DESCRIPTION
The NiteTime PlusTM provides automated, timed control of lights and
small appliances. The NiteTime PlusTM plugs into a wall outlet and connects to a standard household lamp or small appliance. The low profile design fits behind furniture and offers a discreet design to fit any room décor.
Eight pre-programmed settings allow for instant, one-time setup. Programs include basic On and Off timed settings triggered by lighting conditions, as well as randomly-timed modes for creating a lived-in appearance while you are away trom home A built-in photocell automatically adjusts the timer to Daylight Savings
Time changes so no resetting is required- even after power outages. The NiteTime PlusTM also includes a photosensitivity setting for use in rooms with low or high ambient lighting. The convenient Override button allows temporary override of programming for use of a lamp or small appliance.

FEATURES

  • Eight pre-programmed On-Off time segments allow for instant setup, and one-time setup.
  • A built-in photocell senses ambient room light and automatically triggers On-Off time segments.
  • A built-in photocell automatically adjusts the timer for Daylight Savings Time changes.
  • The photosensitivity setting adjusts the timer to ambient room light levels.
  • The timer requires no resetting even after power outages.
  • The override button allows for temporary use of lamps or smal appliances.
  • Low profile design fits behind furniture and blends with room décor.
  • The timer can be used with incandescent (standard bulb), compact fluorescent (CFL), or halogen-based bulb lamps.
  • Timer can be used with small appliances under 500 watts or four Amps such as a radio or television.

LIMITATIONS/WARNINGS

  • For indoor use only
  • Not recommended for devices over 500 watts or four Amps
  • When used on a device controlled by a wall switch, the wall switch must remain on at all times for the NiteTime PlusTM to function properly.
  • When used on a lamp with a dimmer, the dimmer functionality is inoperable.

HOW TO USE THE NITE TIME PLuSM

Choose the Timer Setting
Before plugging the timer into a wall outlet, choose the desired time program using the Program dial. These instructions apply to both lamps and small electronics. Once set, the program never needs resetting for Daylight Savings Time or power outages.
If a timed program is not needed, set the Program dial to 1 Power On and use the lamp switch to turn the lamp On and Off. To revert back to a timed program, change the Program dial to one of the following settings:

2-Dusk +2hr turns power On at dusk, turns the power off 2 hours later.
3 Dusk +4hr turns power On at dusk, turns power off 4 hours later
4-Dusk +6hr turns power On at dusk, turns power off 6 hours later
5- Dusk +8hr turns power On at dusk, turns the power off 8 hours later.
6-Dusk +2hr Randomly powers On/ off for 30 minutes within each hour after dusk for 2 hours.
7-Dusk +4hr Randomly powers On/ off for 30 minutes within each hour after dusk for 4 hours.
8 Dusk +6hr Randomly powers On l off for 30 minutes within each hour after dusk for 6 hours. HUNTER-45030-NiteTime-Plus-Easy-Set-Timer-
fig-2

SET UP THE NIGHTTIME PLUSTM
Adjusting the Photosensitivity Dial

  1. Find a preferred location with the appropriate type of lamp or appliance. The ambient lighting condition is the preferred condition for the light to turn On.
  2. Turn the lamp or appliance Off.
  3. Set the Program dial to your preferred setting (see Choose the Timer Setting above).
  4. Set the Photosensitivity Dial to a Minimum.
  5. Plug the lamp or appliance into the NiteTime PlusTMHUNTER-45030-NiteTime-Plus-Easy-Set-Timer-fig-3
  6. Plug the NiteTime PlusTM into a wall outlet.
  7. Turn the lamp or appliance On.
  8. Slowly dial the Sensitivity dial from Minimum toward Maximum until the lamp or appliance powers On. Avoid casting a shadow over the NiteTime PlusT photocell.
  9. The Photocell will turn On the light or appliance according to this lighting condition. The Photosensitivity dial is now set.

Program Setup

  1. Remove the NiteTime PlusTM from the wall and Set the Program dial
    to your preferred program. (See Choose the Timer Setting, above.)

  2. Plug the NiteTime PlusTM into the wall outlet.
    The NiteTime PlusTM is now set up to control your lamp or appliance.

Override Operation

The Override button on the front of the NiteTime PlusTM lets you temporarily override the existing program and use the attached lamp or appliance without programming.
Press the Override button once to power the lamp or appliance On or Off (depending on the current program sequence). To return the NiteTime PlusTM to its programming, press the Override button one more time.
In the event, the Override button is not manually pressed to return to programming, the NiteTime PlusTM automatically reverts to
programming during the next time sequence.
The LED under the Override Button comes on when the timer output is off. The LED goes off when the timer output is on.

Hunter Fan Company
2500 Frisco Avenue
Memphis, Tennessee 38114
For other problems or questions, contact the
Hunter Fan Company Technical Support at
US 888-830-1326/ Canada 866-268-1936.
http://www.hunterfan.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Hunter User Manuals

Related Manuals