Specifications

General Specifications

  • Counts: 6000
  • True RMS: Yes
  • Display: 3 kinds

Mechanical Specifications

  • AC Voltage Range: 750V
  • DC Voltage Range: 1000V
  • Frequency Range: 10V1~100KHz

Environmental Specifications

  • Operating Temperature: Not specified
  • Storage Temperature: Not specified
  • Relative Humidity: Not specified

Electrical Specifications

  • AC Current Range: 6000A
  • DC Current Range: 6000A

Product Usage Instructions

Instrument Overview
This digital multimeter offers various functions including LED display, auto/manual range selection, capacitance test, diode test, continuity test, duty cycle test, and more. It is capable of measuring both sinusoidal and nonsinusoidal AC waveforms accurately.

Function Buttons

  • Short press to switch functions, long press for flashlight.
  • Change range by the short press, and enter relative mode with a long push.
  • Press to switch MAX/MIN test; long press to exit MAX/MIN mode.
  • Hold the current reading with a single push; push again to resume normal operation.
  • Long press beyond 2 seconds to toggle the flashlight on/off.

Rotary Button
The rotary button allows you to select different measurement modes such as AC/DC voltage, frequency, resistance, continuity, diode test, capacitance, NCV, DC/AC, and more. Refer to the manual for specific ranges and indications.

Frequently Asked Questions

Q: What is the warranty on this product?

A: Customers enjoy a one-year warranty from the date of purchase. Please refer to the warranty terms for details.

Q: What does the NCV feature do?

A: The NCV feature indicates non contact voltage detection. Please follow safety guidelines when using this function.

Q: How do I replace the batteries or fuses?

A: Refer to the maintenance section in the manual for detailed instructions on replacing batteries and fuses.

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Customers enjoy a one-year warranty from the date of purchase. This warranty does not cover fuses, disposable batteries, damage from misuse accident, neglect, alteration, contamination, or abnormal conditions of operation or handling, including failures caused by use outside of the product’s specifications, or normal wear and tear of mechanical components.

Introduction
This product is a 6000 counts true RMS auto-ranging digital multimeter with 3 kinds of display.

Safety Information

To avoid possible electrical shock, fire, or personal injury, please read all safety information before you use the product. Please use the product only as specified, or the protection supplied by the product can be compromised.

  • Examine the case before you use the product. Look for cracks or missing plastic. Carefully look at the insulation around the terminals.
  • The measurement must be made with correct input terminals and functions and within the allowable measuring range.
  • Do not use the product around explosive gas, vapor, or in damp or wet environments.
  • Keep fingers behind the finger guards on the probes.
  • When the product has already been connected to the line being measured, do NOT touch the input terminal that is not in service.
  • Disconnect the test leads from the circuit before changing the mode.
  • When the voltage to be measured exceeds 36V DC or 25V AC, the operator shall be careful enough to avoid electric shock.
  • Misuse of mode or range can lead to hazards, be cautious. “0L” will be shown on the display when the input is out of range.
  • Low level of a battery will result in incorrect readings. Change the batteries when battery level is low. Do not make measurements when the battery door is not properly placed.

Instrument Overview

LED Display

Tektronix-6000-Digital-Multimeter-Fig- \(2\) Tektronix-6000-Digital-Multimeter-Fig- \(3\)

Function Buttons

Tektronix-6000-Digital-Multimeter-Fig- \(4\)

①| Short press to switch among functions. Long press to turn on/off the flashlight.
---|---
②| Short press to change range.

Push for more than 2 seconds to enter the relative mode. The product will store the present reading as a reference for subsequent readings. The display is zeroed, and the stored reading is subtracted from all subsequent readings. Long- push again to exit the relative mode.

③| Press this button to switch the MAX/MIN test. Long press 2 seconds to quit MAX/MIN mode.
④| Push once to hold the current reading on the display; push again to continue normal operation. Long press beyond 2 seconds to turn on the flashlight, and long press again to turn off the flashlight.

Rotary Button

Tektronix-6000-Digital-Multimeter-Fig- \(6\) Tektronix-6000-Digital-Multimeter-Fig- \(7\)

Input Terminals

A Input    terminal    for    AC/DC measurement(≤10.00A)
μA/mA Input    terminal    for    AC/DC measurement(≤600.0mA)
COM Common    (return)    terminal for all measurements.
Input terminal for the measurements of 1. Diode

2. Continuity

3. AC/DC voltage

4.  Resistance

5.  Temperature

6.  Capacitance

Measurements Instruction

Measure AC/DC Voltage

  1. Connect the black test lead to the COM Terminal and the red lead to the Terminal.
  2. To measure voltage under 600.0mV, turn the rotary to . To measure a voltage higher than 600.0mV, turn the rotary to . Press SELECT to change the AC/DC voltage test mode.
  3. Touch the probes to the correct test points of the circuit.
  4. Read the measured voltage on the screen.
    • Do not measure voltage that exceeds the extremes as indicated in the Specifications.
    • Do not touch high-voltage circuits during measurements.

Measure AC/DC Current

  1. Connect the black test lead to the COM Terminal and the red lead to the A or μA /mA Terminal (choose based on the value of the current to be measured).
  2. Turn the rotary to , or .
  3. Break the circuit path to be measured, connect the test leads across the break and apply power.
  4. Read the measured current on the display.
    • Do not measure current that exceeds the extremes as indicated in the Specifications.
    • Use the A mA Terminal when you are measuring an unknown current, then select the terminal and range according to the display value.
    • Do not input voltage at this setting.

Measure Resistance

  1. Connect the black test lead to the COM Terminal and the test lead to the Terminal.
  2. Turn the rotary to , press “SELECT” to the Resistance Mode. The screen will show “0L”.
  3. Touch the probes to the desired test points of the circuit to measure the resistance.
  4. Read the measured resistance on the display.
    • Disconnect circuit power and discharge all capacitors before you test resistance.
    • Do not input voltage at this setting.

Test Diodes and Continuity

  1. Connect the black test lead to the COM Terminal and the red lead to the Terminal.
  2. Turn the rotary to , press “SELECT” to the continuity mode.
  3. To test continuity, touch the probes to the desired test points of the circuit. The built-in beeper will beep when there is a short circuit.
  4. To test diodes, connect the red probe to the anode side and the black probe to the cathode side of the diode being tested. Then read the forward bias voltage value on the display. If the polarity of the test leads is reversed with diode polarity or the diode is broken, the display reading shows “0L”.
    • Do not input voltage at this setting.
    • Disconnect the circuit power and discharge all capacitors before you test the diode.

Measure Capacitance

  1. Connect the black test lead to the COM Terminal and the red lead to the Terminal.
  2. Turn the rotary to , press “SELECT” to the capacitance mode.
  3. Connect the red probe to the anode side and the black probe to the cathode side of the diode being tested.
  4. Read the measured capacitance value on the display once the reading is stabilized.
    • Disconnect the circuit power and discharge all capacitors before you test the diode.

Measure Frequency and Duty Cycle

  1. Connect the black test lead to the COM Terminal and the red lead to the Terminal.
  2. Turn the rotary switch to , press SELECT to frequency test function ( ≥ 10V , 1~100KHz), ); or turn the rotary switch to , press SELECT to frequency test function (≤10V, 1~10MHz).
  3. If the frequency is between 100kHz and 10MHz, press SELECT to enter the AC mV position. Touch the probes to the desired test points, and now the vice display will show frequency; Then press the SELECT again, and the main display will show frequency and the vice display will show the duty cycle.

Measure Temperature

  1. Connect the black test lead to the COM Terminal and the red lead to the Terminal.
  2. Turn the rotary to , press “SELECT” to the temperature Mode; Now the main display will show Celsius and the vice display will show Fahrenheit.
  3. Touch the probes to the desired test points.
  4. Read the measured temperature on the display.
    • Do not input voltage at this setting.

Test NCV

  1. Turn the rotary to the NCV position, and press “SELECT” to the temperature Mode.
  2. Hold the product and move it around, the built-in beeper will beep when the inner sensor detects AC voltage nearby. The stronger the voltage is, the quicker the beeper beeps.

Maintenance

Beyond replacing batteries and fuses, do not attempt to repair or service the product unless you are qualified to do so and have the relevant calibration, performance test, and service instructions.

Clean the Product
Wipe the product with a damp cloth and mild detergent. Do not use abrasives or solvents. Dirt or moisture in the terminals can affect readings.

  • Remove the input signals before you clean the product.

Replace the Batteries
When “ ” is shown on the display, batteries shall be replaced as below:

  1. Remove the test leads and turn off the product before replacing the batteries.
  2. Loosen the screw on the battery door and remove the battery door.
  3. Replace the used batteries with new batteries of the same type.
  4. Place the battery door back and fasten the screw.

Replace the fuses
When a fuse is blown or does not work properly, it shall be replaced as below:

  1. Remove the test leads and turn off the product before replacing the fuse.
  2. Loosen the four screws on the back cover and the screw on the battery door, then remove the battery door and the back cover.
  3. Replace the fuse with a new fuse of the same type.
  4. Place the back cover and the battery door back and fasten the screws.

Specifications

General Specifications

Display(LCD)| 6000 Counts
Ranging| Auto/Manual
Material| ABS+TPE
Update Rate| 3 Times/Second
Ture RMS| √
Data Hold| √
Backlight| √
Low Battery Indication| √
Auto Power Off| √
Mechanical Specifications
Dimension| 1477637mm
Weight| 191g(without batteries)
Battery Type| 1.5V AAA Battery * 3
Warranty| One year
Environmental Specifications
Operating| Temperature| 0~40℃
Humidity| <75%
Storage| Temperature| -20~60℃
Humidity| <80%

Electrical Specifications

Function Range Resolution Accuracy


DC Voltage (V)

| 6.000V| 0.001V| ****




±(0.5%+3)

60.00V| 0.01V
600.0V| 0.1V
1000V| 1V
DC Voltage (mV)| 60.00mV| 0.01mV
600.0mV| 0.1mV



AC Voltage (V)

| 6.000V| 0.001V| ****




±(1.0%+3)

60.00V| 0.01V
600.0V| 0.1V
750.0V| 0.1V
AC Voltage (mV)| 60.00mV| 0.01mV
600.0mV| 0.1mV
*Frequency response of ACV: 40Hz-1kHz
DC Current (A)| 6.000A| 0.001A| ±(1.0%+3)
---|---|---|---
10.00A| 0.01A
DC Current (mA/μA)| 60.00mA| 0.01mA
600.0mA| 0.1mA
600.0μA| 0.1μA
6000μA| 1μA
AC Current (A)| 6.000A| 0.001A| ****




±(1.2%+3)

10.00A| 0.01A
AC Current (μA/mA)| 60.00mA| 0.01mA
600.0mA| 0.1mA
600.0μA| 0.1μA
6000μA| 1μA
Frequency response of AC Current: 40Hz-1kHz
Resistance| 600.0Ω| 0.1Ω| ±(0.5%+3)
---|---|---|---
6.000kΩ| 0.001kΩ
60.00kΩ| 0.01kΩ
600.0kΩ| 0.1kΩ
6.000MΩ| 0.001MΩ| ±(1.5%+3)
60.00MΩ| 0.01MΩ| ±(3.0%+5)








Capacitance

| 6.000nF| 0.001nF| ±(5.0%+20)
60.00nF| 0.01nF| ****




±(2.0%+5)

600.0nF| 0.1nF
6.000μF| 0.001μF
60.00μF| 0.01μF
600.0μF| 0.1μF
6.000mF| 0.001mF| ****

±(5.0%+5)

60.00mF| 0.01mF
Frequency (Measures only to 100kHz under the ACV setting)| 6.000Hz| 0.001Hz| ±(0.1%+2)
---|---|---|---
60.00Hz| 0.01Hz
600.0Hz| 0.1Hz
60.00kHz| 0.01kHz
600.0kHz| 0.1kHz
6.000MHz| 0.001MHz
10.00MHz| 0.01MHz
Duty cycle| 1%~99%| 0.1%| ±(0.1%+2)
Temperature| (-20~1000)℃| 1℃| ±(2.5%+5)
(-4~1832)℉| 1℉
Diode| √
Continuity| √
NCV| √

All rights reserved. Specifications are subject to change without notice.