RFID SecureEntry-CR40 Reader with Access Control User Manual

June 25, 2024
RFID

User Manual
RFID reader with access
control
SecureEntry-CR40

Specifications:

  • Warranty: 1 year
  • RFID Card Supported: 125 kHz
  • Device Type: Access Control RFID Card Reader
  • Interface: Wiegand 26
  • Verification Type: RFID Card
  • Access Control: Yes
  • Voltage: 9~24V DC
  • Ingress protection: IP66
  • Reading Distance: > 3cm
  • Operating current: 25 mA
  • Operating temperature: -40°C~60°C
  • Operating humidity: 10% to 95%
  • Product dimensions: 105 x 20 mm
  • Package dimensions: 103 x 48 x 19 mm
  • Product weight: 180 g
  • Product weight with packaging: 260 g

Set contents:

  • RFID reader with access control
  • Screws and mounting plugs
  • Manual

Features:

  • The RFID reader can be combined with an electric lock, thanks to which we will obtain a device that allows us to manage access to rooms and buildings.
  • The device supports RFID cards with 125 kHz frequencies
  • The access control system has a water-resistant housing with IP66 protection, so it can be installed outdoors.
  • The reader is equipped with a Wiegand 26 interface, which allows it to be connected to a time recorder and transfer data.

Installation

  • Drill 2 holes in the wall for screws (A, C) and one hole for wire (B)
  • Drive the rubber pins into the holes (A, C)
  • Attach the back cover to the wall with 2 screws
  • Insert the wire through the cable hole (B)
  • Attach the device to the back cover

RFID SecureEntry CR40 Reader with Access Control-

Function Table

Reading the card| The LED will turn green and the buzzer will beep, meanwhile, the reader will send a Wiegand signal.
---|---
External LED Control| When the input voltage for the LED is low, the LED will turn green
External buzzer control| When the input voltage for the buzzer is low, the buzzer will make a sound
Wiegand Data Output| The factory default setting is 26 bits.

Wiring Diagram

RFID SecureEntry CR40 Reader with Access Control- fig1

Colour Function Comments
Red Power +DC (9-24V)
Black GND Ground
Green D0 Data 0
White D1 Data 1
Brown LED Green LED control
Yellow Buzzer Buzzer control

(Note: The brown and yellow wires are optional connections.)

Data Signal

Description Reader Typical Time
Pulse Duration 42 μS
Pulse Interval Time 2 mS

The table above shows the waveform of time, pulse width (pulse duration), and interval time (time between pulses) of Wiegand data sent from readers. (Example 1010)