ELRO FS4610 Ultra Dunne Rookmelder User Guide

June 3, 2024
ELRO

SMOKE ALARM
Instrucmanual

ELRO FS4610 Ultra Dunne Rookmelder

reddot award 2019 winner

ELRO FS4610 Ultra Dunne Rookmelder - Fig 1| ELRO
FS4610 Ultra Dunne Rookmelder - Fig 2
---|---

FS4610 Ultra Dunne Rookmelder

INTENDED USE: FIRE SAFETY ESSENTIAL CHARACTERISTICS: PASSED

Nominal acvaon condions/ Sensivity, Response delay (response me) and erformance under fire condion – Operaonal reliability – Tolerance to supply voltage –
Durability of operaonal reliability and response delay, temperature resistance, vibraon resistance, humidity resistance, corrosion resistance, electrical stability

|  Smoke alarm with opcal sensor
---|---
| 10 years, not replaceable
|  Mounting: ceiling, wall
|  Dimmed led signals in dark rooms
|  Alarm silence facility
|  Automatic self test
| Mute battery warning
|  Suitable for caravans
|   Operating temperature
|   Operating humidity
|  Alarm volume
|  Capacity
|  Warranty: www.elro.eu

This smoke alarm is equipped with a self-test mechanism. At least once a month at a random moment, the device automacally checks the funconality of the sensor and the siren. During a successful test, the detector will beep and blink briefly. If problems are detected, the detector switches to error mode. Replace the device immediately if the error message occurs!

Content

ELRO FS4610 Ultra Dunne Rookmelder - Fig 3

Activate

ELRO FS4610 Ultra Dunne Rookmelder - Fig 4

Testing

ELRO FS4610 Ultra Dunne Rookmelder - Fig 5

Rooms

ELRO FS4610 Ultra Dunne Rookmelder - Fig 6

Ceiling/Wall mounting

ELRO FS4610 Ultra Dunne Rookmelder - Fig 7

Test & clean

ELRO FS4610 Ultra Dunne Rookmelder - Fig 8

Alarm silence

ELRO FS4610 Ultra Dunne Rookmelder - Fig 9

Low battery

ELRO FS4610 Ultra Dunne Rookmelder - Fig 10

Overview LED & acousc signalling

Operating mode| Visual signal (flash)| Acoustic signal (beep)| Description mode
---|---|---|---
Normal| 1 x per 40 second| None| Device is functioning properly
Self test| 1 x| 1 x| Device functions correctly
Manual test| 3 x| 3 x| Device functions correctly
Alarm| 1 x per second (3 x) / pause of 1,5 seconds| 1 x per seconds (3 x) / pause of 1,5 seconds| Device is detecting smoke
Alarm silence| 1 x per 8 seconds| None| Smoke alarm signal is muted
Low battery warning| 1 x per 40 seconds| 1 x per 40 seconds| Battery is running low
Low battery warning silence| None| None| Low battery warning is muted
Sensor fault warning| 1 x per 40 seconds| 1 x per 40 seconds| Sensor is not functioning properly
Buzzer fault warning| 2 x per 40 seconds| None| Buzzer is not functioning properly

** FS4610 19
FS4610 DoP 001
1116 Fire Safety
EN 14604:2005 + AC:2008
Manufacturer:**
Siterwell Electronics CO., Limited
No.666 Qingfeng Road, Jiangbei District,
Ningbo, Zhejiang Province, China 315034

Importer
ELRO Europe | www.elro.eu
Postbus 9607 – Box E800
1006 GC Amsterdam The Netherlands