MEAN WELL EPP-120S Series 120W 3×2 Green Open Frame Power Supply Owner’s Manual
- July 3, 2024
- MEAN WELL
Table of Contents
120W 3″×2″ Green Open Frame Power Supply
EPP-120S series
EPP-120S Series 120W 3×2 Green Open Frame Power Supply
https://www.meanwell.com/Upload/PDF/PCB_EN.pdf
■ Features
- 3″×2″ Compact Size
- 120W convection,150W peak (10sec.)
- EMI for both Class I & Class II configuration
- -30~+85℃ wide range operating temperature
- No load power consumption<0.3W
- High efficiency up to 94%
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Operating altitude up to 5000 meters (Note.5)
- 3 years warranty
■ Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
■ GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
■ Description
EPP-120S is a 120W highly reliable green PCB type power supply with a high power density on the 3″ by 2″ footprint. It accepts 80~264VAC input and offers various output voltages between 12V and 48V. The working efficiency is up to 94% and the extremely low no load power consumption is down below 0.3W.EPP- 120S is able to be used for both Class (with FG) and Class (no FG) system design. EPP-120S has the complete protection functions; it is complied with the international safety regulations such as TUV BS EN/EN62368-1, BS EN/EN60335-1, UL62368-1 and IEC62368-1. EPP-120S series serves as a high price-to-performance power supply solution for various industrial applications.
■ Model Encoding
SPECIFICATION
NOTE
- All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25 of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 μ F & 47 μ F parallel capacitor.
- Tolerance: includes set up tolerance, line regulation, and load regulation.
- Derating may be needed under low input voltages. Please check the derating curve for more details.
- The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitudes higher than 2000m(6500ft).
- The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
◼ Block Diagram
◼ Derating Curve
◼ Output Derating VS Input Voltage
◼ Mechanical Specification
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | AC/L | JST VHR or equivalent | JST SVH-21T-P1.1 or equivalent |
2 | No Pin | ||
3 | AC/N |
DC Output Connector (CN100) : JST B4P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1,2 | +V | JST VHR or equivalent | JST SVH-21T-P1.1 or equivalent |
3,4 | -V |
1. HS1 must have safety isolation distance with system case.
※ Note :
- EPP-120S model delivers EMI Class B for both conducted emission and radiated emission for the power supply, when configured into Class I (with FG) system.
- EPP-120S model delivers EMI Class B conducted emission and Class A radiated emission with King Core K5B RC (12157) in output cable for the power supply when configured into Class II (no FG) system.
◼ Installation Manual
Please refer to : http://www.meanwell.com/manual.html
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>