SEAFLO SFIB1-130-01 In Line Blower Instruction Manual
- June 25, 2024
- SEAFLO
Table of Contents
IN-LINE BLOWER
INSTALLATION AND OPERATING INSTRUCTIONS
PRODUCT FEATURE
- SEAFLO In-Line Blower is mainly designed to provide ventilation for bilges, engine compartments, galleys and heads.
- Designed for efficient, high output operation, these blowers feature our exclusive front and rear shaft seals and corrosion resistant ABS housing for long life.
- Designed for easily installed on any flat surface. Computer optimized blade profile and housing design produce higher air flow, low amp draw and quieter operation than standard blowers.
INSTALLATION
- The blower must be used with a natural ventilation system that is open to the atmosphere.
- Mount the blower in the upper portion of the bilges, engine compartments, galleys and heads with two no.10 screws. Secure blower i place taking care not to over tighten screws or penetrate the hull.
- Position blower with flow arrow towards exhaust vent. (be sure to determine the correct direction of airflow before mounting) The in-line blower may be mounted on an angle to assure drainage from rainwater.
- Connect (01/03 series are 3 inches and 02/04 series are 4 inches) diameter inlet and exhaust duct with stainless steel hose clamp.
- The duct inlet opening should be permanently fixed and located above the normal bilge level and as practicable beneath the engine which it serves.
WIRING INSTRUCTIONS
- Connect the positive (+) red wire and negative (-) black wire crimp type connectors. Waterproof the connectors with sealant.
- The bilge blower wires must be protected with the same fuse amp (please see the ventilation parameter) installed in the positive (+) line.
- An on-off switch with the same fuse amp rating should be installed in the positive line.
- Minimum lead wire size should be 16 AWG (gauge).
OPERATING
-
Gasoline vapors can explore.
Warning -
Do not operate blower while refueling.
-
To prevent personal injury, always disconnect one of the main battery leads when installing or servicing this product.
-
Always use a fuse with amperage rating specified for the blower model. Failure to do so may result in serious personal injury or fire hazard.
BEFORE STARTING ENGINE
- Check engine compartment for gasoline or vapors.
- Operate blower at least five minutes.
SPECIFICATIONS
Model| Voltage (v)| Air Flow (CFM)| Amp Draw (A)| Fuse
(A)| Intake Pipe Dia(mm)
---|---|---|---|---|---
SFIB1-130-01| 12| 130.0| 2.5| 5.0| 3″/80
SFIB2-130-01| 24| 130.0| 1.3| 3.0| 3″/80
SFIB1-270-02| 12| 270.0| 6.0| 10.0| 4″/105
SFIB2-270-02| 24| 270.0| 3.0| 5.0| 4″/105
SFIB1-145-03| 12| 145.0| 3.0| 5.0| 3″/76
SFIB2-145-03| 24| 145.0| 1.5| 2.5| 3″/76
SFIB1-235-04| 12| 235.0| 4.0| 7.0| 4″/102
SFIB2-235-04| 24| 235.0| 2.0| 4.0| 4″/102