ELRO FZ5010R Smoke Detector Wireless Connected Instruction Manual
- May 15, 2024
- ELRO
Table of Contents
ELRO FZ5010R Smoke Detector Wireless Connected
Specifications
-
Detection method: Optical
-
Power supply: Sealed battery 3V DC
-
Battery lifetime: 10 years
-
Alarm volume: Not specified
-
Monitored area: Residential buildings, apartments, rooms
-
Operating temperature: Not specified
-
Operating humidity: Not specified
-
Date of replacement: 10 years after activation
-
Individual alarm indicator: Yes
-
Alarm silence facility: Yes
-
Low battery warning: Yes
-
Low battery silence facility: Yes
-
Installation in leisure accommodation vehicles: Not
specified -
Mounting location: Ceiling between 30 and 50 centimeters
-
Interconnectable: Yes
-
Wireless frequency: Not specified
-
Wireless distance: Not specified
Product Usage Instructions
Where to Install Smoke Alarms
Install smoke alarms on the ceiling between 30 and 50 centimeters. Avoid
installing them near machines or in areas with special geometries.
Activation
- Set the switch on the mounting plate to position B = ON.
- Replace the smoke alarm 10 years after activation.
Connecting Smoke Alarms
- Choose a master smoke alarm.
- Turn the master smoke alarm into connect mode by quickly pressing the test button 3 times.
- Follow the LED indicators to connect additional smoke alarms.
- Test the connected smoke alarms by pressing the test button.
Resetting Connections
- Disconnect the smoke alarm to reset it.
- Press and hold the test button while activating the smoke alarm again.
- Follow the LED indications to clear the network connection.
FAQ
-
Q: How often should I replace the smoke alarm?
A: The smoke alarm should be replaced every 10 years after activation. -
Q: Can I install the smoke alarm in a leisure accommodation vehicle?
A: It is not specified for installation in leisure accommodation vehicles. Please refer to local regulations.
SMOKE DETECTOR
WIRELESS CONNECTED
Thank you for purchasing our smoke alarm!
Please read these instructions carefully and store them in a safe place where
you can access them easily.
Product description and intended use
This is a smoke alarm with radio link function with an optical sensor for
installation in residential buildings, apartments and rooms with residential-
like use. Smoke alarms are designed to provide an early warning of fire smoke
and fires to persons present, so that these persons can react appropriately to
the hazardous event. Always consult local regulations for smoke alarms.
Product specifications
- Detection method: Optical
- Power supply: Sealed battery 3V DC
- Battery lifetime: 10 years
- Alarm volume : ≥ 85 dB (A) at 3 meters
- Monitored area : 40 m²
- Operating temperature : 0 °C – 45 °C
- Operating humidity: < 93 %
- Date of replacement: See product label
- Individual alarm indicator: Yes
- Alarm silence facility: Yes | Hush time: 5-15 minutes
- Low battery warning: Yes
- Low battery silence facility: Yes | Hush time: 10 hours
- Installation in leisure accommodation vehicles: Yes
- Mounting location: Ceiling or wall
- Interconnectable: Yes | max. 40 devices
- Wireless frequency: 868.3 MHz
- Wireless distance : 35 meters (100 meters open space)
Warnings
- To prevent injury, this apparatus must be securely attached to the ceiling/wall in accordance with the installation instructions.
- Batteries should not be exposed to excessive heat such as sunshine, fire or the like.
- Do not paint or cover the smoke alarm.
Where to install a smoke alarm
- Smoke alarms must be installed in such a way that they can be reached unhindered by the fire smoke so that fires can be reliably detected during the development phase.
- Install at least in sleeping areas (especially children’s rooms).
- Install at least in escape rooms.
- In the middle of the ceiling of a room.
- At least 50 cm away from the wall and other objects.
- Maximum installation height of 6 meter.
- If ceiling installation is not possible, the smoke alarm can be installed on the wall. The distance to the ceiling should be between 30 and 50 centimeters.
Where to install a smoke alarm in rooms with special geometries
- Corridors with a maximum width of 3m: Max. 15m between 2 smoke alarms. Max. 7,5m to the front side of the gallery and smoke alarms at edges/crossings of corridors.
- Rooms with sloping ceilings:
- If the ceiling inclination is > 20° to the horizontal: Smoke alarms must be installed at least 0.5 m and at most 1 m from ceiling top.
- Partial roof slopes: If the flat ceiling is ≤ 1m wide, consider as ceiling inclination is of > 20°. If the flat ceiling is >1m wide, consider as flat ceiling.
- Rooms with subdivided ceilings:
- Height of the subdivisions is ≤ 0.2 m: Beams without consideration; smoke alarm may be installed on the beams as well as on ceiling.
- Height of subdivisions is > 0.2 m and area of ceiling panels > 36 m²: Smoke alarm should be installed in each ceiling panel.
- Height of subdivisions > 0.2 m and area of ceiling panels ≤ 36 m²: Individual ceiling without consideration.
Where not to install a smoke alarm
- In an environment with a high risk of draught (e.g., close to air conditioning, fans and ventilation outlets). The movement of air can impair the penetration of fire smoke into the smoke alarm.
- Areas where combustions regularly occur, such as kitchens.
- Areas with high humidity such as bathrooms, or close to devices such as dish washers or washing machines.
Activation (view page 1_A-B)
- Before using the smoke detector, it is important to activate and test it.
- Use a screwdriver to push the activation switch to “B = ON”, on the front side a red LED will light up very briefly.
- Test the correct activation of your smoke detector by pressing the test button for a few seconds, you will hear the test signal, the smoke detector is functioning as it should.
- Then return the switch to the “A” position.
- The smoke detector is automatically reactivated by placing it on the mounting plate and turning it to the left, 2 plastic hooks on the mounting plate set the switch to the “B = ON” position. Warning
- Replace 10 years after activation:
- If the test signal is not heard, the smoke detector must not be used!
Connect your smoke alarms (view page 1)
- Choose one smoke alarm as the master smoke alarm.
- Turn your master smoke alarm into the connect mode by quickly pressing the test button 3 times.
- The red LED (frontside) will light up, followed by the blue LED (backside). This indicates that the smoke alarm turned into the connect mode in which it remains for 30 seconds.
- Turn the next smoke alarm into the learn mode by quickly pressing the test button 3 times.
- The red LED (frontside) will light up, followed by the green LED (backside). This indicates that the smoke alarms are connected to each other.
- Repeat step 1 to 5 for connecting more smoke alarms. Make sure that you always use the same master smoke alarm!
- Test if your smoke alarm were connected successfully by pressing the test button of a random device until it beeps. The red LED of all connected devices will flash twice per second for five minutes. Please note! The paired detectors will not sound alarm during the test.
Reset connection
- Place the mounting plate on the desired installation location and mark where the holes should be drilled.
- Drill two holes with a diameter of 5 millimeters.
- Push the plastic plugs into the holes.
- Insert the screws into the mounting plate and tighten them firmly into the plugs.
- Place the smoke alarm on the mounting bracket and secure it by turning it clockwise.
- Test the correct operation of your smoke alarm by pressing the test button. If no sound is generated, the smoke alarm is not functioning properly and should not be used!
Alarm silence facility
When the smoke alarm has detected smoke and turns into the alarm mode, you can
mute the alarm for a minimum of 5 minutes and a maximum 15 minutes by pressing
the test button. After that, the smoke alarm automatically resets and returns
into the normal operation mode. If there are still particles of combustion in
the air, the smoke alarm will turn into the alarm mode again. WARNING: Before
using the alarm silence facility, always identify the cause of the alarm and
make sure that the circumstances are safe.
Low battery mode
When the battery is running low, the smoke alarm will indicate this with a
repetitive beep and flash for approximately 30 days. WARNING: This smoke alarm
is equipped with a non-replaceable battery. When this warning occurs, replace
the device as soon as possible! The acoustic low battery warning signal can be
muted for ten hours by pressing the test button. The smoke alarm is still
functioning and able to detect smoke when it’s in this mode.
Fault warning mode
When the smoke alarm is not functioning properly, it will turn into the fault
warning mode. Try cleaning the smoke alarm (see paragraph maintenance) or
replace the smoke alarm!
Maintenance
- Test this smoke alarm weekly for correct operation using the test facility. If the smoke alarm functions correctly, it will generate a loud beep. Due to the loudness of the alarm, make sure that you always stand at arm’s length distance from the unit when you are testing. If the smoke alarm does not generate an acoustic signal, the smoke alarm must be replaced immediately!
- Clean the smoke alarm at least once per month to remove dirt, dust or debris. Use a vacuum cleaner with a soft brush and vacuum all sides and covers of the smoke alarm. Do not remove the top cover of the smoke alarm to clean it inside.
- Do not attempt to repair this smoke alarm. If the smoke alarm shows a damage related to its functionality, it must be replaced!
- Trouble shooting: False alarm is often caused by dust or steam.
Operating mode| Visual (red flash)| Acoustic (beep)|
Description mode
---|---|---|---
Normal| 1 x per 40 seconds| None| Device is functioning properly
Test| 1 x per second (3 x) / pause of 1,5 seconds| 1 x per second (3 x) /
pause of 1,5 seconds| Device is being tested
Alarm| 1 x per second (3 x) / pause of 1,5 seconds| 1 x per second (3 x) /
pause of 1,5 seconds| Device has detected smoke
Wireless alarm| None| 2 x per seconds| Connected device detected smoke
Alarm silence| 1 x per 8 seconds| None| Smoke alarm is muted
Low battery warning| 1 x per 40 seconds| 1 x per 40 seconds| Battery is
running low
Connected low battery warning| 1 x per 3 hours| 1 x per 3 hours| Battery of
connected device is running low
Low battery warning silence| None| None| Low battery warning is muted
Fault warning| None| 1 x per 40 seconds| Device is not functioning properly
Recycling and disposal
The WEEE symbol means that this product and batteries must be disposed
separately from other household waste. When they reach their end of life, take
them to a designated waste collection point in your area to guarantee a safe
disposal or recycling. Protect the environment, human health and natural
resources!
1116
DoP:
F Z5010R 01 22
F Z5010R
Fire Safety EN 14604:2005 + AC:2008
By affixing the CE marking on a product, the manufacturer declares that the product complies with all legal requirements for CE marking and can be sold throughout the EEA.
Service and contact
To ensure that we can provide our customers with the best possible service as
quickly as possible, we ask you to consider the following:
Go to www.elro.eu to receive a quick answer to your
question. Here you will find answers to frequently asked questions, detailed
installation videos and the most recent version of a product manual. Can’t
resolve your question using the website? Leave a question via the product page
or send an email to info@elro.eu we will help you as
soon as possible. For the warranty conditions applicable to this product,
please visit www.elro.eu