SEAFLO SFWAS1-20-03 Alarm Control System
STANDARD CONFIGURATIONS
Model Number | Voltage | Current | Alarm volume | N.W. | Wire Gauge Size/length |
---|---|---|---|---|---|
SFWAS1 -2 0-03 | 12 V DC | 20 Amp s. Ma x | 85D8 | 0.2KG | 16AWG/ 1000mm (Bilge |
Switch)
16AWG/ 100mm (Alarm Switch)
SFWAS2-10-03| 24VDC| 10 Amp s. M ax| 85D8| 0.2KG
INSTALLATION
Location
- Mount the switch vertically as shown in Fig. 1 (wires located uppermost). Locate the switch as close to the pump as possible to ensure the same water level.
- Prepare a mounting block. Do not fasten the switch directly to the hull. The mounting block should be a minimum of 1 0mm(3/8″) thick marine plywood epoxied to the hull.
- The switch base may be located up to 6mm (1/4″) higher, but NEVER located lower than the base of the pump.
Mounting
- Use the switch base (Fig. 1) or mounting ears (Fig. 2) as a template to mark pilot holes in the mounting block.
- Set drill depth gauge to avoid drilling through the hull. Drill two 3mm (1/8″) diameter pilot holes.
- Fasten the switch onto the mounting block with #8 x 1/2″(3.5mm diameter x 13mm) stainless steel screws (not supplied).
Testing
- After installation, press and hold your finger in the two recessed places for 3 seconds.
- If the wiring is correct, the pump activates.
- Remove the top finger, the pump stays on.
- Remove the bottom finger, the pump should turn off after a short delay. Fig 3 – Testing Switch
- Test with water in the bilge to confirm that the pump turns on and off properly. If not, reposition the switch to allow for activation.
- Regularly touch the two sensing points with your finger to check whether the function is valid.
- When there is dirt residue on the sensing point after long-term use, please clean it up in time to avoid the failure of the switch function.
DIMENSION DRAWING
WARNING
- Keep all wire connections above water level. Wires must be joined with butt connectors and a marine-grade sealant to prevent wire corrosion.
- Install red wires to the positive terminal only and black to the negative terminal only.
- Disconnect power from the system before working on the unit to avoid personal injury, damage to the surrounding environment, and/or damage to the unit.
- Max working draw 20Aat 12V, 10Aat24V.