VIMAR 01415 Gateway IoT for Integration Two Wire Plus Video Intercom System Instructions

June 28, 2024
VIMAR

VIMAR 01415 Gateway IoT for Integration Two Wire Plus Video Intercom

System

VIMAR-01415-Gateway-IoT-for-Integration-Two-Wire-Plus-Video-Intercom-System-
product

FEATURES

  • Power supply from terminal BUS 1, 2 – rated voltage 28 Vdc

Absorption

  • in standby: 120 mA
  • in transmission (to supervisor devices or mobile App): 300 mA
  • Connection to the LAN network via RJ45 socket outlet (10/100/1000 Mbps)
  • Minimum video signal level on the bus for reception: -20 dBm
  • With 5 backlit control buttons
  • Input for landing call.
  • Input for additional power supply: only code Elvox 6923, 28Vdc 0.5A INT
  • Dip switch for line termination impedance
  • Operating temperature: – 5 +40 °C (indoor use)
  • Operating ambient humidity 10 – 80% (non-condensing)
  • IP30 degree of protection

CONNECTIONS

  • RJ45 socket outlet for connection to LAN network
  • Ethernet cable: UTP cable category CAT. 5e or superior
  • Maximum Ethernet cable length: 100 m
  • The gateway enables the transfer of information between the Due Fili Plus bus and an IP network; with an Internet connection, all remote management functions for both the installer and end user can be enabled via the cloud. For an overview of the integrated architecture, see the figure EXAMPLE OF INTEGRATED INFRASTRUCTURE. OPERATION.
  • Configuration of Due Fili Plus system.
  • Association to touch screens 01420, 01422 and 01425.
  • Firmware updating.
  • Functions available from the touch screen:
    • Outdoor unit self-starting.
    • Outdoor unit lock opening.
    • Audio intercom calls.
    • Activating system actuation (stair light, auxiliary functions).
    • System contacts list and favourites menu for quick access.
    • Configurable video voicemail.
    • Adjust audio and video call settings.
    • Input for landing bell.
    • Support for CCTV integration.
    • Support for remote call service on smartphone/tablet.

AUXILIARY POWER SUPPLY MODE

VIMAR-01415-Gateway-IoT-for-Integration-Two-Wire-Plus-Video-Intercom-System-
fig- \(1\)
The choice of device power supply is defined via the specific dip switch.
Note: To power the device via the Due Fili bus only, place the dip switch to ON.

VIDEO TERMINATION
To terminate the video signal set the dip switches as follows:
VIMAR-01415-Gateway-IoT-for-Integration-Two-Wire-Plus-Video-Intercom-System-
fig- \(2\)

KEY FUNCTIONS

  • F1= Cloud-gateway connection emergency procedure activation key
  • Press and hold down F1 (for 10 s) to reset the network configuration in DHCP and re-establish connection with the Cloud.
  • LED 1 is switched on when the gateway is working properly whereas it is switched off when the device is not working or the Cloud is enabled but not reachable.
  • LED 1 flashes when the device is reset via the Installer App; the gateway is restarted at the end of the operation.
  • During the emergency procedure, LED 1 flashes (at least 2 s) to indicate the start of the operation; once the operation is complete, LED 1 switches on or off depending on the status of the device.
  • F2= New IP address request from DHCP server and gateway reset key
  • Press F2 briefly to restart the DHCP client and request a new address from the DHCP server; in the case of static IP configuration, no action is carried out.
  • LED 2 remains permanently lit when an IP address (static or dynamic) is assigned to the device whereas it remains switched off if no address is assigned; LED flashes when the DHCP server is not present or reachable.
  • Press and hold down F2 (for 10 s) to reset to the default settings; all the LEDs on the device are switched off.
  • F3= Firmware updating and gateway restart key

Manual firmware updating
Press and hold down F3 (10 s) until LED 3 starts to flash.

  1. Connect the PC to the device via a USB cable; an external disc is displayed on the PC (UPDATE).
  2. Copy the files supplied by the Customer Service Centre.
  3. After the files have been copied, remove the UPDATE drive from the computer safely (“safe removal” on Windows, “expel drive” on macOS).
  4. Press and hold down F3 again (10 s); LED 3 remains on to signal that the update is in progress.
    IMPORTANT: Do not remove the power supply from the gateway; the device is then automatically restarted. At the end of the procedure LED 3 switches off.

Restarting the gateway

  • Press and hold down F3 (10 s) until LED 3 starts to flash.
  • Press and hold down F3 again (10 s); LED 3 remains on for a few moments and then the complete gateway restart begins.
  • F4= Configuration key in the Due Fili system
  • The gateway must be configured in the Due Fili Plus bus only as primary.
  • Press and hold down F4 (10 s) until LED 4 starts to flash.
  • Assign the ID to the gateway
    • for Master entrance panels, press the button to associate;
    • For alphanumeric entrance panels, enter the address (ID) to be assigned and then press the Confirm key.
  • At the end of the procedure, LED 4 remains on to signal normal operation.

CONF User association enabling key

  • Press CONF briefly; LED 5 switches on and remains permanently lit.
  • LED 5 switches off at the end of the enabling process or, if the operation is unsuccessful, it switches off after 3 min.
  • N.B. To enable the gateway association with the Installer, the device must not yet be configured.
  • Pressing CONF repeatedly does not restart the procedure.

INSTALLATION RULES

  • Installation must be carried out by qualified persons in compliance with the current regulations regarding installing electrical equipment in the country where the products are installed.
  • The RJ45 network interface 10/100/1000 Mbps must only be connected to a SELV network (Safety Extra-Low voltage).
  • WARNING: Update the firmware to the latest version! You can download it via the cloud (with the device connected to the Internet) or from www.vimar.com Download Software View Pro.
  • Version 1.13.1 can only be installed if version 1.12.1 was installed first.
  • The View Pro App manual can be downloaded from the www.vimar.com website using the gateway article code.

REGULATORY COMPLIANCE.
EMC directive. Standards EN 60065, EN 61000-6-1, EN 61000-6-3. REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.

WEEE – Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the product must not be included with other general waste at the end of its working life. The user must take the worn product to a sorted waste center, or return it to the retailer when purchasing a new one. Products for disposal can be consigned free of charge (without any new purchase obligation) to retailers with a sales area of at least 400 m2 if they measure less than 25 cm. An efficient sorted waste collection for the environmentally friendly disposal of the used device, or its subsequent recycling, helps avoid the potential negative effects on the environment and people’s health and encourages the re-use and/or recycling of the construction materials.

FRONT VIEW

VIMAR-01415-Gateway-IoT-for-Integration-Two-Wire-Plus-Video-Intercom-System-
fig- \(3\)

  • Terminal covers which must be removed for wiring cables on H and L
  • USB port for firmware updating
  • F1 (Key 1/LED 1)
  • F2 (Key 2/LED 2)
  • F3 (Key 3/LED 3)
  • F4 (Key 4/LED 4)
  • CONF (Key 5/LED 5)VIMAR-01415-Gateway-IoT-for-Integration-Two-Wire-Plus-Video-Intercom-System-fig- \(4\)
  • Video termination dip-switch
  • Auxiliary power supply dip switch
  • RJ45 socket outlet for Ethernet cable connection

CONNECTIONS

VIMAR-01415-Gateway-IoT-for-Integration-Two-Wire-Plus-Video-Intercom-System-
fig- \(5\)

  • CONNECTING IN THE IN/OUT CONFIGURATION
  • CONNECTING IN TERMINAL CONFIGURATIONVIMAR-01415-Gateway-IoT-for-Integration-Two-Wire-Plus-Video-Intercom-System-fig- \(6\)

Wiring diagram with cable terminating in the internal unit

VARIANT FOR CONNECTING THE LANDING BUTTON

VIMAR-01415-Gateway-IoT-for-Integration-Two-Wire-Plus-Video-Intercom-System-
fig- \(8\)

  • Door call button (NO contact)
  • Terminals on board the 01415

CAUTION: The electrical installation of the gateway phone requires the connection of one supplementary power supply 6923 for each gateway 01415.

EXAMPLE OF INTEGRATED INFRASTRUCTURE

VIMAR-01415-Gateway-IoT-for-Integration-Two-Wire-Plus-Video-Intercom-System-
fig- \(9\)

  • By-me Plus SYSTEM
  • SYSTEM By-alarm Plus
  • ELVOX VIDEO DOOR ENTRY 2F+
  • ELVOX VIDEO DOOR ENTRY IP
  • ELVOX CCTV

Viale Vicenza, 14
36063 Marostica VI – Italy
49401433B0 06 2405 www.vimar.com