Specifications

  • Product Name: LED TB Tube Series
  • Product Model: TB-LED
  • Surface-mounted, Type IC, or Type non-IC recessed-mounted
  • With or without a diffuser
  • Not dimmable
  • Max 4 LED Tubes which are manufactured by EarthTronics.
  • Model: LT815CCBEM
  • Max. mounting height: 8.07 ft

Product Usage Instructions

Installation Instructions

  1. Turn the DIP switch on the B side to the ON position.
  2. Combine the adapter and the end cap on the B side.
  3. Disconnect power to the fixture.
  4. Remove existing tubes, and reflector, and remove the lamp housing.
  5. Open the Test Switch hole on the side of the fixture.
  6. Install the external Test Switch.
  7. Connect the AC terminal wire(Black, White, Red) in the Accessory box to the Junction Box.
  8. Install the lamp housing, reflector, and existing tubes.
  9. Install the Emergency LED lamp.
  10. AC & Test Switch terminal male and female are plugged together.

Safety Precautions

  • The product should be installed by a qualified electrician.
  • Switch off the power supply before commencing work, and ensure correct connection before powering on.

FAQ

Q: What should I do if I encounter interference while using the product?

A: The device complies with Part 15 of the FCC Rules and should not cause harmful interference. If interference is encountered, ensure that correct installation procedures have been followed and contact EarthTronics for further assistance.

Q: Can the LED retrofit kit be used in any type of luminaire?

A: The kit is intended to retrofit Target Luminaires with specific characteristics listed in the user manual, including surface mounted, Type IC, or Type non-IC recessed mounted luminaires with or without a diffuser. Ensure compatibility before installation.

Product Features

  • UL certified
  • Full glass housing: No Aging. Yellowing, Bending.

Product Applications

Widely used in residential buildings, offices, shopping malls, supermarkets, hospitals, assembly lines, warehouses, etc. for energy-saving illumination.

PARTS/COMPONENTS INCLUDED IN KIT

  • Installation Instructions
  • Emergency LEO tube x 1 PCS
  • Luminaire Marking Labels
  • Miscellaneous Hardware

Installation Instructions

Please completely comply with these instructions and notes, to ensure that the product is operated in a safe condition.

Safety Precautions

For your and others’ safety, please read the precautions carefully before installation.

  1. The product should be installed by a qualified electrician.
  2. Switch off the power supply before commencing work, and make sure the correct connection is before power on.

INSTALLATION INSTRUCTIONS

  1. Turn the DIP switch on the B side to the “ON” position.
  2. Combine the adapter and the end cap on the B side.
  3. Disconnect power to the fixture;
  4. Remove existing tubes, and reflector, and remove the lamp housing;
  5. Open the Test Switch hole on the side of the fixture;
  6. Install the external Test Switch
  7. Connect the AC terminal wire(Black, White, Red) in the Accessory box to the Junction Box.
  8. Install the lamp housing, reflector, and existing tubes;
  9. Install the Emergency LED lamp;
  10. AC & Test Switch terminal male and female are plugged together;
  11. The AC wire and the Test Switch wire enter the interior of the fixture;
  12. Install the Fixed Clip at the B side,

Wiring Instruction

  • WARNING – Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
  • WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
  • Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components.
  • WARNING -To prevent wiring damage or abrasion, do not expose wiring to the edges of sheet metal or other sharp objects.
  • Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead, installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.
  • FOR RETROFIT KITS CERTIFIED TO CANADIAN REQUIREMENTS THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN UNDER THE APPLICABLE AND APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS.
  • Installers should examine all parts that are not intended to be replaced by the retrofit kit for damage and replace any damaged parts before installation of the retrofit kit.
  • WARNING – Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for the installation of an LED retrofit kit. Check for enclosed wiring and components.
  • The retrofit position is located at the edge of the Target Luminaire which installed Max four LED Tubes.

The kit is intended to retrofit Target Luminaires with the following characteristics:

  1. Surface mounted, Type IC, or Type non-IC recessed mounted.
  2. With or without a diffuser.
  3. Not dimmable.
  4. Max 4 LED Tubes which are manufactured by EarthTronics. Model: LT815CCBEM
  5. The retrofit position is located at the edge of the four LED Tubes.
  6. One single branch circuit as a power supply connection.
  7. Refer to the below table for the Min compartment dimension.
  8. Max. mounting height: 8.07 ft

FCC

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference,
  2. this device must accept any interference received, including interference that may cause undesired operation.