EarthTronics 4 Inch LED Commercial Downlight Instructions
- June 27, 2024
- EarthTronics
Table of Contents
INSTRU CTIONS
Field Adjustable Performance Downlight
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE
REFERENCE.
This fixtures must be wired in accordance with the National Electrical Code
and all applicable local codes. Proper grounding is required for safety. THIS
PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE
BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND
THE HAZARDS INVOLVED.
WARNINGS:
-
Risk of electrical shock. Disconnect power at fuse or circuit breaker before installing or servicing.
-
To prevent early lamp failure, lamp should only be installed in operating environments ranging between-30 and +40 (-22°F and+104°F).
-
No user serviceable parts inside. To avoid electrical shock do not disassemble product.
-
WARNING- Risk of fire or electric shock, LED Retrofit Kit installation requires knowledge of luminaires electrical systems.
If not qualified, do not attempt installation. Contact a qualified electrician. -
WARNING- Risk of fire or electric shock, Install this kit only in luminaires that have the construction features and min dimensions shown in the Template and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
-
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation
-
WARNING- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
-
Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals, Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.
-
THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. Product must be installed by a qualified electrician in accordance with the applicable and appropriate electrical codes. The installation guide does not supersede local national regulations for electrical installation
-
Caution – risk of fire. Consult a qualified electrician to ensure correct branch circuit conductor.
WHAT’S IN THE BOX
TOOLS NEEDED
This LED Recessed Kit requires very few tools for installation. A screwdriver
and a pair of wirecutters will help to install.
OPTIONAL ACCESSORIES
Goof Ring
8-10 GR
for extending from 8-1/4″ to 10-1/2″ Maximum Ceiling Cutout 9”
10-12 GR
for extending from 10-1/4″ to 12-1/2” Maximum Ceiling Cutout 10-15/16″
12-14 GR
for extending from 11-1/2″ to 14-3/16″ Maximum Ceiling Cutout 12-3/8″
T-Plate
New construction or remodel plate fr
T-grid ceilings
SJ-Plate
New construction plate for Stud/Jois
Accessories Order Code
11421 CDL PLATE FOR STUD/JOIST
11422 CDL PLATE FOR T-GRID CEILING
11423 CDL 6″ GOOF RING
11424 CDL 8″ GOOF RING
11425 CDL 9.5″ GOOF RING
INSTRUCTIONS
Field Adjustable Performance Downlight
INSTALLATION WITH EXISTING FRAME
-
Shut power OFF to the fixture.
-
Remove the old housing for lamp.(Fig.1)
-
Attach the carabiner safety clip to the existing fixture housing.(Fig.2)
-
Remove junction box faceplate. Disconnect all wires to the ballast and remove ballast from J-Box. Remove appropriate round knock out and attach the fixture conduit whip into knock out. Connect incoming power (White to White, Black to Black, Green to Green/Ground). For 0-10V dimming circuits, pink(or grey) to pink , Purple to Purple. Reattach J-Box faceplate.(Fig.3)
-
Adjust the fixture power to desired lumen output by sliding the black selector switch. Adjust the color temperature to desired one, by sliding the red selector switch.(Fig.4)
-
Install the downlight by lifting both retention tabs upward. (Fig.5)
-
Push until the trim sits flush against the ceiling. (Fig.6)
-
Restore power at the source and the installation is complete.
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
INSTALLATION WITHOUT EXISTING FRAME
-
Make sure the POWER IS TURNED OFF at the source to the location in which you are installing the product.
-
Use template inside box to cut hole in ceiling. (Fig. 7)
-
Select desired lumen output and CCT. (Fig. 8)
INSTALLATION WITHOUT EXISTING FRAME (contd) -
Insert lamp conduit into a preinstalled J-box (not provided) and wire to the power source (black to hot, white to neutral, green to ground).For 0-10V dimming circuits, connect grey to grey and purple to purple. Close the J-box securely. Install the downlight by lifting both retention tabs upward. (Fig.9)
-
Push until the trim sits flush against the ceiling. (Fig. 10)