SEAFLO SFFTP5-025-01 Fuel Transfer Pump User Manual
- June 1, 2024
- SEAFLO
Table of Contents
SEAFLO SFFTP5-025-01 Fuel Transfer Pump
INSTRUCTIONS AND PRECAUTION
Please read all instructions and precautions before use
Model No. | SFFTP5-025-01 | SFFTP5-032-01 | SFFTP1-032-01 |
---|---|---|---|
Open Flow Rate | 2.5 GPM | 3.2 GPM | 3.2 GPM |
Operating Voltage | DC3V | DC3.7V | DC12V |
Battery Type | 2 pcs DD type | Lithium | NA, Cable |
Max Head | 1.5m from out port | 3.0m from out port | 3.0m from out port |
Suction Pipe Length |
Approx. 506mm
Discharge Hose Length|
Approx.1050mm
Operating Temp.|
+5°C~40°C (41°F~104°F)
Applicable Liquids|
Gasoline, Diesel, Kerosene, Light oil, Water
PRECAUTIONS FOR USE
These instructions are to ensure the product is used correctly, safely, and to prevent any possible risk or damage to the user and/or others people. SEAFLO shall not take any responsibility for any failure of product, malfunction and damages caused by improper use by the user or third parties
DANGER
If the directions of this sign are not followed, fatal accidents can happen and the user may die or get seriously injured.
Do not use for concentrated acids.
Only use on applicable liquids written on the specifications.
Do not use this pump for transferring the following liquids; Aceton, Benzen, Cresol, Ethyl, Phenol, ethyl, Concentrated caustic soda liquid, Nitric acid, Hydrochloric acid, Sulfuricacid, thinner or solvents, Etc.
Don’t close to flame when refuel.
WARNING
If the directions of this sign are not followed, accidents can happen or the user can get injured.
Do not refuel directly while the vehicle or equipment is turned on.
Do not leave the pump unattended.
Make sure to use the pump on a plat ground.
Do not allow children to operate the product without adult supervision.
CAUTION
the directions of this sign are not followed, the product can get damaged or the user can get injured.
After using the pump, do not keep it on its side or upside down.
Make sure to remove any left over liquid in the discharge hose after each use.
Do not alter or disassemble the pump.
Do not run the pump’ dry’ or let the pump idle without transferring.
Make sure to turn off the power after using the pump. Take out the battery if long time no use.
Do not shock the pump.
Do not use deteriorated or contaminated liquids and fuels.
Do not place the pump in a wet area.
Do not use this pump for hot liquids above 40°C(104°F).
Operate only in open, cool and well ventilated areas.
Stop and reset after 5 minutes of continuous use to prevent overheating.
Use only pure liquid without any debris.
Don’t use it for drinking water.
NAME OF COMPONENTS
Cable and Adaptor (only for SFFTP5-032-01)
Power Cable (only for SFFTP1-032-01)
DIRECTION FOR USE
Power Supply
SFFTP5-025-01(DD Battery)
-
Open the battery cover lid with slide up.
-
**Check the polarity directions embossed on the battery case.
**
-
Install two pcs DD batteries, slide down and close the battery cover.
-
Charge the battery for new machine or not use for a long time, then check if the indicated LED shows red.
-
When indicated LED turn to green from red, please pull charger out.
-
Plug in the cable connector.
-
Connect red cable to positive of battery, black to negative. The indicator LED turning on means power supply is OK.
How to Refuel
-
Insert the suction pipe into the supply tank. Place the nozzle into the receiving container to transfer liquid.
-
Turn switch ON.
-
Pull the nozzle lever and start supplying the liquid.
-
Release the lever when the liquid supply is completed.
-
Turn switch OFF.
-
Pulling the lever of the nozzle, lift it up.
-
Let the left-over liquid in the hose flow back into the tank.
-
Insert the nozzle in the nozzle holder for temporarily storage and take out for long time storage.
NOZZLE LEVER
Nozzle lever designed to operate in two different ways according to the application.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>