MATRIX MD-BLF-T04LL 200 CFM 3-Speed Portable Evaporative Air Cooler User Guide

June 5, 2024
MATRIX

MATRIX logo

MATRIX MD-BLF-T04LL 200 CFM 3-Speed Portable Evaporative Air

CoolerMATRIX MD-BLF-T04LL 200 CFM 3-Speed Portable Evaporative Air Cooler
product

Thank you for choosing our Evaporative Air Cooler. This user manual will provide you with valuable information necessary for the proper care and maintenance of your new product.
Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new product

FAULT AND MAINTENANCE

MATRIX MD-BLF-T04LL 200 CFM 3-Speed Portable
Evaporative Air Cooler fig 8

A SAFETY INSTRUCTIONS

For your safety concerns, please make sure to follow the instructions above.

  1. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety
  2. Children should be supervised to ensure that they do not play with the appliance
  3. Before any maintenance, make sure the machine is in the “off state, and the power is switched off In order to avoid the electric shock, please connect the grounding socket correctly, and guarantee the connection of the grounding device with the function of automatic protection from faults.
  4. If the supply cord is damaged, it must be replaced by manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  5. Ensure that the fan is switched off from the supply mains before removing the guard.
  6. Unplug the appliance during filling and cleaning.
  7. Do not use any corrosive or solvent detergent for cleaning. It is recommended to use wet cloth to wipe the machine instead of flushing the machine. Please avoid the machine exposed to direct sunlight.
  8. It is strictly prohibited to use this machine in a circumstance with inflammable or explosive gas.

PRODUCT DIAGRAM

MATRIX MD-BLF- T04LL 200 CFM 3-Speed Portable Evaporative Air Cooler fig 1

  1. Control Panel
  2. Carrying Handle
  3. Circular Air Outlet
  4. Power Cord &Plug
  5. Water Level Indicator
  6. Water Tank
  7. Air Filter
  8. Evaporative Media Cartridge (behind the air filter)
  9. Water Tank Lock
  10. Remote Controller

PARTS & ACCESSORIESMATRIX MD-BLF-T04LL 200 CFM 3-Speed Portable
Evaporative Air Cooler fig 2

SPECIFICATIONS

MATRIX MD-BLF-T04LL 200 CFM 3-Speed Portable Evaporative
Air Cooler fig 33

OPERATING INSTRUCTIONS

Filling Water
As shown in figure 1, pull out the tank from the back of the machine,filling water until the
highest water level.
Attention: Please do not exceed the maximum water level of the water tank.

The Usage of lce-box

  1. if you use ice-box for the first time: open the lid, inject water up to the scale, then tighten the lid.
  2. Set aside for 30-40minutes, till the water and ice crystal mix completely.
  3. Put the icebox in the refrigerator’s freezer room to stay for two hours.
  4. Take the icebox out and put it into the air cooler’s ice container in order to cool down the water temperature.
  5. After using it for a long time, the ice crystal turns to jelly, please put it in the refrigerator again. It can be recycled and reused.

CONTROL PANEL

MATRIX MD-BLF-T04LL 200 CFM 3-Speed Portable Evaporative
Air Cooler fig 5

Cool button
Press this button, the “Cool ” indicator will light up and the pump will start to work. The water pump pumps the water in the water tank to the top of the cooling pad, and the water flows through the cooling pad back to the water tank. The hot air go through the cooling pad and exchanges heat with the cold water, and converts into the damp and cold air, and then the damp and cold air is blown out by the fan. Press this button again to stop the cooling function.
Note : It is forbidden to use the cooling function when there is no water or water shortage. Do not use the cooling function for more than 12 hours, otherwise, it will affect the service life of the pump.

Swing button
Press this button, the “Swing” indicator will light up, the machine’s air outlet will sweep left and right, and the sweep angle is 40 degrees; touch the button again to turn off oscillation.

Speed button
Press this button to switch the wind speed in turn: low speed, medium speed, high speed.
Mode button
Press this button to switch modes in sequence: normal wind mode “Nor.” natural wind mode “Nat”, sleep mode “Sleep”, the corresponding indicator will light up.
Normal: A continuous wind that can be adjusted to low, medium and high speed
Natural : Natural setting provides a soft and comfortable environment with a selection of low, medium and high speed.
Sleep : When the “Speed” Mode is at high level, the sleep function will run at the high-speed natural wind for 30 mins, then switch to the medium- speed natural wind for 30 mins, and then keep running at low-speed natural wind.
When the “Speed” Mode is at a medium level, the sleep function will run at the medium-speed natural wind for 30 mins, then switch to low-speed natural wind and keep running at low-speed natural wind. When the “Speed” Mode is at low level, the sleep function will keep running at low-speed natural wind.

Timer button
Press Timer” button to perform timing operations on the machine. the time that can be set is 1,2, 4, and 8 hours. Each time you press the “Timer button, the corresponding time indicator will light up. When set to “8h”, press the “Timer button again to cancel the timing function

On/off button
After plugging in the power plug, press the “On/Off button to turn on the unit and the unit runs at “Low speed and “Nor.” wind. The indicator lights will be on.
Note : This machine has a memory function, each time it is tumed on, it will automatically return to the settings of last time.
Auto Lights Off
If there is no operation after 1 minute, the lights (except swing and cool lights) on the control panel will automatically turn off. And press any button to turn on the lights.

REMOTE CONTROL

  • ON/OFF:
    Press this button to open the air cooler.
    Press this button at any state to stop the operation.

  • SPEED
    Press to change the wind speed into Low / Mid / High.

  • MODE
    Press to change the wind type into Natural/ Sleep /
    Normal Mode.

  • TIMER:
    Press to set timing system. The timer range is from 1h-8h.

  • sWING:
    Press to control the left-right swing.
    Press again to stop swinging.

  • coOL /HUM:
    Press to open or close the cooling system.MATRIX MD-BLF-T04LL 200 CFM
3-Speed Portable Evaporative Air Cooler fig 7

The remote control uses on button cell battery, type CR2025(3V). To remove the battery carriage use your thumb to squeeze the release tab to the right and then pull the carriage Out. Place the battery into the carriage and slide the carriage back into the remote.
NOTE:
Follow battery disposal instruction on battery packaging, or contact your local safety council for safely disposal of batteries.

Before using the remote control, you must remove the insulating film.

  1. All functions performed with remote control work identically to the fan control panel.
  2. Aim the remote control at the fan control panel to operate the fan.

CLEANING / MAINTENANCE INSTRUCTIONS

Warm prompt
After long-time operation, dust accumulation on the pre-fiters and the wet curtain would affect the airflow and air purify. Please clean the machine regularly.

  1. Clean pre-filter
    Turn off the power, loose the screws, then pull out the pre-filter, clean it with soft brush and mild detergent, rinse by water and dry in the sunshine.

  2. Clean wet curtain
    Turn off the power, loose the screws in the back-cover plate, take out the back-cover plate. Lose the plastic nuts on the wet curtain, the side of the wet pad can be removed. clean it with a soft brush and mild detergent, rinse by water and dry under the sunshine, then install back to the machine.If the dirt is hard to remove after Long-term usage, please change a new wet curtain

  3. Clean the surface
    Turn off the power, clean it with mild detergent and soft cloth. Notice: control panel shall not be touched by water.

  4. Clean water tank
    Turn the inner lock of the water pump to the unlocked position, carefully pull out the water pump (with the water pipe on it). Be careful and do not damage the water pump or water pipe. Pull out the water tank completely and clean the water tank.MATRIX MD-BLF-T04LL 200 CFM 3-Speed Portable Evaporative Air