SEAFLO SFBS-18-02 Float Switch Instruction Manual
- June 7, 2024
- SEAFLO
Table of Contents
02 Float Switch
Instruction Manual
Model | SFBS-18-02 |
---|---|
Voltage | 12/24/32VDC |
Wire Size | 16 Gauge (1.2 mm) |
Wire Length | 1 m |
Max, Amps | 18 A (12 V) 8 A (24 V) 6 A (32 V) |
Guard | Ignition protected |
All mounting holes must be sealed with a marine grade sealant to prevent water intrusion.
Model: SFBS-18-02
Dimensions in Inches (Millimeters)
CAUTION
Switch must be mounted equal to or above the pump base for positive shut-off.
CAUTION
Keep all wire connections above the highest water level. Wires must be joined
with connectors and a marine grade sealant to prevent wire corrosion.
CAUTION
Always install proper size fuse to prevent damage. Should a short occur,
failure to install proper fuse could increase risk of pump malfunction and
potentially result in personal injury and / or fire hazard.
1
2
3
OR
4
- Testing the Float Switch
Wire Connection
Work Principle
CAUTION
Disconnect power from the system before working on the unit to avoid personal
injury, damage to the surrounding environment and/or damage to the unit.
- BROWN WIRE
- AUTO
- OFF
- MAN
- FUSE-SEE CHART
- BLACK WIRE
CAUTION
This unit is designed for fresh water and salt water ONLY. Using with any
other hazardous, caustic, or corrosive material could result in damage to the
pump and the surrounding environment, possibly exposure to hazardous
substances and injury.
Read User Manual Online (PDF format)