JBC BIN-5A Battery Powered Nano Soldering Station Instruction Manual
- June 26, 2024
- JBC
Table of Contents
BIN-5A Battery Powered Nano Soldering Station
“`html
Specifications:
-
Model: Battery-Powered Nano Soldering Station
-
Available References: BIN-5A (with Portable Display), BIN-5QA
(without Portable Display) -
Power Cord Options: 120V – N. America / Taiwan, 230V – India /
Europe / United Kingdom
Product Usage Instructions:
1. Station Setup:
Display Holder Assembling:
-
Insert the thin end of the display holder into the upper area
of the rear rail of the charging base. Then rotate the display
holder 90 degrees until it stands vertical. -
Insert the fixing knob and tighten it just enough so that it
stays in place but the display holder can be moved.
Base and Display Connection:
-
Connect the charging base to the mains.
-
The display can be connected to the USB port with the provided
USB cable to keep it charging while working. -
Place the display on the support with its buttons facing
upwards. Adjust the height of the display holder and tighten the
fixing knob.
2. Station Set Up (continuation):
Cartridge Exchanger:
- The exchanger is suitable for C115 and C210 cartridges.
- The cartridge exchanger allows inserting/changing cartridges
safely without switching the tool off. Cartridges are held in place
thanks to the retention clamps.
FAQ:
Q: How long does the battery last on a full charge?
A: The battery life may vary based on usage, but typically, a
full charge can last for several hours of continuous use.
Q: Can I use third-party cartridges with this soldering
station?
A: It is recommended to use compatible cartridges to ensure
optimal performance and safety of the soldering station.
“`
INSTRUCTION MANUAL
B·IRON NANO
Battery-Powered Nano Soldering Station
This manual corresponds to the following references:
BIN-5A – with Portable Display BIN-5QA – without Portable Display
Packing List
- Depending on customer requirements, various power cords are available, suitable for:
120V – N. America / Taiwan 230V – India / Europe / United Kingdom
The following items are included:
Charging-Base with RightSide Charging-Holder already assembled ……… 1 unit
C115 Cartridge …………….. 1 unit Ref. C115101 (tip ø 0.1 mm)
B·NANO Nano Handle for B·IRON ……………….. 1 unit Ref. BN-A Includes Nano Handle + B1596 Safety Cap + OB5000 Sealing Plug + B1510 Grip + fitters.
Brass Wool for B·IRON Charging-Base ………….. 1 unit Ref. CL0300 Already assembled in the charging base.
B·IRON Display Holder 5″ to 7″ ………………………… 1 unit Ref. 0030723 Includes fixing knob.
USB Cable ** (USB A to Micro USB) ………. 1 unit Ref. 0028092
Power Cord * ………………………………………… 1 unit Ref. 0027380 120V – N. America / Taiwan
0027381 230V – India 0027382 230V – Europe 0027378 230V – United Kingdom
- One power cord included according to customer requirements. ** Not included in ref. BIN-5QA.
2
Portable Display 7″ for B·IRON ** …….. 1 unit Ref. PDS-B
Quick Start Guide ………………………………… 1 unit Manual …………………………………………………… 1 unit Ref.
0033719
Important
Please read this manual and its safety guidelines thoroughly before using the
product. Note: Even if the display is turned off and the charging base is
disconnected from the mains, the tool remains operational as long as the
batteries are charged, even when the cartridge is taken out.
The tool turns off automatically only under the following conditions: – When
the tool is out of the charging holder (no cap fitted) and remains completely
still
for 5 minutes (see page 9). – When the safety cap is fitted onto the tool and
the tool remains completely still for 60
minutes (see page 10). The tool can be manually switched off and on by tapping
the tool power button on the display (see page 9).
Features and Connections
PDS* Portable Display 7″
for B·IRON
Cartridge Exchanger
CL0300 Brass Wool for B·IRON Charging-Base
(inside)
- Not included in ref. BIN-5QA
Cartridge Holder
H2465 Right-Side ChargingHolder for B·IRON Handles
CL0301 Wiper for B·IRON Charging-Base
BCB Charging-Base for B·IRON
3
Features and Connections
PDS * Portable Display 7″
for B·IRON
USB Cable * Ref. 0028092
Bluetooth Connection
B·IRON Display Holder 5″ to 7″
Ref. 0030723
Display Support
B·NANO Nano Handle for B·IRON
Safety Cap Holder
USB Connector
C115 Cartridge
Range
Power Socket B1596
Safety Cap for B·IRON Handles
- Not included in ref. BIN-5QA
4
Station Setup
Display Holder Assembling
Display Holder Setting
1
2
1
Display Holder
Insert the thin end of the display holder into the upper area of the rear rail
of the charging base (1). Then carefully rotate the display holder 90 degrees
(2) until it stands vertical.
Insert the fixing knob (1) and tighten it just enough so that it stays in place but the display holder can be moved.
Base and Display Connection
Display Placing
Power Button 1
2 1
Connector for Display
Support
Connect the charging base to the mains (1).
The display can be connected to the USB port (2) with the provided USB cable
to keep it charging while working.
Place the display on the support with its buttons facing upwards (1). Adjust
the height of the display holder tighten the fixing knob.
Turn on the display by holding down the power button for a while (1) and then
open the B·IRON app*:
- Note: The app can also be downloaded to your own devices. To know how, see section “Installing and Updating the B·IRON App”.
5
Station Set Up (continuation)
Cartridge Exchanger
Retention Clamps
1
The exchanger is suitable for C115 and C210 cartridges.
C115 Cartridges
The holding area of C115 Cartridges is delimited by the two
rings at the cartridge shaft (x). x
C115 Cartridge
The cartridge exchanger allows to insert / change cartridges safely without switching the tool off. Cartridges are held in place thanks to the retention clamps (1).
C210 Cartridges The holding area of C210 Cartridges goes from the collar of the tip until the cartridge begins to widen (x).
C210
x
Cartridge
Cartridge Changing
Cartridge Fixing
Tool Charging
2
1
1
Cartridge Exchanger Place the tool with the cartridge over the cartridge
exchanger slots and press down (1) until it clicks. To remove the cartridge
pull the handle out (2).
To insert a cartridge, carry out the same steps as before in reverse order.
6
1
Gently press the tip against the holes on the sides of the cartridge exchanger
(1) to ensure that the cartridge is appropriately inserted.
Important: Cartridges must be inserted uuppttooththeeremfearreknfcoer
rainpgrofoprear cporonpnerctcion.nection.
Ring Mark
Place the tool in the charging holder (1) to charge it. A beep will sound when
the tool is properly placed and charging. The volume can be adjusted using the
left button on the display.
Important: Charge the tool completely before using it for the first time. A
full charge takes: -30 min for B·100 -60 min for B·500 -30 min for B·NANO -40
min for B·TWEEZERS
Operation
Thanks to the intelligent heat management, the cartridge tip recovers temperature extremely quickly. This allows reducing the tip temperature when the device is not in use, resulting in a longer tip lifespan. When the tool enters the sleep or hibernation states, the tip temperature lowers automatically below the solder-melting-point temperature (1).
Temp.
Work temp.
Sleep temp.
Work
Room temp.
0
Tip Temperature
Sleep (time selectable)
1 Hibernation
Tool in charging holder Heating
Work Time
Tool Status and Tip Temperature
The tool can go into a number of states under different circumstances (see the diagram on the next page). Depending on the status, the cartridge tip reaches different temperatures:
Tool Status Sleep & charging Hibernation & charging
Tip Temperature
Cools down to the set sleep temperature. Selectable between 70 °C and 150 °C.
Cools down to room temperature.
Working Resting w/o cap Tool with cap on
Hibernation
Heats up to the set work temperature.
Cools down to room temperature (after 5 min of being completely still).
Cools down to room temperature.
Cools down to room temperature.
Shut off
Remains at room temperature (tool is shut off).
Sleep & Charging
Sleep Mode can be aJctBivaCted/deactivated (2). If it is activated and the
tool is placed in the charging holder, in addition to charging, the tip
temperature cools down to sleep temperature.
Hibernation & Charging
If Sleep Mode is not activated and the tool is placed in the charging holder,
besides charging, it goes into hibernation and the tip temperature cools down
to room temperature.
JBC
MENU Return to Work
JBC
210
2
JBC#1
Tool ID
TTooooll11
2822
Hibernation delay
0100:30
Temperature units
ºC
ºF
Lock Parameters
Locked
Unlocked
Maximum Temperature
400ºC
Sleep mode Sleep temperature
150ºC
Tool Status Working Low battery Power OFF
Charging No cartridge
7
Tool Status and Tip Temperature (continuation)
1
SLEEP
& charging
after 5′
2
HIBERNATION
& charging
Sleep OFF
no charging
Sleep ON tool cap placed on
tool is picked up
tool in
CHARGER
charging
8
tooltotoacchtiavragteerit
SHUT OFF
7
after 60′
tool to charger
6 after 5′
HIBERNATION
HIBERNATION
tool laid
4 down
between
5″…10″
3
WORK
5
Work
When the tool is taken out of the charging holder during the sleep (1) or the
hibernation state (2), the cartridge tip heats up to the set work temperature
and the tool is ready to use (3).
Hibernation
The tool goes into hibernation in two different cases: a) After working, when
the tool is laid down (4) and is resting between 5 and 10 seconds (time is
adjustable). b) After working, when the tool cap is fitted on (5).
Note: Before the tool enters hibernation, it can be picked up to work with it
and the cartridge tip heats up to work temperature.
Auto Shut-off
The tool shuts off automatically in two different cases: a) When the tool (w/o
tool cap) is laid down and remains in hibernation for 5 minutes (6). b) When
the tool, with the tool cap on, remains in hibernation for 60 minutes (7).
8
Tool Status and Tip Temperature (continuation)
JBC
Tool Reactivation
Once the tool has automatically shut off, place it back in the charging holder
(8) to reactivate it (see diagram on previous page).
Manual Tool Shut-Off
Besides the “automatic shut-off” feature, the tool can also be manually
switched off by tapping the tool power button on the display. When it is
switched off, the cartridge cools down to room temperature.
Note: To switch the tool back on, tap the same button on the display.
350ºC
Safety Cap
12 W
6 W
10 seconds/div
Tool
ON
0 W V1.2
Tool on/off button
Thanks to the tool’s safety cap, B·IRON tools can be carried around safely,
even with the cartridge inserted. When the cap is placed onto the tool, it
goes in hibernation immediately and the cartridge tip cools down to room
temperature.
Note: The purpose of the cap is to allow safe transport, not storage.
Safety Cap Holder
While the handle is in use, the safety cap can be stored on the cap holder
located on the back of the charging base. There is space for two caps.
The cap holder is detachable. If desired, it can be removed by unscrewing it.
Screw
Cap holder
9
Tool Connection
Make sure that the charging base is connected to
the mains. JBC
Note: The supplied tool is already connected.
Scanning another tool: (This process can take a while) Place the tool in the
charging holder to activate it. The status light band color indicates the
charge level (see table below). If the scanning process does not run
automatically, tap “scan” (6) on the display while the tool remains in the
charging holder. When the tool is shown in the device list on the display,
select it (11) and tap “connect” (7). Now the tool is ready for soldering.
9 11
Device List
6 7
8 10
Tool search function: When in doubt of which tool corresponds to the tool’s name, use the tool search function. Tap on the magnifying glass symbol (8) next to the tool’s name. The light band on the corresponding tool blinks in blue for five seconds to identify it.
Working with two tools (works also for charging bases with only one charging holder): It is possible to connect up to two tools at the same time. If a tool is already connected, first disconnect it from the device by selecting “Menu” (9) and tapping on “Disconnect”.
Place the second tool in the charging holder and scan it (6). The second tool is also shown in the device list on the display (10). To work with two tools, select one from the left-hand column (11) and the other one from the right- hand column (10). Then tap on “connect” (7).
Status Lightband
The status lightband on the tool indicates its status (see table on the
right).
Safety Cap
Status Lightband Detail
10
Color
Green
Orange
Red
Green blinking Orange blinking
Red blinking
No color
Tool Status
More than 50% charged
Between 20% and 50% charged
Less than 20% charged
Charging (more than 50% charged)
Charging (between 20% and 50% charged)
Charging (less than 20% charged) Safety cap on the handle
and/or power off
Blue blinking
Locate Tool function activated
Workscreen
The workscreen shows a graph of the tip temperature and power supplied to the
tip updated in real time. It allows modifying the tool working temperature,
checking the battery status and turning the tool in use on and off.
Temperature and Power Graph
MENU
JBC
210
450 ºC
CHARGE
JBC#1
24 W
350 ºC
348ºC
18 W
250 ºC
12 W
150 ºC
6 W
6 W
50 ºC
80%
Temperature Scale
350ºC
0 W 10 seconds/div
Tool
ON
V1.2
Working Temperature Selection Slider
Power Scale
Graph and Automatic Data Display
The graphs of temperature and supplied power start automatically as soon as
the tool is lifted from the charging base.
The graph display can be paused while working by tapping the screen on the
graph area. While the automatic display is on hold, the temperature/power
values can be checked at a certain point of the graph by tapping on the
desired position on the display screen.
Note: Pausing the automatic display by tapping on the screen does not stop the
tool from heating up, and the tip will remain at the selected working
temperature. The graph display automatically continues after 5 seconds.
The graph can be moved to the left and right by swiping the touch screen
sideways with one finger.
Working Temperature Modification
The working temperature can be modified using the slider below the graph (± 5
°C / ± 10 °F).
11
MENU
450 ºC 350 ºC
JBC
CHARGE
348ºC
Connected Tool and Tool Selector
210
JBC#1
24 W
18 W
250 ºC
12 W
150 ºC
50 ºC
80%
6 W
350ºC
When the tool is not in use the graph stops recording
6 W
0 W 10 seconds/div
Tool
ON
V1.2
Stopping Data Display
When the tool is placed in the charging holder or when it enters Hibernation
Mode, the data display stops.
The display starts again automatically when the tool is lifted from the tool
holder and the graph is automatically displayed again at the point where the
previous display stopped, leaving a small gap on the graph between the last
registered value and the new starting point.
Working with Two Tools
When working with two tools, to switch between the two graphs, tap on the tool
selector (upper-right corner of the display) and select the desired tool from
the drop-down menu.
It is also possible to alternate both graphs by simply lifting one tool or the
other from the tool holder. The display will automatically show the graph and
information of the tool in use.
Note: All menu items are explained in detail starting at section “Menu”.
12
Menu
TJooBl CConnected:
MENU
Once at least one tool
Work
JBC has been linked, the
450 ºC
Settings
menu expands and shows more options.
Counters
350 ºC
Update
2L5o0cºCate Tool
Documents
150 ºC
Light Theme
Dark Theme
50 ºC
80% Disconnect
No Tool Connected: JBC MENU
Before any tool is connected to the station
Devices
450 ºC
Documents
or after the last tool has been disconnected, the menu offers these
Light Theme
350 ºC
Dark Theme
options.
250 ºC
150 ºC
50 ºC 80%
JBC
JBC JBC Work:
JBC
Takes the user to the workscreen (see section
MENU
Work
JJBBCC
210
JBC#1
“Workscreen”).
Tool ID
Tool1 2822
Lock Parameters
Locked
Unlocked
Sleep mode Sleep temperature
150ºC
Settings:
Hibernation delay (seconds)
Minimum Temperature
Maximum Temperature
The B·IRON app offers an intuitive user interface, which provides quick access to several station parameters (see next page).
00:30
Tool Status Working Low battery Power OFF
Charging No cartridge
100ºC
Temperature units
ºC
ºF
400ºC
JBC Counters:
The Counters section allows the user to consult data and counts on charges,
work state periods,
sleep state periods, JerBrorCs… The data can be consulted either by timeJpeBriCods or by number of times a certain event has occurred.
Update:
AseJllcotwBiosnuC”pUdpadtiantgintghethfeirmFiwrmawreaoref “t.he soldering
station. To know more about the updating process, see
Locate Tool: When in doubt of which tool corresponds to the tool’s name, use the tool search function, tapping on “Locate Tool”. The light band on the corresponding tool blinks in blue for five seconds to identify it.
Documents:
JBC
JBC
User manuals related to the station or to the tools can be consulted in this section or on JBC’s
website: www.jbctools.com
Light/Dark Theme: Allows the user to switch between dark and light display modes.
Disconnect: Disconnect the tool in use. If only one tool is connected, after disconnecting it, the app returns to the device list display.
13
Settings
Parameter Tool ID Lock parameters
Sleep Mode / Sleep temperature Hibernation delay
Minimum temperature Maximum temperature Temperature units
Description
Allows modifying the tool identifier. Allows locking the parameters of the
station using a four-digit code. The default code is 0105, but a new code can
be set by simply entering some other four digits of choice when locking the
parameters. Set Sleep Mode on/off. The tip temperature drops only to the
selected Sleep temperature when placed on the tool holder. Set Hibernation
delay from 5 to 15 sec. The countdown starts when the tool remains inactive
(no movement). Select the minimum temperature that can be set for Work Mode.
Select the maximum temperature that can be set for Work Mode.
Allows changing the units of temperature measurement between degrees Celsius
and degrees Fahrenheit.
Compatible Cartridges
B·NANO Handle works with C115 Cartridges. Find the model that best suits your
soldering needs on www.jbctools.com
Inserting C115 Cartridges
Push the cartridges inside the handle until the reference ring rests against
the sealing plug.
Conical
Chisel
Conical Bent
Bevel
C115 Cartridge Adapter (B0643)
Since C115 Cartridges have a smaller diameter than C210 Cartridges, adapters must be used to store them in the cartridge holder. These adapters must simply be inserted from above into the slots of the cartridge holder.
Cartridge Adapter
Reference Ring
Reference Ring
14
Wiper and Tip Cleaner
Select the tip cleaning option that best suits your needs and improve the tip thermal transfer.
CL0301 Wiper for B·IRON Charging-Base includes an anti-splash area that prevents solder particles from splashing onto the working area, keeping the workplace clean.
It also includes a temperature-resistant wiper area for removing excess solder by gently tapping or wiping the cartridge tip on it.
Tapping
Wiping
Brass Wool (inside)
Wiper area
Anti-splash area
Tap gently to remove excess solder.
Use the slots to remove remaining particles.
Note: If the tip is very dirty, JBC recommends cleaning it first with the wiper to remove excess solder and then with the brass wool.
CL0300 Brass Wool is a very effective cleaning method. It leaves a small layer of solder on the tip, preventing oxidation between cleaning and rewetting.
Replacing Brass Wool
Wiper rotated 180 degrees
Lift the wiper membrane by using the recess on the edge. Remove the wiper and replace the brass wool with a new one. Make sure that the brass wool is on the far left and that there is space for the wiper on the right.
Press the wiper membrane down at the 4 corners until you feel it click into place. Make sure that the wiper membrane is inserted correctly all the way around.
Note: The brass wool and the wiper positions can be reversed by rotating the antisplash membrane 180 degrees.
15
JBC Software
The app is already installed on JBC’s B·IRON Display. If another display is to
be used, the app must be downloaded to the corresponding display (see chapters
below).
At the moment of purchasing the B·IRON tool, the current firmware is already
downloaded to the tool.
Note: Since the tool firmware is not updated automatically, updates must be
carried out by the customer. To do so follow the instructions on the next
page.
App Versions
If an app with version 1.6 or higher is already installed on the display
(tablet or smartphone) used with B·IRON, the firmware of the tool can be
updated directly without updating the app. Carry out the steps described in
section “B·IRON Tool Firmware Update”.
Older app versions must be updated. If no app has been installed, it must be
installed first.
App Installation
On JBC’s portable display (Android), the B·IRON app is already installed.
On the user’s smartphone or tablet (Android / iOS), go to the App Store/Play
Store and search for “JBC B.IRON” on the search bar. Note: Internet connection
is required to download the app.
Alternatively, scan these QR codes to access the B·IRON app page directly:
App Update Display withJInBterCnet connection (Android / iOS)
JBC
Update the app via Google Play (Android) or the App Store (iOS).
Display without Internet connection (Android)
Download JBC’s installer program to another device with an Internet connection from JBC’s website: https://www.jbctools.com/jbcsoftware.html
Then copy the downloaded program to the internal storage of the display used with B·IRON. Access the internal storage of the display and run the downloaded program. Once the program is completed, the app will be updated to its newest version. Note: For JBC´s displays, swipe down to open the internal storage folder.
16
JBC
JBC
Downloading the Tool Firmware Update File
Display with internet connection: Download the firmware update file to the
display used with B·IRON from: https://www.jbctools.com/ jbcsoftware.html. Go
to the internal folder and unzip the downloaded file. Display without internet
connection: Download the firmware update file to another device with an
internet connection from JBC’s website:
https://www.jbctools.com/jbcsoftware.html and unzip the downloaded file. Then
do as described in the table.
PDS JBC’s display (android)
Other android devices
iOS devices
Copy the unzipped files on the device used with B·IRON:
Folder:
Internal shared storageAndroiddata es.infinitysource.jbc_
soldering.JBCBironfiles
Folder:
Internal shared storage Androiddatacom. jbctools.jbcbironfiles
Path:
Files > On my iPad > JBC B.iron
Executing the Tool Firmware Update File
Tool firmware be carried out
updates are by the user.
nJot BexeCcuted
automatically;
they
must
On the display you are using with the B·IRON, and the latest app version installed, access the B·IRON app:
Select he tool you want to update. Then in the main menu select “update”.
Note: At least one tool must be linked to see the expanded menu options.
JBC
Main Menu with expanded menu options
MENU Work
450 ºC
Settings
Counters
350 ºC
Update
2L5o0cºCate Tool
Documents
150 ºC
Light Theme Dark Theme
50 ºC 80%
Disconnect
JB1C7
Executing the Tool Firmware Update File (continuation)
If the downloaded tool firmware update file contains a newer version than the one already installed, the current and new version are displayed (1). Tap “Update” to start the update (2).
The update process takes about 10 minutes.
1
2 The B·IRON status light continuously changes its color during the
update process.
Once the update is completed, “Tool updated” (3) will be displayed. 3
If “No new version available” is displayed (4), no update is possible
or required. 4
Accessories
B·IRON Display Holder 10″ to 13″ Ref. 0031246
Display Holder
Mount on charging base
In addition to the display holder supplied with the B·IRON station, JBC offers a holder for tablet sizes between 10″ and 13″.
18
Accessories
Soldering Tools for B·IRON Stations B·NANO Nano Handle for B·IRON
B·TWEEZERS Nano Tweezers for B·IRON
Ergonomic and lightweight soldering handle. Designed for use in labs and high-
precision soldering in hard-to-reach areas. Works with C115 Cartridges.
Powerful and efficient soldering tweezers. Designed for use in labs and
soldering rework job. Works with C115 Cartridges.
B·100* Light Handle for B·IRON
Ergonomic and lightweight soldering handle. Designed for use in labs and
individual soldering jobs.
Works with C210 Cartridges.
B·500* Handle for B·IRON
Powerful and efficient soldering handle. Designed for use in production and
intensive soldering jobs.
Works with C210 Cartridges.
- Cartridges not included. To charge the tools, a B·IRON charging-base or station is needed.
19
Accessories
Tool Expansion Kits for B·IRON
B·NANO K* Nano Handle Expansion Kit This kit allows to extend B·IRON station
with B·NANO Handle. Fully compatible with C115 Cartridges.
Charging Holder
Adapters for C115 Cartridges
Nano Handle Safety Cap
B·TWEEZERS K* Nano Tweezer Expansion Kit
This kit allows to upgrade B·IRON station to a rework station by adding
B·TWEEZERS.
Fully compatible with C115 Cartridges.
Charging Holder
B·100 K* Light Handle Expansion Kit
This kit allows to extend B·IRON station with B·100 Light Handle.
Fully compatible with C210 Cartridges.
Charging Holder
Safety Cap
Nano Tweezers Adapters for C115 Cartridges
Light Handle
B·500 K* Handle Expansion Kit
This kit allows to extend B·IRON station adding B·500 Handle.
Fully compatible with C210 Cartridges.
Charging Holder
handle Safety Cap
- Cartridge not included. To charge the tools a B·IRON charging base or station is needed.
20
Maintenance – Tool
Replacing B1510 Grips (Soft Foam)
Inserting Fitters
Assembling Grips
Removing Fitters
Fitter
New Grip
Handle
Insert the fitters into the new Push the grip with the fitters
grip.
onto the handle.
Hold this way so the fitters can slide
To remove the fitters, hold the grip and pull the fitters out. Use pliers if
necessary.
Replacing Sealing Plugs The sealing plug prevents undesirable flux vapors or particles from entering the handle. Its usage is highly recommended for intensive applications when soldering is exposed to FOD environments or for applications where the soldering iron works close to a vertical position.
Note: Choose between the two available sealing plug references depending on your handle model.
Before replacing the sealing plug, disconnect the handle from the station and make sure the device has cooled down.
Handle B·100 B·500 B·NANO
Sealing Plug OB4000 OB5000
Replacing Sealing Plug OB5000
For B115 handles, the use of the OB5000 sealing plug is mandatory. Without the use of the sealing plug, the cartridges cannot be properly inserted.
Sealing plug
Chamfered side
Handle
Sealing plug in touch with the bushing
Remove the worn sealing plug by unscrewing it by hand.
Position the chamfered side upwards and screw the new sealing plug into the handle bushing until it stops.
Make sure the sealing plug is placed correctly. The shoulder of the plug must be in touch with the bushing.
21
Maintenance – Station
Before carrying out maintenance, always extract the cartridge from the tool and disconnect the charging base from the mains. Allow the equipment to cool down.
– Use a damp cloth to clean the casing and the tool. Alcohol can only be used to clean the metal parts.
– Periodically check that the metal parts of the tool and charging holder are clean so that the charging works properly.
– Keep the tip surface clean and tinned prior to storage in order to avoid tip
oxidation. Rusty and dirty surfaces reduce heat transfer to the solder joint.
– Do not use liquids such as alcohol, thinner or benzene to clean the portable
display.
Clean the contact surfaces regularly to ensure that the tool gets charged correctly.
– Repairs should only be performed by a JBC authorized technical service.
Safety – Battery
It is imperative to follow safety guidelines to prevent electric shock,
injury, fire or explosion.
– Caution: This product contains lithium-ion batteries. Mishandling or
improper use may result in fire, explosion, or personal injury.
– Always use the provided charger. Do not use damaged chargers or batteries.
– Never attempt to disassemble or modify the batteries or the product. Doing
so may lead to electric shock, fire, or damage to the product.
– In the event of damage, leakage, or overheating of the batteries,
discontinue use immediately and contact customer support or JBC technical
service facility.
– Dispose of devices with batteries inside, responsibly according to
regulations. They must be disposed of in accordance with local regulations so
that they can be recycled.
– Do not throw devices with batteries into household waste and do not dispose
of them in fire or water.
22
Safety
It is imperative to follow safety guidelines to prevent electric shock,
injury, fire or explosion.
– Do not use the units for any purpose other than soldering or rework.
Incorrect use may cause a fire. – The power cord must be plugged into approved
bases. When unplugging it, hold the plug, not the wire. – Do not attempt to
dismantle or open the housing of the tool as it may cause damage. – Do not
work on electrically live parts. – The tool should be placed in the charging
holder when not in use in order to charge the batteries. – The soldering tip,
the metal part of the tool and the charging holder may still be hot even when
the
station is turned off. – Do not leave the tool unattended when it is on. –
Avoid flux coming into contact with skin or eyes to prevent irritation. – Be
careful with the fumes produced when soldering. – Keep your workplace clean
and tidy. Wear appropriate protection glasses and gloves when working
to avoid personal harm. – Utmost care must be taken with liquid tin waste,
which can cause burns. – This appliance can be used by children over the age
of eight and also persons with reduced physical,
sensory or mental capabilities or lack of experience provided that they have
been given adequate supervision or instruction concerning the use of the
appliance and understand the hazards involved. Children must not play with the
appliance. – Maintenance must not be carried out by children unless
supervised. – Do not expose the portable display to high temperatures,
humidity or dust. Avoid direct sunlight. – Do not drop the portable display or
the tool, as it may cause damage or malfunction. – Do not disconnect your
device when it is in file transfer mode. – Do not use the portable display in
places where wireless communications are restricted.
23
Notes
24
Notes
25
Notes
26
Specifications
B·IRON NANO Battery-Powered Nano Soldering Station Ref. BIN-5A – with Portable
Display Ref. BIN-5QA – without Portable Display
Charging Base – Input: – Nominal Power: – Tool Output: – USB Output:
B·NANO Nano Handle – Peak Power (Tool): – Battery: – Charge Time: – Selectable
Temperature: – Idle Temp. Stability (still air): – Temp. Accuracy: –
Connections: – Ambient Operating Temp.: – Tool Weight:
Portable Display 7″ – Display Dimensions:
Ref. BIN-5A with Portable Display: – Total Net Weight: – Total Package
Dimensions/Weight: (L x W x H)
Ref. BIN-5QA without Portable Display: – Total Net Weight: – Total Package
Dimensions/Weight: (L x W x H)
100 V – 240 V 50/60 Hz 40 W 12 V / 1000 mA 5 V / 1000 mA
24 W Li-Ion 7.4 V / 750 mAh 30 minutes 100 – 450 °C / 210 – 840 °F ±1.5 °C /
±3 °F ±3 % (using reference cartridge) Bluetooth Low Energy (BLE) 10 – 50 °C /
50 – 122 °F 30 g / 0.07 lb
7″ / 7 in
1.94 kg / 4.28 lb 265 x 223 x 160 mm / 2.52 kg 10.43 x 8.78 x 6.30 in / 5.55
lb
1.49 kg / 3.37 lb 225 x 223 x 160 mm / 2.03 kg 8.86 x 8.78 x 6.30 in / 4.54 lb
Complies with CE standards. Not grounded device. No ESD discharge feature.
27
Warranty JBC’s 2 year warranty covers this equipment against all manufacturing
defects, including the replacement of defective parts and labor. Warranty does
not cover product wear or misuse. In order for the warranty to be valid,
equipment must be returned, postage paid, to the dealer where it was
purchased. Get 1 extra year JBC warranty by registering here:
https://www.jbctools.com/productregistration/ within 30 days of purchase. If
you register, you will receive e-mail notifications about new software updates
for your registered product.
This product should not be thrown in the garbage. In accordance with the
European directive 2012/19/EU, electronic equipment at the end of its life
must be collected and returned to an authorized recycling facility.
0033719-120624
References
- JBC Soldering Stations, Irons and Rework equipment for electronics
- JBC Soldering Stations, Irons and Rework equipment for electronics
- JBC Software
- Warranty Extension
Read User Manual Online (PDF format)