DINSTAR DPA SIP Paging Gateway Installation Guide

June 24, 2024
DINSTAR

DINSTAR DPA SIP Paging Gateway

DINSTAR-DPA-SIP-Paging-Gateway-product

Specifications

  • DPA Device Dimension(LWH): 130.63085mm

Front Panel

  • Ethernet interface: Standard RJ45 interface, 10/100M adaptive
  • Camera network interface: External webcam can be connected for video calls
  • Network status indication: No flash: no network connection, Slow flash: normal network connection, Fast flash: SIP account registered successfully
  • External audio signal input: Connect external background sound source
  • External recorder connection: Output mixed signal of intercom sides
  • Volume control: Change ring tone volume, control volume during calls
  • Restore default configuration: Long press button
  • Power indicator

Rear Panel

  • Various ports including USB, microphone input, short circuit switch output, power socket, audio output, etc.
  • Grounding terminal: Ground in case of sound interference
  • USB port: For connecting USB devices

Product Usage Instructions

Installation

Preparations
Drill four holes on the wall with a spacing of 60121 mm for frame installation. Insert plastic expansion tubes and use KA430 screws to mount the device securely.

Obtaining the device IP address
After powering on the device, it will obtain an IP address through DHCP by default. Press the speed dial key for ten seconds  to hear the IP address announced by the device (speaker connection required).

DPA Configuration

Log in the Device Web GUI
Access the device by entering the IP address (e.g., http://172.28.4.131) in a browser. Log in using the default credentials: admin (username) and admin (password).

FAQ

Q: How can I reset the device to its default configuration?
A: Long press the reset button on the front panel to restore the default configuration.

DPA Quick Installation Guide

Shenzhen Dinstar Co.,Ltd.
Tel: +86 755 2645 6664
Fax: +86 755 2645 6659
Email: sales@dinstar.com, support@dinstar.com
Website: www.dinstar.com

DPA Quick Installation Guide

Packing List

DINSTAR-DPA-SIP-Paging-Gateway- \(1\)

Physical Specifications

DPA Device Dimension(LWH) 130.63085mm

Front Panel

DINSTAR-DPA-SIP-Paging-Gateway- \(2\)

Number Description
1 Ethernet interface: Standard RJ45 interface, 10/100M adaptive, it is

recommended to use category five or super category five network cable
2| Camera network interface: external webcam can be connected to realize video call
3| Network status indication. No flash: no network connection. Slow flash: the network connection is normal. Fast flash: the SIP account has been registered successfully
4| External audio signal input, external background sound source can be connected
5| It can be connected to an external recorder to output the mixed signal of both sides of the intercom
6/8| Increase or decrease the volume. You can hear the change of ring tone in idle time. You can directly control the volume during a call
7| Long press to restore the default configuration of the device
9| Power indicator

Rear Panel

DINSTAR-DPA-SIP-Paging-Gateway- \(3\)

3 Microphone input port
4 Short circuit switch output interface (normal open)
5 External LED indication interface
6 RS485 for PTZ/camera control
7 Power socket, DC12V-24V
8 DC12V/24V output interface
9 Speed dial key interface
10 The external switch can be used to directly control the short-circuit

output interface or the input interface of other security equipment

11| Audio output port, can also be externally connected to the power amplifier
12| The external passive speaker interface can be externally connected to a passive speaker. Maximum output power 36W (corresponding to DC24V DC input)

Installation

Preparations

  1. Check the following contents
    • Grounding line x 1
    • Slotted screwdriver x 1
    • KA4 X30 mm screws x 5
    • 6×30mm expansion tube×5
    • Phoenix terminal ×3
  2. Tools that may be required
    • Screwdriver (Ph2 or Ph3), hammer, RJ45 crimper Electric impact drill with a 6mm drill bit

Steps
Drill four holes on the wall with a spacing of 60121 mm for the frame installation, then insert a plastic expansion tube, and next use KA430 screws to tighten the device on the wall, as shown in the figure below.

DINSTAR-DPA-SIP-Paging-Gateway- \(4\)

Obtaining the device IP address

After the device is powered on. By default, the device will get the IP address through DHCP. Press the speed dial key for ten seconds, the DPA will voice broadcast the IP address obtained by default DHCP mode. ( Need to connect speaker)

DPA Configuration

Log in the Device Web GUI
Access the device by entering the device IP (e.g. http://172.28.4.131) through the browser, and the device login interface will open after logging in. The default user name of the interface is admin and the password is admin. DINSTAR-DPA-SIP-Paging-Gateway- \(5\)

Add the SIP account
Configure the SIP account status, register name, username, password, and SIP server IP and port by assigning the SIP account on the server side respectively, and finally click the submit button. DINSTAR-DPA-SIP-Paging-
Gateway- \(6\)

Set DPA Parameters

  1. Set up speed dial
    Click “Door Phone->Call Feature”, users can set up to three numbers for the daytime call button. If the first number is not connected, the device will automatically dial the other numbers and then make call attempts in a circular manner; and also can set up one call button for the nighttime call button, and the device will automatically select this number if the current time is night. DINSTAR-DPA-SIP-Paging-Gateway- \(7\)

  2. Configure the short circuit output switch
    Click “Door Phone->Door Lock” to set the switch mode, there are two operating modes, monostable and bistable, and the switch closing time in monostable mode can be set. DINSTAR-DPA-SIP-Paging-Gateway- \(8\)

  3. Control the short circuit output switch through DTMF
    Click “Door Phone->Access” to set the open door by DTMF code, it can be controlled by the short circuit output switch through DTMF signal. DINSTAR-
DPA-SIP-Paging-Gateway- \(9\)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals