BROAN QS342BC 42 Inch Under Cabinet Range Hood Instruction Manual
- July 12, 2024
- Broan
Table of Contents
QS342BC 42 Inch Under Cabinet Range Hood
Instruction Manual
QS342BC 42 Inch Under Cabinet Range Hood
This Owner’s Manual is provided and hosted by Appliance Factory Parts.
Appliance Factory Parts
Experts in BBQ, Humidifier. & Appliance Parts
1-800-955-7075
Shop genuine replacement parts for BROAN
QS342BC
Find Your BROAN HVAC Parts – Select From 1309
Models
ALLURE® QS3 SERIES RANGE HOOD
READ AND SAVE THESE INSTRUCTIONS
FOR DOMESTIC COOKING ONLY
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
-
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
-
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
-
Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
-
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. -
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
-
To reduce the risk of fire or electric shock, do not use this range hood with an additional speed control device.
-
Ducted fans must always be vented to the outdoors.
-
To reduce the risk of fire, use only metal ductwork.
-
Use with approved cord-connection kit only.
-
This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
- Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
- Always turn hood ON when cooking at high heat or when cooking flaming foods.
- Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
- Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
- SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
- NEVER PICK UP A FLAMING PAN — You may be burned.
- DO NOT USE WATER, including wet dishcloths or towels – violent steam explosion will result.
- Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
- Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
- For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
- To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
- For best capture of cooking impurities, your range hood should be mounted so that the top of the hood is 24-30” above the cooking surface.
- Please read specification label on product for further information and requirements.
Installer: Leave this manual with the homeowner.
Homeowner: Operating and Cleaning information on page 6.
NOTE If hood is to be installed Non-Ducted: Purchase a set of (2) non-
ducted filters from your local distributor or retailer and attach them to the
aluminum mesh filters.
TABLE OF CONTENTS
This manual is divided into sections as follows:
“PREPARE HOOD LOCATION”
Run ductwork from roof or wall cap, and electrical wiring from service panel –
to installation location
“PREPARE THE HOOD”
Get your hood ready for installation
“CONNECT WIRING”
Make electrical wiring connections to hood
“INSTALL HOOD”
Secure hood to cabinet and ductwork – install bulbs and filters
“OPERATION”
How to use the hood controls
“CLEANING”
Keep your hood in top working condition
“SERVICE PARTS”
Part numbers and exploded view of hood components
“WARRANTY”
One-year limited warranty and how to contact us
PREPARE HOOD LOCATION
- Determine whether hood will discharge vertically (3¼” x 10” or 7” Round), or horizontally (3¼” x 10” only). For vertical or horizontal discharge, run ductwork between the hood location and a roof cap or wall cap. For best results, use a minimum number of transitons and elbows.
- Use diagrams, below, for proper placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole. PREPARE HOOD LOCATION
- Run house wiring between service panel and hood location.
PREPARE THE HOOD
-
Remove 7” Round Duct Plate from top of hood. Set duct plate aside – with mounting screws.
-
Remove tape holding Filters in place. Pull down on filter tabs or finger holes and lift filters out. Set filters aside.
PREPARE THE HOOD -
Remove Teflon -coated bottom cover from hood. Set cover and mounting screws aside.
Teflon is a registered trademark of DuPont. -
Remove Damper/Duct Connector from inside the hood. Set connector aside – with mounting screws and parts bag.
-
Remove either top or back wiring knockout and install approved Electrical Cable Clamp. Non-Ducted Installation – Skip to Step 15.
The following Steps (6 thru 14) are for DUCTED INSTALLATION ONLY. -
Remove Light Panel – held in place with (3) #8 screws and (2) #8 screws. Disconnect light assembly wire harness (white connector).
PREPARE THE HOOD
-
Remove Air Chute – held in place with one (1) screw.
NOTE: Be careful not to disconnect any wires. -
Remove Baffle from air chute.
-
Rotate baffle. Reinsert baffle into air chute (as shown) so that baffle tabs fit all the way into slots in air chute. An audible “click” will be heard when fully installed. This will close off the air flow through the non-ducted slots on top of hood.
-
Re-install air chute, re-connect wire harness, and replace light panel.
NOTE: Be careful not to trap wires between support fin and light panel.
PREPARE THE HOOD -
Remove appropriate Duct Knockout(s) from top or back of hood.
-
Horizontal Discharge Only: Remove the Plate in front of the horizontal discharge knockout. Cut the Ties, lift plate out, and discard plate. DO NOT REMOVE the Metal Strip held in place with two Screws.
-
3¼” x 10” Ducted Discharge Only: Remove Tape from damper flap and attach Damper/Duct Connector over knockout opening with screws removed in Step 4 under “PREPARE THE HOOD”. Make sure damper Pivot is nearest to Top/Back Edge of hood.
-
7” Round Ducted Discharge Only: Re-install 7” Round Duct Plate removed in Step #1 under “PREPARE THE HOOD”. Install a 7” round damper (purchase separately). Damper flap must open freely in direction of airflow (away from range hood).
NOTE
To accomodate off-center ductwork, the Damper/Duct Connector can be installed up to 1-inch on either side of hood center or the 7” Round Duct Plate can be installed up to ½” on either side of hood center. In extreme off- center installations, one end of the duct connector may need to be trimmed to clear the electrical cable clamp. -
Non-Ducted Installations Only: Require a Performance Ring to be attached to the blower wheel. To install ring:
1. Remove the Blower Wheel by rocking it side to side and applying a slight force to pull wheel from motor. Remove Retaining Ring if necessary.
2. Slide the ring onto the Small Diameter End of the wheel and down to the Stop Edge of the wheel.
3. Reassemble wheel to motor. Make sure Tab on wheel fits into one of the Motor Slots.
4. Push wheel down until it is locked in place.
5. Check that wheel is properly positioned as shown. Press Sections into place if necessary. Make sure wheel turns freely.
CONNECT WIRING
WARNING: To reduce the risk of electric shock, make sure power is switched off at the service panel. Lock or tag service panel to prevent power from being switched on accidentally.
- Connect House Wiring (120 VAC) to hood. Use a piece of Cardboard to protect the cooktop, if necessary.
- Connect house black to hood black wire, house white to hood white wire, and house ground under Green Ground Screw. Securely tighten cable clamp onto house wiring.
INSTALL HOOD
-
Hang hood from (4) Mounting Screws. Slide hood towards wall until mounting screws are engaged in narrow end of (4) Keyholes. Tighten mounting screws securely. A long screwdriver works best.
-
Replace bottom cover.
-
Connect ductwork to hood. Use Duct Tape to make joints secure and air tight.
-
Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) R16, 40 W Maximum Incandescent Bulbs. Purchase bulbs separately.
CAUTION: Bulbs may be hot! Refer to bulb packaging for further information. -
Replace filters, turn on power at service panel, and test for proper operation.
NON-DUCTED FILTERS
If hood is to be installed Non-Ducted:
Purchase a set of (2) Non-Ducted Filters from your local distributor or
retailer and attach them to the aluminum mesh filters.
NOTE: For models that are installed in the non-ducted mode, the most effective
operation is achieved at speeds 1 and 2. These speeds provide the most
efficient and quiet operation during cooking, while maximizing the benefits of
the recirculating filtration system.
OPERATION
Fan: 4 push button switches. Push any button to select one of the four fan
speeds. Press another button to change fan speed. Push the same button to turn
fan off. A light above each fan button indicates the fan speed.
Lights: Press “on/off ” button and lights will come on at their previ- ous
light level. Press button again to turn lights off. To increase light level,
press the “+” button. To reduce light level, press the “-” button. There are 3
light levels to select.
Delay Off: While fan is running, press the “delay” button to allow the fan to
run for 10 minutes and then turn itself off.
Filter Change Indicator: The light above “filter” will come on when it is time
to clean your grease filters or check your non-ducted filters. After replacing
the cleaned, or new filters, press the “filter” button to turn off the
indicator light.
Heat Sentry System: Your range hood is equipped with an advanced Heat Sentry
system.
The advanced Heat Sentry system monitors temperature and automatically adjust
the fan to the appropriate setting.
- If the fan is on, the Heat Sentry system will increase the fan setting when the temperature is elevated. If the temperature continues to rise, the Heat Sentry system will continue to increase the fan setting until the temperature is stabilized or reduced. The flashing light above the fan button shows the Heat Sentry system fan setting. Once the temperature has reduced, the Heat Sentry system will change the fan to the original setting.
- If the fan is on or off, the Heat Sentry system will automatically turn the
fan on at its highest speed when the temperature is above normal. When the
Heat Sentry system is on, the light above the fan button B (Boost) will flash
on and off. After the temperature has lowered to normal, the fan will change
to the setting prior to the Heat Sentry turning on.
Fuse: The hood control contains a fuse to protect it from power surges. If the fuse has opened (blown), the green fan-level indicators will operate properly when the fan buttons/switches are pressed – but the fan and lights will not turn on.
The fuse is a 5 x 20 mm, 10 Amp, Fast-Acting, 125V (min.). Common manufacturer and part numbers are: Littlefuse, 217010; Bussmann, GMA10A; Wickmann, 1942100. Radio Shack, Digikey (1-800-3444539), and most electronic supply stores have
them in stock.
To replace the fuse:
- Disconnect power at service entrance.
- Remove filters, bottom panel, light wire harness, and air chute.
- Remove and inspect fuse. If it is not open (blown), additional diagnostics need to be done.
SERVICE PARTS
KEY NO. | PART NO. | DESCRIPTION |
---|---|---|
1 | R680508 | 7” Round Duct Plate (includes hardware) |
2 | R740013 | Damper/Duct Connector (includes hardware) |
3 | R602017 | Screw, #8-18 x ¼ Hex* (2 in package) |
4 | R334126 | Motor Capacitor (includes wire nuts & hardware) |
5 | R501031 | Isolation Transformer |
6 | R627505 | Nameplate, White |
R627506 | Nameplate, Almond | |
R627507 | Nameplate, Black | |
R627529 | Nameplate, Biscuit | |
7 | R169011 | Control Panel, White (includes Key No. 6 & hardware) |
R169012 | Control Panel, Almond (includes Key No. 6 & hardware) | |
R169013 | Control Panel, Black (includes Key No. 6 & hardware) | |
R169014 | Control Panel, Biscuit (includes Key No. 6 & hardware) | |
8 | R601535 | Screw for Plastic, #6 x ½ Flat Hd. (3 in package) |
9 | R602534 | Screw, #8-18 x 3/8 (2 in package) |
10 | R602533 | Ground Screw |
11 | R680505 | Scroll Cover, Outlet (includes hardware) |
12 | R680507 | Scroll Cover, Front (includes hardware) |
13 | R111653 | Control Assembly (includes Key Nos. 6, 7 & hardware) |
14 | R401647 | Air Chute Assembly (includes Key No. 15 & hardware) |
15 | R401646 | Baffle |
16 | R601536 | Screw, Metric M4 x 6mm (4 in package) |
17 | R651973 | Motor Plate (Includes Key No. 18) |
18 | R169009 | Motor Plate Mounting Kit (3 of each part) |
19 | R520133 | Motor (includes Key No. 16) |
20 | R531068 | Blower Wheel (Includes Key No. 21) |
21 | R607215 | Retaining Ring |
22 | R111630 | Lamp Socket Assembly |
23 | R7201731 | Light Panel, 30 in. White |
R7201751 | Light Panel, 36 in. White | |
R7201771 | Light Panel, 42 in. White | |
R7201732 | Light Panel, 30 in. Almond | |
R7201752 | Light Panel, 36 in. Almond | |
R7201772 | Light Panel, 42 in. Almond | |
R7201734 | Light Panel, 30 in. Black | |
R7201754 | Light Panel, 36 in. Black | |
R7201774 | Light Panel, 42 in. Black | |
R7201735 | Light Panel, 30 in. Biscuit | |
R7201755 | Light Panel, 36 in. Biscuit | |
R7201775 | Light Panel, 42 in. Biscuit | |
R720174 | Light Panel, 30 in. Stainless | |
R720176 | Light Panel, 36 in. Stainless | |
R720178 | Light Panel, 42 in. Stainless | |
24 | R607660 | Hole Plug (1 req.) |
25 | * | Pop Rivet, .125D (3 req.) |
26 | R169016 | Filter Spring Kit |
27 | R680512 | Bottom Cover, 30 in. (includes Key Nos. 9, 25, & 26) |
R680521 | Bottom Cover, 36 in. (includes Key Nos. 9, 25, & 26) | |
R680528 | Bottom Cover, 42 in. (includes Key Nos. 9, 25, & 26) | |
28 | R501035 | Autotransformer (includes hardware) |
29 | 99010305 | Aluminum Mesh Filter, 30 in. (2 in package) |
99010306 | Aluminum Mesh Filter, 36 in. (2 in package) | |
99010307 | Aluminum Mesh Filter, 42 in. (2 in package) | |
30 | R730111 | Non-Ducted Blower Wheel Assembly |
(includes Key Nos. 20 & 21)
| 99010308| Non-ducted Filter Kit, 30 in.
| 99010309| Non-ducted Filter Kit, 36 in.
| 99010310| Non-ducted Filter Kit, 42 in.
| R111668| Wire Harness
**| R564074| Control Fuse, 10-Amp
Order replacement parts by PART NO. – not by KEY NO.
- Standard hardware – may be purchased locally.
** Not illustrated – purchase separately.
WARRANTY
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for a
period of one year from the date of original purchase. THERE ARE NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this
one-year period, Broan-NuTone will, at its option, repair or replace, without
charge, any product or part which is found to be defective under normal use
and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This
warranty does not cover (a) normal maintenance and service or (b) any products
or parts which have been subject to misuse, negligence, accident, improper
maintenance or repair (other than by Broan-NuTone), faulty installation or
installation contrary to recommended installation instructions.
The duration of an implied warranty is limited to the one-year period as
specified for the express warranty. Some states do not allow limitation on how
long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION,
SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-
NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states
do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the
address or telephone number below, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence of
the original purchase date.
Broan-NuTone LLC., 926 West State Street, Hartford, WI 53027
(1-800-637-1453)
References
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Broan HVAC Parts - Select From 1309 Models
Read User Manual Online (PDF format)