3000K Simply Retrofits Flood Light MW 3CCT Instructions

June 27, 2024
Simply Retrofits

3000K Simply Retrofits Flood Light MW 3CCT

Cautions:

  1. Do not use an electric generator to test LED fixtures.
  2. Please abide by related country, regional, and local laws and regulations when installing this fixture.
  3. Please turn off the power before installation or maintenance.
  4. Proper earth grounding is required to ensure safety.

Notice

  1. To avoid the possibility of electrical shock or fire, the installation personnel must have professional electric knowledge.
  2. Please wear gloves to avoid injury before installation.
  3. If any smoke or spark of the wire happens, please turn off the power immediately and notify the relevant personnel.

Attention

  1. Please check if there is any damage during shipping. If so, please contact the manufacturer timely.
  2. Please read the installation instructions carefully to check whether all the accessories are complete. After confirmation, then install the fixture according to installation steps.

Installed with 1/2 Knuckle Mount (suitable for 15W-80W ) (b= AM)

  • Step 1 : Take the fixture out of the package
  • Step 2 : Match the hole of the rubber mat with the bracket, pass the wire through, and fix it with screws(Watch out not to scratch the wire); (figure 1.1)
  • Step 3 : Pass the wire through from the other bracket and fix it with screws. (Watch out not to scratch the wire). (figure 1.2)3000K-Simply-Retrofits-Flood-Light-MW-3CCT-fig-1

Installed with whole fixture (suitable for 15W-80W)

  • Step 1 : Take the fixture out of the package;
  • Step 2 : Finish the wire connection according to the right mode of connection (pay attention to positive wire, negative wire, and ground wire), (figure 1.3). and then put the wire into the lamp pole;(figure 1.4)
  • Step 3 : Loosen screws; Adjust fixture angles as per actual demands and tighten screws later; Angles of the fixture are adjustable(pass the bracket through the mounting surface, fix it with screws, then connect the wires as per proper wiring requirements). (figure 1. 5)3000K-Simply-Retrofits-Flood-Light-MW-3CCT-fig-2

Installation 2: Trunnion Mount

Installed with trunnion mount(suitable for all power of this series) 15W-80W (b= YM)

  • Step 1: Take the fixture out of the package;
  • Step 2: Run the glued wire through the hole in the mounting bracket and secure the fixture and bracket with an inner hexagon screw (Watch out not to scratch the glued wire) (Figure 6.1), Tighten the other bracket with screws. (figure 6.2)3000K-Simply-Retrofits-Flood-Light-MW-3CCT-fig-3

Installed with trunnion mount(suitable for all power of this series) 100W- 150W (b= YM)

  • Step 1 : Take the fixture out of the package;
  • Step 2 : Run the glue wire through the hole in the mounting bracket and secure the fixture and bracket with an inner hexagon screw (Watch out not to scratch the glue wire) (Figure 6.3), Tighten the other bracket with screws.(figure 6.4)3000K-Simply-Retrofits-Flood-Light-MW-3CCT-fig-4

Installed with whole Fixture(suitable for all power of this series)

  • Step 1 : Take the fixture out of the package;
  • Step 2 : Finish the wire connection according to the right mode of connection (pay attention to positive wire, negative wire, and ground wire). (figure 6.5)
  • Step 3 : Loosen screws; Adjust fixture angles as per actual demands and tighten screws later. (figure 6.6)Tips: Angles of the fixture is adjustable.3000K-Simply-Retrofits-Flood-Light-MW-3CCT-fig-5

Installation 3: Function adjustment

  • Step 1 : Open the metal plug and plastic plug counterclockwise with a screwdriver (figure 9.1), then slide the switch up and down to adjust the power controller, CCT controller or photocell controller in your demand. (figure 9.2)3000K-Simply-Retrofits-Flood-Light-MW-3CCT-fig-6
  • Step 2 : After adjusting the required conrol function(figure 9.3), tighten the metal plug and the plastic plug clockwise.(figure 9.4)3000K-Simply-Retrofits-Flood-Light-MW-3CCT-fig-7

Warning
MIN 75 °C SUPPLY CONDUCTORS THIS PRODUCT MUST BE INSTALLED FOLLOWING THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED SUITABLE FOR OPERATION IN AMBIENT NOT EXCEEDING 50°C.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Simply Retrofits User Manuals

Related Manuals