ZURN ZER-HYD Series Automatic Sensor Operated Gear Driven Type Flush
Valves
Water Closet Battery Models:
- ZER6000AV-ONE-HYD 1.1 gpf
- ZER6000AV-HET-HYD 1.28 gpf
- ZER6000AV-WS1-HYD 1.6 gpf
- ZER6000AV-DF-HYD 1.1/1.6 gpf
- ZER6000AV-DF-HET 1.1/1.28 gpf
Urinal Battery Models:
- ZER6003AV-ULF-HYD 0.125 gpf
- ZER6003AV-EWS-HYD 0.5 gpf
- ZER6003AV-WS1-HYD 1.0 gpf
Compliance:
- ADA Compliant
- ASSE 1037/ASME A112.1037/CSA B125.37
- cUPC
- Texas Accessibility Standard (TAS)
- WaterSense Compliant
- WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov
LIMITED WARRANTY
All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are approximate and are not guaranteed.
NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT
FCC STATEMENT
Electronic emission notices
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. The following
information refers to Zurn Smart Connected Products, types: -W2. This
equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference
intended for use in non-residential/non-domestic environments. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult an authorized dealer or service representative for help.
Zurn is not responsible for any radio or television interference caused by using other than specified or recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user’s authority to operate the equipment.
User manual notice
This device contains license-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s license-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Warning the user to maintain 20cm of separation from the device
Specifications
- Sensor Range : 12” to 60” (adjustable)
- Voltage : 3.2 VDC Rechargeable (LiFePO) Battery with 3.0 VDC Backup batteries [ 2 “AA” 1.5V Alkaline Cells in Series]
- Operating Water Pressure : 25 psi [172 kPa] (Running); 80 Psi [552 kPa] Max (Static)
- Operating Temperature: 35°F to 104°F [2°C to 40°C]
Important Safety Information
- Do not convert or modify this Zurn product. All warranties will be voided.
- All plumbing is to be installed per applicable codes and regulations.
- Water supply lines must be sized to provide an adequate volume of water for each fixture.
- Flush all water lines prior to making connections.
- Do not use pipe sealant or plumbing grease on any fitting other than the control stop inlet.
- Sensor units should not be located across from each other or near highly reflective surfaces.
- The control stop should never be opened to allow flow greater than the fixture is capable of evacuating. In the event of valve failure, fixture must be able to handle a continuous flow.
Prior to Installation
- Before installing your flush valve, the items listed below should already be installed on-site:
- Water closet or urinal fixture
- Fixture carrier
- Drain line
- Water supply line
Package Contents
NOTE: The information in this manual is subject to change at any time without notice. Installations may be performed at different times of construction by different individuals. For this reason, these instructions should be left on-site with the facility or maintenance manager.
Required Tools
Optional Accessories
Sweat Solder Adapter Installation Instructions
NOTE: Before installation, turn off water supplies to the existing fixture and remove the flushometer if replacing an existing device.
- Measure the distance from finished wall to the center line of the fixture spud. If necessary, cut the water supply pipe 1-1/4” shorter than this measurement. De-burr by chamfering O.D. and I.D of end of water supply pipe.
- Slide threaded sweat solder adapter onto water supply pipe until shoulder stops on end of pipe. Then sweat-solder the adapter to water supply pipe.
- Measure the distance from the finished wall to the first thread of the sweat solder adapter. If necessary, cut chrome cover tube this length.
- Slide the wall escutcheon over the chrome cover tube and slide both items over water supply pipe. Press wall escutcheon flush against finished wall and tighten set screw with hex wrench (supplied) to secure it in place.
Control Stop Installation Instructions
- Install control stop assembly by threading it onto water supply pipe and tightening with a smooth jawed wrench. Apply thread sealing compound or pipe tape to the male NPT thread on sweat solder adapter only.
- When all stop valves are properly connected to the water supply line and water pressure is available open the control stop using a flathead screwdriver and turning the stop valve adjustment screw counterclockwise.
Flush Valve Installation
- Before attaching the flush valve tailpiece to the control stop, check the O-ring seal and ensure it’s properly positioned in the groove. Also, make sure the locking nut and locking snap ring are in place on the tailpiece. Lubricate the tailpiece o-ring with water and insert flush valve tailpiece into the control stop valve. Tighten the locking nut using a smooth-jawed wrench.
- Loosen the set screws through two small holes on the shroud escutcheon by turning counter-clockwise. Uninstall shroud escutcheon from the valve body by turning it counter-clockwise and lower it from the shroud. Determine the length of vacuum breaker tube required to join the flush valve and fixture spud, and cut if necessary.
- Slide the tube nut, spud nut, slip gasket, rubber gasket, spud escutcheon and shroud escutcheon over the vacuum breaker tube and insert tube into fixture spud. Hand tighten tube nut to valve body and hand tighten spud nut onto fixture spud. Adjust the valve assembly for plumb. Tighten fixture spud nut, vacuum breaker tube nut and locking nut with a wrench.
- Adjust and plumb the valve assembly. Tighten all connections with smooth jawed wrench and turn on water supply at the control stop.
- Lastly, reinstall the shroud escutcheon back onto the shroud by turning it clockwise and tighten both set screws clockwise to secure escutcheon in place . DO NOT cut vacuum breaker tube shorter than 6” below the -C-Lindicator mark, as vacuum breaker must be 6” above the fixture. Consult plumbing Codes & Regulations for specific details.
Battery Installation
- Turn both set screw through the small holes on the side of the valve head counterclockwise with the 3/32” Allen Wrench until they are back into the valve head. Then, remove the valve head by lifting it up.
- As shown, insert 2 AA Alkaline batteries (supplied) into the battery tray as backup batteries.
Wire Harness Connection – Right Side Water Supply
- Connect the connector from the valve head to the connector from the valve body carefully.
- Bundle the connected cable harness up neatly place in the area above the backup battery tray and slowly lower the valve head back on to valve body. Reinstall the valve head back onto the valve body by reversing step 1 in the battery installation instructions.
Wire Harness Connection – Left Side Water Supply
- Connect the connector from the valve head to the connector from the valve body carefully.
- Rotate the valve head to have the sensor lens facing the front.
- Bundle the wire harness neatly and flat across the rechargeable battery and position the connectors in the vacant area shown. Next, slowly lower the valve head back onto the valve body. Reinstall the valve head back onto valve body by reversing step 1 in battery installation instructions.
- Follow right hand installation instructions to install a flush valve with the sensor lens facing the back wall up to the Harness Connection step.
Diaphragm Replacement and Cleaning
-
Turn off control stop using a flathead screwdriver turning clockwise. Afterward, utilize the manual override button to flush water out of the flush valve.
-
Loosen the set screws through two small holes on the shroud escutcheon by turning counter-clockwise. Uninstall the shroud escutcheon from the valve body by turning it counter-clockwise and lowering it from the shroud.
-
Lift the valve head slightly to release the two shrouds. Move the shrouds away from each other at the same time to remove them from the valve body. Use tape or a marker to mark the original position of the locking ring about the valve body.
-
Ensure both the strap wrench and locking ring are completely dry for optimal grip. Use the supplied strap wrench to counter-clockwise loosen the valve head’s locking ring. If the strap wrench is slipping, you may use a large wrench on the flats of the locking ring to loosen it.
Diaphragm Replacement and Cleaning (Cont.) -
5. Remove the existing diaphragm kit from the manifold stem. Thoroughly wash the diaphragm and orifice using water. Install the cleaned diaphragm back into the valve body, and ensure that the orifice is facing the correct orientation. For the correct orifice orientation, Refer to the retrofit installation instruction section. If the issue persists after cleaning, proceed to step 5B. Do not damage or enlarge the orifice. Doing so will result in an incorrect flush rate.
- Remove the existing diaphragm kit from the manifold stem. If the o-rings show signs of wear or damage, replace them with the new ones provided in the diaphragm repair kit. Install a new diaphragm kit (with matching flow rate) into the valve body, and ensure that both orifices are positioned in line with the control stop. Take care to align it properly. Note that unless the Volume Control Ring is missing or broken, there is no need to replace it.
-
Place the valve head with the diaphragm kit back onto the valve body. Ensure that both the strap wrench and locking ring are dry for a better grip. Tighten the locking ring to its original position using the supplied strap wrench by turning it clockwise.
-
Reverse steps 2 & 3 to reinstall both shrouds and shroud escutcheon. Turn the control stop back on by turning counterclockwise using a flathead screwdriver.
Sensor Range Adjustment
To ensure optimal performance in various restroom environments, each ZER-HYD is initially calibrated at the factory. However, in situations where there is low light or high reflectivity, it might be necessary to make adjustments to the calibration distance of the unit. This can be done using a Magic Magnet (P6900-AT-MAG). Follow the steps outlined below to re-calibrate the ZER-HYD using a Magic Magnet (P6900-AT-MAG):
- Stand at the desired calibration distance:
- ~28” from the sensor in a water closet application.
- ~22” from the sensor in a urinal application.
- Place Magic Magnet to the right of the ZER-HYD’s lens within the indicated area. Hold the Magic Magnet in that position until the user LED lights up.
- Maintain the position of the Magic Magnet until the user LED starts blinking. Once the blinking begins, remove the Magic Magnet and allow the user LED to blink 10 times while remaining in the same position. A quick double-blink of the user LED indicates that the calibration process is complete.
- To verify the new calibration distance, step away from the unit for 5 seconds. Then return to the exact position at which it was calibrated and observe the user LED. If the user LED blinks, it indicates that the calibration distance has been successfully calibrated.
Note: To ensure proper functionality, make sure the calibration distance in water closet applications prevents the sensor from detecting the stall door. Verify this by closing the door for 10 seconds, then opening it. If the flush valve doesn’t activate, the calibration distance is suitable. Otherwise, recalibrate to a closer distance using the magnet.
Care and Cleaning Instruction
- Do not use any abrasive or chemical cleaners to clean the flushometer.
- The suggested cleaning of chrome-plated surfaces is simply to clean them with mild soap and water, then dry. Commercial cleaning compounds are never recommended.
- Upon cleaning other areas of the restroom, be sure the sensor lenses are protected from other cleaning chemicals/solvents to prevent potential damage to the sensor and/or electronics.
- Valves used in installations subject to shutdown because of cold and freezing conditions should be maintained in the following manner. After the main supply has been shut off and the water drained from the system, remove the stop valve cap and stop valve internals to allow the water to drain from the flush valve itself.
Dual Flush User Guide (For ZER6000AV-DF Only)
- The Dual Flush model supplies flush volumes of 1.1 and 1.6 gallons per flush. When a user is present for less than 60 seconds, the valve will flush with 1.1 gallons of water. When a user is present for over 60 seconds, the valve consumes 1.6 gallons of water. A user must be present for a minimum of 8 seconds to trigger a flush.
- The Dual Flush model must be paired with a fixture with a flush volume range that includes 1.1 to 1.6 gallons per flush. For a list of recommended bowls, please refer to our website, www.zurn.com, or speak with your local Zurn rep.
Trouble Shooting Guide
Problem | Indicator | Cause | Corrective Action |
---|
The flush valve does not flush.
| No water flushed.| The stop valve is closed| Open stop valve
Sensor flashes 5 times in
quick succession
| Flush cycle did not complete| Contact Customer Service for further instruction
No sensor light
| Batteries not making contact| ****
Remove and reinstall batteries correctly, or replace batteries See Battery installation for reference.
Critically low battery voltage
Sensor flashes once every 5
seconds
| Low battery voltage indication
Sensor flashes every 30
seconds
| Continuous user detection of objects within sensor range| Recalibrate. See the Sensor Range adjustment section for reference.
Sensor flashes rapidly
| Battery Powered:
Batteries installed incorrectly.
| Remove and reinstall batteries correctly. See Battery installation for
reference.
Hardwired:
Backup batteries installed incorrectly
| Remove and reinstall batteries correctly. See Battery installation for reference.
Hardwired:
The backup Battery was not detected.
| Install backup batteries, or reference the courtesy flush & battery detection settings section to turn off backup battery detection.
The sensor detects user, three slow flashes & two quick flashs, but fails to flush upon exiting sensor range
| ****
The user/object still in the sensor field
| Identify and remove any user from
sensor field
Reduce sensor range distance (see Sensor Range Adjustment instructions)
Battery power level too low to activate
flush valve
| Replace batteries. See Battery Installa-Installationrence.
Dirty sensor lens| Clean the sensor lens with warm water and mild soap until
free of debris
Loose or damaged wire harness| Inspect wire harness and connection between
electronics and motor
User not detected; no LED
flashes.
| Sensor range may need to be adjusted| Increase sensor range distance (see
Sensor Range Adjustment instructions)
The flush valve is aimed at an angle.| Rotate the flush valve head to be
perpendicular to the wall. See the Sensor Angle Adjustment section for
adjusting the flush valve head.
The manual override button does
not initiate a flush.
| The stop valve is closed/turned off.| Turn on the stop valve.
MOB does not depress| Contact Customer Service.
Valve does not evacuate
fixture
| ****
Insufficient volume of water to adequately siphon fixture.
| The stop valve is not open enough.| Open the stop valve for the desired
volume of water.
Insufficient volume or pressure at
supply.
| Increase incoming water supply pressure to a minimum of 25psi.
Insufficient volume for installed fixture| Contact Customer Service.
The valve shuts off too quickly or short flushes.
| Damaged or punctured diaphragm.| Install a new diaphragm replacement kit.
(See Diaphragm Replacement and Cleaning Section for replacement instructions)
Enlarged by-pass orifice.| Install new diaphragm replacement. (See Diaphragm
Replacement and Cleaning Section for replacement instructions)
The diaphragm kit is not matched to the
fixture.
| Install a new diaphragm replacement kit. (See Diaphragm Replacement and
Cleaning Section for replacement instructions)
Problem| Indicator| Cause| Corrective Action
---|---|---|---
The valve is flushing too long or not shutting off.
| ****
High water delivery or
continuous flow.
| By-pass orifice is plugged or partially
plugged.
| Examine the by-pass orifice and clean it if necessary being certain not to enlarge the orifice opening. (See Diaphragm Replacement and Cleaning Section for cleaning instructions)
Water splashes out of the fixture.
| ****
Water splashes onto the floor during the flush cycle.
| Supply volume is too high.| Slowly close the control stop to lower the water
pressure.
Mineral accumulation on vortex or
spreader holes of the fixture.
| Remove the mineral buildup.
Flush is not considered quiet.
| ****
Flush is loud.
| Control stop may not be adjusted for quiet operation.| Adjust the control
stop for quiet operation keeping in mind the fixture evacuation requirements.
The fixture may be contributing to the noise.| Check the noise created by the
fixture by placing a cover over the bowl opening to separate valve noise from
bowl noise. If it is determined the fixture is too noisy, consult with the
fixture manufacturer.
The piping system may be a source of noise.| High pressure in the system can
sometimes be controlled by the stop valve. Other sources of noise may be the
absence of air chambers and shock arrestors, loose pipes, improper-sized
pipes, etc. In these cases, the building engineer should be consulted.
Valve leaking near valve head.| Water droplets are seen between the valve head
and the valve body.| The locking ring is not tight.| Tighten the locking ring.
See the Sensor Angle Adjustment section for reference.
The valve flushed with no user
present
| ****
The valve flushed with no user
present
| Highly reflective environment| ****
Re-calibrate sensor range – see Sensor Range Adjustment section
Sensor range set too far; picking up other objects
The flush valve may be configured to exchange the water in the trap-way at
every [24 / 48 / 72] hours after no usage (default is OFF).| See Courtesy
Flush Battery Detection Settings for instructions on changing dipswitch
settings to achieve the desired trap exchange timing.
- Rev. A | Date: 6/4/2024 | C.N. No. 145585 | Prod./Dwg. No. FV845
- Patent zurn.com/patents
- US 1.855.ONE.ZURN CANADA 1.877.892.5216
References
- P65Warnings.ca.gov
- Zurn | Engineered Water Solutions for Plumbing, Drainage
- Zurn | Engineered Water Solutions for Plumbing, Drainage
- Patents | Zurn Industries LLC's products
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>