  1. Fixture weight ±2 lbs: Peso±21b:
  2. Poids fixe ±2 lbs:v
  3. 10.71bs (4.8kg)

Hardware Service Kit

Hunter-19790-Gatz-Pendant-Fan-Instruction-Manual-
fig-2

Glass

Hunter-19790-Gatz-Pendant-Fan-Instruction-Manual-
fig-3

INSTALLATION INSTRUCTIONS

  • To avoid possible electrical shock, before installing your light fixture, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location.
  • The lighting fixture must be grounded. If the ground wire for the installation site is not present, immediately STOP installation and consult a qualified electrician. immediately STOP installation and consult a qualified electrician.

All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring or in doubt consult a qualified electrician.

Here are the  tools you’ll  need to complete your installation:

PREPARING FOR INSTALLATION

Carefully remove all contents from the carton. Shut off the power at the circuit breaker and completely remove the
old fixture from the ceiling, including the old mounting bracket. Remove the new mounting bracket assembly from the bag. Remove cap nuts (H) from mounting screws (B). Place the mounting plate (A) over the junction box so that mounting screws (B) and nuts (C) extend out away from the ceiling. Adjust the position of mounting screws (B) so
that mounting screws (B) can be exposed 5-6 mm after passing through the canopy (F) to properly fit the cap nuts. Depending on the placement of your junction box the position of mounting screws (B) may need to be adjusted to allow the canopy to be flush with the ceiling. Mounting screws (B) can be adjusted by loosening nuts (C) and loosening or tightening mounting screws (B). Once the ideal position of mounting screws (B) has been confirmed, tighten nuts (C) on mounting screws (B) on the front of the mounting plate to ensure that mounting screws (B) are secure. Pull the house wires through the center of the mounting plate (A). Secure the mounting plate (A) to the junction box by tightening the screws (D).

ASSEMBLING THE FIXTURE

There are 4 12-inch rods (K), and 1 6-inch rod (I) included for each fixture. Determine the correct number of rods needed for proper hanging height. To lengthen the fixture, add additional rods. To shorten the fixture, trim the wires to the desired length. Leave at least 8 to 10 inches of wire in addition to the desired length and slide any excess rods off the fixture’s wiring to discard. Keep in mind that you must use at least one rod to hang the fixture. Thread the wires through the rods and pull the wires until taut before connecting the rods. All threads should be engaged but do not overtighten (some manual straightening of the downloads may be required). Screw the rod onto the threaded post (L) of the fixture. Pull the fixture wires through the top of the canopy. Screw the top rod to hang straight (G) of canopy (F).

CONNECTING THE WIRES

Have a helper support the fixture’s weight while completing the wiring. Attach the fixture’s wires to the power supply wires from the junction box. Connect black to black (live); white to white (neutral); grounding to grounding (green or copper). Twist the ends of the wire pairs together. Then, twist on a wire connector. Make sure all twists are in the same direction. Loop the fixture’s ground wire around the grounding screw (E) and tighten. If there is no ground wire (green or copper) from the junction box, contact a qualified electrician.

FINISHING THE INSTALLATION

To install on a sloped ceiling, make sure that the notched side of hang straight (G) faces away from the peak of the ceiling (twist into place if needed). Raise canopy (F) to mounting plate (A) and position mounting screws (B) so that they protrude through the openings of the canopy (F). Secure canopy (F) in place with cap nuts (H). Once attached to the junction box, grasp the rods firmly with both hands and gently pull toward the notch until the fixture is at the desired angle. Secure glass (N) onto the socket (M) using the socket ring (O). Install a light bulb (not included) in accordance with the fixture’s specifications. Do not exceed the recommended wattage. Your installation is now complete. Turn on the power and test the fixture.

CLEANING TIPS

Treat the fixture gently! Regular cleaning will reduce the need for deep cleaning. For regular cleaning, turn off the light and wipe down the fixture with a clean lint-free cotton or microfiber cloth. Never spray cleaner directly onto the fixture.

Notice

In order to use a 12in rod by itself you must first remove the post from the 6in rod and install it on one of the ends of the 12in rod.

Hunter Pro Tip

Twist or tape wire ends together to make it easier to pass them through the downloads. Threaded posts may also be removed for easier wire access. Twist or tape wire ends together to make it easier to pass them through the downloads. Threaded post may also be removed for easier wire access. Twist or tape wire ends together to make it easier to pass them through the downloads. Threaded posts may also be removed for easier wire access.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals