PRODUCT

IMPORTANT SAFETY DETAILS

  1. Ensure the AC/Mains power is NOT connected and cannot be unexpectedly reconnected during installation.
  2. This product must be installed by a qualified electrician in accordance with instructions provided and in compliance with recognised electrical and safety regulations relevant to the country it is being installed.
  3. This product may NOT be installed by minors or people with a mental disability.
  4. This wall light must be installed to the current edition of the IEE wiring regulations and relevant building regulations in your country.
  5. This wall light is designed for indoor and outdoor use.

INSTALLATION

HOFTRONIC-5426988-6x -Mason-Pir-With-Daylight-Sensor-Led-
Wall-Light-FIG-1 HOFTRONIC-5426988-6x -Mason-Pir-With-Daylight-
Sensor-Led-Wall-Light-FIG-2 HOFTRONIC-5426988-6x -Mason-Pir-With-Daylight-
Sensor-Led-Wall-Light-FIG-3

CHANGING THE TIMER

Decreasing the timer will keep the lamp burning for a shorter time, increasing the timer will keep the lamp burning for a longer time after the lamp will turn on.HOFTRONIC-5426988-6x -Mason-Pir-With-Daylight-Sensor-Led-Wall-Light-
FIG-4

CHANGING THE SENSOR SENSITIVITY

Decrease the twilight sensor sensitivity if you want the lamp to turn on only when it is dark, by increasing the twilight sensor sensitivity the lamp will turn on earlier, for example when it starts to get dark or when it is very cloudy.

DECREASING THE TWILIGHT SENSOR SENSITIVITYHOFTRONIC-5426988-6x -Mason-
Pir-With-Daylight-Sensor-Led-Wall-Light-FIG-5

INCREASING THE TWILIGHT SENSOR SENSITIVITYHOFTRONIC-5426988-6x -Mason-
Pir-With-Daylight-Sensor-Led-Wall-Light-FIG-6

CHANGING THE DETECTION RANGE

Decrease the detection range if you want the lamp to turn on when you are closer, increase the detection range if you want the lamp to turn on already when you are further away.HOFTRONIC-5426988-6x -Mason-Pir-With-Daylight-
Sensor-Led-Wall-Light-FIG-7

WHICH SENSORS ARE IN THIS WALL LIGHT?

In this wall light with sensor there is a PIR sensor with twilight switch and there is also the separate photocell/daylight sensor.

WHAT FUNCTIONS DO THESE SENSORS HAVE?

The PIR (Passive Infra Red) Sensor has a sensing device which continuously scans a preset operating zone on movement. The PIR sensor immediately switches the lamp on when it detects movement in that area which could be useful to illuminate a pathway, patio, garage or for security reasons around the house. While there is movement within range of the PIR sensor, the lamp will stay on illuminating the area.

THE TWILIGHT SWITCH/PHOTOCELL

On the wall light there is a second sensor control unit which switches on and off the light depending on the ambient brightness. The Twilight switch controls the light to be on or off when the ambient lighting exceeds or falls below a certain set light value in the settings. This is useful for the lamp to be on when it gets dark outside and to be off when there is enough ambient lighting.

HOW TO SETUP THE SENSOR

  1. Sens: With this option you can adjust the sensitivity of the sensor. If you want the sensor to react quickly and fast, the setting should be more to the “+”. When you want the sensor to work not immediately and slower, the setting should be more to the “-“. When the Sens setting is put on the max setting, the max distance range will be 10 meters. Put the Lux setting to daylight so you can test the detection range of the PIR sensor.
  2. Time: The time that the light stays on can be adjusted via this setting. On the lowest setting the light stays on for 10±3 seconds. On the highest setting the light stays on for 10±2 minutes.
  3. Lux: You can adjust the Lux setting from 3 Lux – 2000 Lux. With this setting you can adjust the moment when the sensor will be activated
    triggered by how much Lux is measured. When the Lux setting is on the lowest Lux Value, it means that the sensor turns on the light when there is no to little ambient light. When the Lux setting is on the highest Lux value, it means that the sensor works also during daylight. When you need the sensor to work during dusk/dawn, then the Lux setting needs to be in the middle.

WHERE TO PLACE THE SENSOR?

  • For the best functionality of the sensor and light, suggested is to place the fixture with sensor 1.5 to 2.5 meters (5ft to 8ft) above the area to be scanned.
  • Do not place the sensor directly towards the sun to prevent damage to the sensor.
  • To prevent the sensor malfunctioning, do not place the sensor closeby heat sources.
  • Place the sensor not directly across a white wall or a reflectivre surface like a swimming pool or glass windows which can trigger the sensor to go on automatically.

HOW TO ONLY USE THE TWILIGHT SWITCH/PHOTOCELL MODE WITH PIR SENSOR DEACTIVATED

When the light is turned on by the power switch, the sensor is activated into the “Warm-up” mode. This takes around 10 seconds before the sensor is activated to “Auto-mode”. To change the “Auto-mode” to only “Twilight sensor”, you have to do the following steps:

  1. Adjust LUX setting to minimum
  2. Turn the power ON for 10 seconds (this way the sensor is been activated)
  3. Turn OFF/ON/OFF/ON the power within 6 seconds

After doing these three steps, the sensor is now in photocell mode and the PIR Sensor is deactivated. When the light needs to stay on continuously, the LUX setting should be put on the sun mark. This way the light stays on.

HOW TO RESET THE TWILIGHT SWITCH SO THE PIR SENSOR IS ACTIVATED AGAIN?

Turn off the power from the lamp and keep it OFF for a minimum of 6 seconds. Then turn on the power again, this takes 1 minute to reset the sensor to normal functioning via “Auto-mode”.

INTENDED USE / APPLICATION

Product designed for the use in households and for other similar general applications.

MOUNTING

Technical changes reserved. Read the manual before mounting. Mounting should be performed by an appropriately qualified person. Any activities to be done with disconnected power supply. Exercise particular caution. Product has a protective contact/terminal. Failure to connect the protective lead may lead to electric shock. Mounting diagram: see pictures. Check for proper mechanical fastening and connection to electrical power prior to first use. The product can be connected to a supply network which meets energy quality standards as prescribed by law. To maintain the proper IP protection level, the right diameter of the power cable should be selected for the cable gland used in the product.

FUNCTIONAL CHARACTERISTICS

Product can be used indoors and outdoors.

USAGE GUIDELINES / MAINTENANCE

Any maintenance work must be performed when the power supply is cut off and the product has cooled down. Clean only with soft and dry cloths. Do not use chemical detergents. Do not cover the product. Ensure free air access. Product may heat up to a higher temperature. Product can only be supplied by rated voltage or voltage within the range provided. It’s forbidden to use the product with damaged protective cover. Product must not be used in unfavourable conditions, e.g. dust, water, moisture, vibrations, explosive air atmosphere, fumes, or chemical fumes, etc. Non-demountable product. Not suitable for independent repairs.

ENVIRONMENTAL PROTECTION

Keep your environment clean. Segregation of post-packaging waste is recommended. This labelling indicates the requirement to selectively collect waste electronic and electrical equipment. Products labelled in this way must not be disposed of in the same way as other waste under the threat of a fine. These products may be harmful to the natural environment and health, and require a special form of recycling/neutralising. Products labelled in this way should be returned to a collection facility for waste electrical and electronic goods. Information on collection centres is provided by local authorities or sellers of such goods. Used items can also be returned to the seller when new product is purchased, in quantity no larger than the purchased item of the same type. The above rules regard the EU area. In the case of other countries, regulations in force in a given country must be applied. Contacting the distributor of our products in a given area is recommended.

COMMENTS / GUIDELINES

Failure to follow these instructions may result in e.g. fire, burns, electrical shock, physical injury and other material and non-material damage. For more information about Hoftronic products visit www.hoftronic.com. Hoftronic shall not be responsible for any damage resulting from the failure to follow these instructions. Hoftronic reserves the right to make changes in the manual – the current version can be downloaded at www.hoftronic.com.

DECLARATION OF CONFORMITY

DOCUMENTATION
This product has been manufactured and supplied in compliance with all relevant regulations and directives applicable to all member states of the European Union. The product complies with all applicable regulations and rules in the country of sale.
Formal documentation such as the declaration of conformity, the safety data sheet and the product test report is available upon request.

CE DECLARATION
The product complies with the following directives:
LVD: 2014/35/EU
EMC: 2014/30/EU
RoHS: 2011/65/EU
The complete Declaration of Conformity Document (DOC) is available upon request.

Imported by
HOF Trading B.V.
Fahrenheitstraat 11, 6003 DC Weert , The Netherlands Made in P.R.C.