Safety Information

  • All instructions, warning and caution statements that accompany this equipment must be strictly followed at all times to ensure its safe use.

  • Observe all warning and caution symbols that are fixed to this equipment.

  • This electrical equipment is designed with the utmost care for the safety of those who install and use it.

  • However, when using this device, basic safety precautions should always be followed to reduce the risk of fire and injury to persons, and the dangers of electric shock and static electricity.

  • Do not cover the device or block the airflow to the device with any other objects.

  • This product was qualified under test conditions that included the use of the supplied cables between system components.

  • To be in compliance with regulations, the user must use the cables supplied with the unit and install them properly.

  • This includes the power adapter that is provided. Place the unit to allow for easy access when disconnecting the power adapter from the mains wall outlet. Operate this product only with the type of power source indicated on the marking label.

  • If you are not sure of the type of power supplied to your home, consult your dealer or local electricity company.

  • Do not use this product near water, for example a swimming pool or a bathroom.

  • Keep the device away from excessive heat and humidity and keep the device free from vibration and dust.

  • Wipe the unit with a clean, dry cloth. Never use cleaning fluid or similar chemicals.

  • Do not spray cleaners directly on the unit or use forced air to remove dust.

  • Avoid installing or using this product during an electrical storm.

  • There may be remote risk of electric shock from lightning.

  • During a lightning storm for added protection please unplug it from the wall outlet and disconnect all cables.

  • This will prevent damage due to lightning and power surges. For safety reasons, only
    authorized service technicians should open the device. If the device is opened the warranty will become void.

  • The device may affect medical equipment and so please take account of any technical restrictions with this equipment.

  • This device, like other radio devices, emits radio frequency electromagnetic energy but operates within the guidelines found in radio frequency safety standards and recommendations.

  • It is recommended that the minimum operating distance from the installed Access Point to persons is 53cm.

General Hazard Statement
Safety notes are marked with symbols. Ignoring the safety notes may lead to personal injury, damage to the instrument and malfunctions.
Signal Words identify the hazard severity level as follow:

Signal word Meaning
DANGER Indicates an extremely hazardous situation which, if not avoided, will

result in death or serious injury.
WARNING| Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION| Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE| Indicates a hazardous situation not related to personal injury.

Accessories

SERCOMM-SCO4255P-BC-A10-Englewood-HGO-Outdoor-
fig-9

Introduction
Englewood HGO is an outdoor Small Cell, self-configuring small cell device that will be used to CBRS network and LTE coverage at the customer premises.

Package Contents

Package will include the following items:

  • 1 x Englewood HGO Device
  • 1 x AD/DC Power Supply Adapter and bracket
  • 1 x Device bracket
  • 2 x RJ45 waterproof casing
  • 1 x Grounding cable
    If any of the above items are damaged or missing, please contact your dealer immediately.

Key Feature

  • Designed for outdoor Small Office Retention
  • LTE Small Cell Access up to 64 LTE active users
  • 4T4R LTE with internal 9.8dBi antenna
  • Support 4G TD-LTE Band 48 for Small Cell access
  • Support Ethernet for LTE Backhaul
  • Internal GPS antenna

Interface I/O

SERCOMM-SCO4255P-BC-A10-Englewood-HGO-Outdoor-
fig-1

Power Input DC 12V/2.5A
LAN Lan port input for console configuration
WAN Wan port for backhaul connect and support PoE+ input

Initial Installation

  • This mobile broadband base station RF device will provide high quality wireless broadband network coverage It has an Ethernet port and WAN Internet connection.Follow the steps below to install it.
  • Device is outdoor Access Point and must need special trained professional in configuring and installing the product.

Installation

SERCOMM-SCO4255P-BC-A10-Englewood-HGO-Outdoor-
fig-2

  • Step1:
    4 screws are attached to the lock M5*14, fix the power bracket on the bottom shellSERCOMM-SCO4255P-BC-A10-Englewood-HGO-Outdoor-
fig-3

  • Step2:
    Place the power adapter On the power bracket
    (The connector of the Power adapter corresponds with the power port )

  • Step3:
    Assemble fixing bracket, lock with M8*16 screws

  • Step4:
    Assemble the base station bracket, and lock the bolts and screws after adjusting the Angle required by the device.

  • Step5:
    Install the RJ45 cableSERCOMM-SCO4255P-BC-A10-Englewood-HGO-Outdoor-
fig-7

  • Step6
    Instal1 the ground cable

Specifications

General Specification

Connectivity| –    4x Internal LTE Antennas

–    2x Ethernet connection

---|---
Power Supply| External Power Adapter:

Input: AC100~240V, 50Hz/60Hz, 1.2A Max.

Output: 12 Vdc, 2.5A

Operating Requirement| Operating Temp. -40ºC to 55ºC Storage Temp. -40ºC to 70ºC

Operating Humidity 5% to 90% Non-Condensing

Storage Humidity 5% to 95% Non-Condensing

Housing| 410mmx286mmx115 mm

RF Characteristics

SERCOMM-SCO4255P-BC-A10-Englewood-HGO-Outdoor-fig-10

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Operations in the 5.15-5.25GHz band are restricted to indoor usage only.

Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 53cm between the radiator & your body.
Note: The country code selection is for non-US model only and is not available to all US model. Per FCC regulation, all WiFi product marketed in US must fixed to US operation channels only.