SERCOMM SCE4103C-BV Wireless Adapter User Manual

June 5, 2024
Sercomm

Bridgewood Small Cell
Model: SCE4103C-BV
Quick Installation Guide

Manufacture By: Sercomm Corporation
8F, No. 3-1, YuanQu Street, Nankang, Taipei 115, Taiwan, R.O.C.

Chapter 1

Introduction

Bridgewood is an indoor, self-configuring small cell device that will be used to public network and LTE coverage at the customer premises.

Package Contents

The package will include the following items:
1 x Bridgewood SCE4103C-BV Device
1 x AC/DC Power Supply Adapter
If any of the above items are damaged or missing, please contact your dealer immediately.

Key Feature

  • Designed for indoor/Small Office Retention
  • LTE Femto Cell Access up to 16
  • LTE active users 2T2R LTE with OMNI antenna for easy installation
  • Support 4G FD-LTE Band 66/4, 13 for Femto Cell access
  • Support Ethernet for LTE Backhaul
  • 1 x LED status display and Info Button
  • Internal LTE antennas

LEDs
Bridgewood has 1 LED indicators. Table below describes the definition of LED:

Front & Rear Panel

Front Panel

Interface Panel

Power Input: 12 Vdc, 2A, Power Jack to Power Adaptor
PPS External 1PPS signal input connector
X2 LAN port input or 5G DUT configuration
WAN WAN port for backhaul connect
Reset Factory reset button

Chapter 2

Initial Installation

SCE4103C-BV is designed for Plug-n-Play(PnP) and self-configure which not require any software installation to use. When device power on the device, it will start to connect to backhaul eNB and begin the device Plug PnP and provision processes. The PnP and provision process will take approximate 6~7 min. to bring up and activate the device service.

  1. Small cell device provides mobile network SONSelf-Organizing Network, it is plug& play which can auto-configuration to install.
  2. Install the Ethernet cable into device WAN port.
  3. Another Ethernet cable connector connects to router.
  4. Install the Power Adapter DC port into device power jack.
  5. When LED steady to flash to green, the device can be used. If the LED indicates different the LED status, please call your agent.

Chapter 3

Specifications

General Specification

Connectivity| – 3 x Internal Antennas
– Ethernet wired connection
---|---
Power Supply| External Power Adapter:
Input: AC100-240V, 50Hz/60Hz, 0.7A Max. Output: 12 Vdc, 2A
Operating Requirement| Operating Temp. 0°C to 40°C
Storage Temp. -5°C to 45°C
Operating Humidity 5% to 90% Non-Condensing Storage Humidity 5% to 95% Non- Condensing
Reset button| Reset & Info Button
LED| 1 LED for Status.
Housing| 220rrun(W)x 220mm(D)x 63mm(H)

RF Characteristics

LTE Access RF| Transceiver
Working LTE frequency
Technology
Tx Power(B48)
Listening bands
Bandwidth| QCA FTR8930
B66/4, 13
2T2R MIMO,
17dBm Max per chain (Conduced)
B66/4, 13 5, 10, 15, 20 Mhz
---|---|---

Regulatory Requirements

FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution : Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Operations in the 777-787, 1710-1780 and 2110- 2200 MHz band are restricted to indoor usage only.

Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Note: The country code selection is for non-US model only and is not available to all US model. Per FCC regulation, all WiFi product marketed in US must fixed to US operation channels only.

Safety Information

All instructions, warning, and caution statements that accompany this equipment must be strictly followed at all times to ensure its safe use. Observe all warning and caution symbols that are fixed to this equipment. This electrical equipment is designed with the utmost care for the safety of those who install and use it. However, when using this device, basic safety precautions should always be followed to reduce the risk of fire and injury to persons, and the dangers of electric shock and static electricity. Do not cover the device or block the airflow to the device with any other objects. This product was qualified under test conditions that included the use of the supplied cables between system components. To be in compliance with regulations, the user must use the cables supplied with the unit and install them properly. This includes the power adapter that is provided. Place the unit to allow for easy access when disconnecting the power adapter from the mains wall outlet. Operate this product only with the type of power source indicated on the marking label. If you are not sure of the type of power supplied to your home, consult your dealer or local electricity company. Do not use this product near water, for example, a swimming pool or a bathroom. Keep the device away from excessive heat and humidity and keep the device free from vibration and dust. Wipe the unit with a clean, dry cloth. Never use cleaning fluid or similar chemicals. Do not spray cleaners directly on the unit or use forced air to remove dust. Avoid installing or using this product during an electrical storm. There may be remote risk of electric shock from lightning. During a lightning storm for added protection please unplug it from the wall outlet and disconnect all cables. This will prevent damage due to lightning and power surges. For safety reasons, only authorized service technicians should open the device. If the device is opened the warranty will become void. The device may affect medical equipment and so please take account of any technology restrictions with this equipment. This device, like other radio devices, emits radio frequency electromagnetic energy but operates within the guidelines found in radio frequency safety standards and recommendations. It is recommended that the minimum operating distance from the installed Access Point to persons is 25cm.

General Hazard Statement
Safety notes are marked with symbols. Ignoring the safety notes may lead to personal injury, damage to the instrument and malfunctions.

Signal Words identify the hazard severity level as follow:

Signal word Meaning
DANGER Indicates an extremely hazardous situation which, if not avoided, will

result in death or serious injury.
WARNING| Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION| Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE| Indicates a hazardous situation not related to personal injury.

WARNING
Electric-shock hazard
Contact with energized parts can cause serious injury.

At least one other trained person must be in attendance, who can immediately and safely disconnect the system if necessary.
This second person must be trained in first aid for emergency purposes

WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
Practices and the safety warnings may lead to bodily injury and property damage.
For this reason, only trained and qualified personnel (electrical workers as defined in
IEC 60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No. 10) may install or service the installation.

WARNING
Electric-shock hazard
Risk of electric shock
a) Do not open the AC adaptor housing. Make sure that the AC adapter does ot come in contact with liquids.
b) Use Only the 3-pin power cord with equipment grounding conductor which was supplied with your instrument and only on 3-pin grounded outlet must be used.

NOTICE
Flammable-material hazard

The Cooling vents at the right & left of the enclosure can become obstructed, preventing ventilation of the enclosure.
Make sure that the air vent is not obstructed and remains clear at all times.

Device Surface Cleaning

You may clean the device case using a cloth dampened with mild liquid detergent (such as Dawn) and water.

WARNING
Electric-shock hazard

Always unplug/disconnect power before apply any cleaning to Device.
Warning Do not submerse the Device or its accessories in water or allow water to enter into the case; this may lead to electrical shock and/or damage

Accessories

Item Description P/N
AC/DC Adapter (without power core) AC100 240V~0.7A, 50Hz/60Hz auto
switching, 12 V DC, 2A 910202125LD

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>