
application of the Harvard MTA XR Flow EWT place a cotton pellet in the access
to the root canal and apply a temporary filling material. Alternatively seal
the root canal with a suitable root canal filling material and seal the cavity
with a tight filling.
Notes
- In the first hour after application handle the placed MTA cement carefully.
- Store Harvard MTA XR Flow EWT OptiCaps® in the sealed packaging in a dry place prior to use.
- Harvard MTA XR Flow EWT can cause discoloration.
Storage
Store Harvard MTA XR Flow EWT at a dry place at 2 – 25 °C (36 °F – 77 °F). Do not use after expiry date. Harvard MTA XR Flow EWT OptiCaps® are for single use only.
Warranty
Harvard Dental International GmbH warrants this product will be free from
defects in material and manufacture. Harvard Dental International GmbH makes
no other warranties including any implied warranty of merchantability or
fitness for a particular purpose. User is responsible for determining the
suitability of the product for user’s application. If this product is
defective within the warranty period, your exclusive remedy and Harvard Dental
International GmbHs sole obligation shall be repair or
replacement of the Harvard Dental International GmbH product.
Limitation of liability
Except where prohibited by law, Harvard Dental International GmbH will not be liable for any loss or damage arising from this product, whether direct, indirect, special, incidental or consequential, regardless of the theory asserted, including warranty, contract, negligence or strict liability.
For dental use only
Store product out of reach of children
Keep the instructions for use for the duration of the application.
Activation and mixing of Harvard OptiCaps® & EndoDirect syringe
-
Harvard OptiCaps® before activation.
-
For activation of the Harvard OptiCaps®, press the plunger on a hard and plane surface to the end into the capsule.
-
Insert the Harvard OptiCaps® into the Harvard Applier OptiCaps® and and click once.
Note: The plunger must be at the same level as the bottom of the capsule. -
Insert the Harvard OptiCaps® into a standard mixer, close the lid and mi immediately for 30 seconds at 4,300 oscillations/minute.
-
Insert the Harvard OptiCaps® into the Harvard Applier OptiCaps®. Remove the pin from the nozzle. If you leave it, the capsule can burst. Pull the lever 2 times (2 distinct clicks) to prime the the Harvard OptiCaps
-
Check the Harvard MTA EndoDirect syringe for tightness of the endo tip. Mark the working length with the silicone stop and bent the endo tip – if desired – at an obtuse angle.
-
Remove the plunger from the syringe.
-
Transfer the mixed material immediately into the Harvard MTA EndoDirect syringe and apply. Unlock the Harvard Applier OptiCaps® (press button A) and remove the Harvard OptiCaps
-
Place the plunger in the Harvard MTA EndoDirect syringe.
-
Application of Harvard MTA XR Flow EWT into the apical region of the root canal.
Note:
- Use only the fitted endo tip in combination with the Harvard MTA EndoDirect syringe!
- Only with the Harvard capsule applier (Order.-No. 7092000) the optimal amount of mixed material is guaranteed.
- For the selection of a suitable capsule mixer, our sales and marketing colleagues are gladly available to you.