ELATEC RFID TWN4 Palon Square M LF HF Module User Manual
- June 6, 2024
- ELATEC RFID
Table of Contents
ELATEC RFID TWN4 Palon Square M LF HF Module
INTRODUCTION
ABOUT THIS MANUAL
This user manual is intended for the user and enables a safe and appropriate
handling of the product. It gives a general overview, as well as important
technical data and safety information about the product. Before using the
product, the user should read and understand the content of this user manual.
For the sake of better understanding and readability, this user manual might
contain exemplary pictures, drawings and other illustrations. Depending on
your product configuration, these pictures might differ from the actual design
of your product.
The original version of this user manual has been written in English. Wherever
the user manual is available in another language, it is considered as a
translation of the original document for information purposes only. In case of
discrepancy, the original version in English will prevail.
SCOPE OF DELIVERY
COMPONENTS AND ACCESSORIES
Depending on your product configuration, the product can be delivered alone or
with different components and accessories, such as cables or wall holders, as
part of a kit. For more information about the delivered components and
accessories, refer to your delivery note, consult the ELATEC website or
contact ELATEC.
SOFTWARE
The product is delivered ex-works with a specific software version (firmware).
Refer to the label attached to the product to find the software version
installed ex-works.
ELATEC SUPPORT
In case of any technical questions, refer to the ELATEC website
(www.elatec.com) or contact ELATEC technical support
at support-rfid@elatec.com In case of questions
regarding your product order, contact your Sales representative or ELATEC
customer service at: info-rfid@elatec.com
REVISION HISTORY
VERSION | CHANGE DESCRIPTION | EDITION |
---|---|---|
02 | Chapters “Introduction”, “Intended Use”, “Safety Information”, “Mode of |
Operation” and
“Compliance Statements” updated
| 02/2022
01| First edition
(replaces ELATEC TWN4 Palon Square M user manual DocRev2 , dated 03/2021)
| 09/2021
INTENDED USE
TWN4 Palon Square M LF HF is a versatile OEM PCB for integration into third- party products and devices. It supports enhanced interfaces, especially RS-485. The new single PCB module inherits all advantages and tool support of the ELATEC TWN4 family. Although being a general-purpose PCB module, it is optimized for time attendance and access control. The product is intended to be integrated into a host device. Any use other than the intended use described in this section, as well as any failure to comply with the safety information given in this document, is considered improper use. ELATEC excludes any liability in case of improper use or faulty product installation.
SAFETY INFORMATION
Unpacking and installation
- The product contains sensitive electronic components that require particular attention when unpacking and handling the product. Unpack the product carefully and do not touch any sensitive components on the printed circuit board. In case the product is equipped with a cable, do not twist or pull the cable.
- The product is an electronic product whose installation requires specific skills and expertise. The installation of the product should be done by a trained and qualified personnel only. Do not install the product by yourself.
Handling
- Depending on your product configuration, the product might be equipped with one or more light-emitting diodes (LED). Avoid direct eye contact with the blinking or steady light of the light-emitting diodes.
- The product has been designed for a use under specific conditions (refer to the product data sheet). Any use of the product under different conditions might damage the product or alter its reading performance.
- The use of other RFID readers or reader modules in direct vicinity to the product, or in combination with the product might damage the product or alter its reading performance. In case of doubts, contact ELATEC for more information.
- The user is liable for the use of spare parts or accessories other than the ones sold or recommended by ELATEC. ELATEC excludes any liability for damages or injuries resulting from the use of spare parts or accessories other than the ones sold or recommended by ELATEC.
- Like most electronic devices, RFID systems generate electromagnetic waves that can vary in amplitude and frequency. It is generally known and accepted that some RFID devices might potentially interfere with personal medical devices, like pacemakers or hearing aids. Users with a pacemaker or any other medical device should use TWN4 Palon Square M LF HF carefully and refer to the information given by the manufacturer of their medical devices before using TWN4 Palon Square M LF HF or any host device containing TWN4 Palon Square M LF HF.
Maintenance and cleaning
- Any repair or maintenance work should be done by a trained and qualified personnel only.
- Do not try to repair or carry out any maintenance work on the product by yourself.
- Do not allow any repair or maintenance work on the product by an unqualified or unauthorized third party.
- The product does not need any special cleaning.
- Do not use any detergents or other cleaning agents on the product.
Disposal
The product must be disposed of in accordance with the EU directive on
waste electrical and electronic equipment (WEEE) or any applicable local
regulations.
Product modifications
The product has been designed, manufactured and certified as defined by
ELATEC. Any product modification without prior written approval from ELATEC is
prohibited and considered improper use of the product. Unauthorized product
modifications may also result in the loss of product certifications.
If you are unsure about any part of the safety information above, contact ELATEC support. Any failure to comply with the safety information given in this document is considered improper use. ELATEC excludes any liability in case of improper use or faulty product installation.
TECHNICAL DATA
Power supply
9.0 V – 30 V via connector X1; 4.3 V – 5.5 V via micro USB
Current consumption
Operating: typ. 180 mA @12 V; Idle: typ. 50 mA @12 V; Peak typ. 250 mA @12 V
Antennas
The reader module is equipped with the following antennas:
HF antenna (13.56 MHz)
- Dimensions: 62 mm x 62 mm / 2.44 inch x 2.44 inch
- Number of turns: 2
LF antenna (125 kHz)
- Diameter: 20 mm / 0.79 inch
- Number of turns: 234
For more information, refer to the related product data sheet or other technical documents.
MODE OF OPERATION
The mode of operation described in the following chapter is based on a
standard ELATEC RFID reader module equipped with two LEDs. Depending on your
product (number of LEDs, installed firmware, etc.) and in case the product
settings have been modified with the AppBlaster tool, the information below
might differ from your product configuration when in operation. In particular,
the color and sequence of the LEDs on your product might be different.
OPERATING MODE
In order to start operating TWN4 Palon Square M LF HF, it simply has to be
connected directly to a host device.
POWER UP
In case of an external power supply unit is used, the following requirements
must be satisfied:
- Limited power source according to the safety standards listed in the respective declaration(s) of conformity
- Short-circuit current < 8 A Once TWN4 Palon Square M LF HF is connected to the host, it detects the type of communications cable (e.g. USB), with which it is connected to the host.
ENUMERATION
This is only applicable for the USB version: Once the device has been powered
up, it is waiting for completion of the enumeration by the USB host. As long
as the device is not enumerated, it is entering a minimum power consumption
mode, where both LEDs are turned off.
INITIALIZATION
After powering up and enumeration (in USB mode), the device is turning on the
built-in transponder reader logic. The green LED is turned on permanently.
Some RFID reader modules need some kind of initialization, which is performed
in this step. After successful initialization, the device sounds a short
sequence, which consists of a lower tone followed by a higher tone.
NORMAL OPERATION
As soon as the reader module has completed the initialization, it is entering
normal operation. During normal operation, the reader module is searching for
a transponder continuously.
DETECTION OF A TRANSPONDER
If a transponder is detected by the reader module, following actions are
performed:
- Send the ID to the host. By default, the USB device sends by emulating keystrokes of a keyboard.
- Sound a beep.
- Turn off the green LED.
- Blink the red LED for two seconds.
- Turn on the green LED.
Within the two seconds timeout, where the red LED is blinking, the transponder, which just has been recognized will not be accepted again. This prevents the reader module from sending identical IDs more than one time to the host. If during the two seconds timeout of the red LED a different transponder is detected, the complete sequence restarts immediately.
SUSPEND MODE
The USB version of the reader module supports the USB suspend mode. If the USB
host is signaling suspend via the USB bus, the reader module is turning off
most of its power consuming peripherals. During this operation mode, no
detection of transponders is possible and all LEDs are turned off. Once the
host is resuming to normal operation mode, this is also signaled via the USB
bus. Therefore, the reader module will resume to normal operation too.
COMPLIANCE STATEMENTS
EU
TWN4 Palon Square M LF HF is in compliance with the EU directives and
regulations as listed in the respective declaration of conformity.
RF EXPOSURE COMPLIANCE
RF exposure statement (mobile and fixed devices) This device complies with the
RF exposure requirements for mobile and fixed devices. However, the device
shall be used in such a manner that the potential for human contact during
normal operation is minimized.
Micropower scope of use declaration:
TWN4 Palon Square M LF HF supports transmission frequencies of 13.56 MHz and 125 kHz. The user needs to adhere to the following specifications when using the product:
-
The specific provisions listed in the “catalog and the technical specifications for micropower short-range radio transmission equipment” as well as the usage scenarios for the antenna type used, the functions, and the customary use of the control system, regulation, and switches must be complied with;
Transmission power:- 13.56 MHz: ≤ -2.66 dBμA/m (field strength at 10 meters, standard max value)
- 125 kHz: ≤ -14.11dBμA/m (field strength at 10 meters, standard max value)
- Antenna: built-in antenna (cannot be removed)
- Control system, regulation, and switches: The user cannot control, regulate, or switch over the radio transmission function of the antenna.
-
The unauthorized modification of usage scenarios or the conditions of use, expansion of the transmission frequency range, or increase of the transmission power (including installing additional transmission power amplifiers), as well as the unauthorized modification of the transmission antenna are not allowed;
-
The product may not interfere in any way with any legal radio transmitters (stations) and may not offer any shielding from harmful interference;
-
The product must be able to tolerate interference caused by industrial, scientific, and medical (ISM) devices which radiate high frequency energy or other legal interference from radio transmitters (stations);
-
Should the product cause harmful interference on other legal radio transmitters (stations), product use must be discontinued immediately and suitable measures must be taken prior to using the product again in order to eliminate said interference;
-
When using micropower devices inside of an aircraft or radiometric observatories, or when using such devices in meteorological radar stations, satellite ground stations (including measuring and control stations, distance measuring stations, receiving stations, or navigation stations), as well as in radio transmitters (stations) used by the military and electromagnetic environment protections zones at airports, all applicable provisions of the competent authorities as well as statutory provisions, national regulations, and national standards must be complied with;
-
Remote controls of any kind may not be used within 5000 meters of airport runways, measured from the middle of the runway;
-
Ambient conditions such as temperature and voltage when using micropower devices:
- operating voltage of TWN4 Palon Square M LF HF: 4.3 V –5.5 V (charging via micro USB),
- operating temperature: -25 °C – 80 °C,
- storage temperature: -40 °C – 85 °C.
The user must strictly adhere to these temperature and voltage specifications when using the product.
UNITED KINGDOM
TWN4 Palon Square M LF HF complies with the requirements of the UK
legislations and other regulations as listed in the respective UK declaration
of conformity. The importer is responsible for applying the following
information to the packaging of the product:
- the importer company’s details, including the company’s name and a contact address in the United Kingdom.
- UKCA marking
FURTHER STATEMENTS
Should the device be certified and installed in the following countries or
regions, the corresponding statements (see below) must be contained in the
user manual.
APPENDIX
A – TERMS AND ABBREVIATIONS
TERM | EXPLANATION |
---|---|
HF | high frequency |
LED | light-emitting diode |
LF | low frequency |
NFC | near field communication |
PCB | printed circuit board |
RFID | radio frequency identification |
UKCA | UK conformity assessed |
WEEE | Waste of electrical and electronic equipment. |
Refers to Directive 2012/19/EU of the European Parliament and of the Council of the European Union
B – RELEVANT DOCUMENTATION ELATEC documentation
- ELATEC quick start guide
- TWN4 Palon technical handbook
- TWN4 Palon Square M LF HF data sheet
- TWN4 Palon Square M LF HF integration manual
Zeppelinstr. 1 • 82178 Puchheim • Germany
P +49 89 552 9961 0 • F +49 89 552 9961 129 • E-mail: info-rfid@elatec.com
elatec.com
Elatec reserves the right to change any information or data in this document without prior notice. Elatec declines all responsibility for the use of this product with any other specification but the one mentioned above. Any additional requirement for a specific customer application has to be validated by the customer himself at his own responsibility. Where application information is given, it is only advisory and does not form part of the specification. Disclaimer: All names used in this document are registered trademarks of their respective owners. © 2022 ELATEC GmbH – TWN4 Palon Square M LF HF user manual DocRev2 – 02/2022
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>