UNI-T UT-P4100A ACDC Current Probe Instruction Manual

June 21, 2024
UNI-T

UT-P4100A ACDC Current Probe

“`html

Product Specifications

  • Type: UT-P4100A (100A/600kHz), UT-P4100B
    (100A/2MHz)

  • Max Current: 100A DC+Pk

  • Max RMS Value: 70.7 Arms

  • Bandwidth (-3dB): 600kHz (UT-P4100A), 2MHz
    (UT-P4100B)

  • Range: 100A or 10A

  • Current Transfer Ratio: 0.01V/A or 0.1V/A

Product Usage Instructions

Warnings and Safety Notices

  • Warning: To avoid short circuits and
    accidents, do not exceed 600VAC during testing.

  • Attention:

    • Protect the probe from sudden temperature changes or impacts to
      prevent damage.

    • Avoid using the probe in dusty or wet environments.

    • Handle the probe with care to prevent malfunction.

Operation Guidelines

  • Power Switch: ON for power on, OFF for power off.

  • Power Indicator: Green light indicates power on.

  • Battery Low Voltage Indicator: Red light indicates low battery
    voltage (<6.5V).

  • Range Switch: Press to switch between High (100A) and Low (10A)
    ranges.

  • Auto Zero Button: Perform zero degaussing for accurate
    measurements.

Frequently Asked Questions (FAQ)

Q: What should I do if the battery voltage is low?

A: If the battery voltage is below 6.5V,
replace the battery with a 9V alkaline battery for longer
usage.

Q: Can the probe be used on naked conductors?

A: No, the probe is not designed for use on
naked conductors to prevent accidents and injuries.

“`

Low Frequency ACDC Current Probe
UT-P4100A (100A/600kHz) UT-P4100B (100A/2MHz)
www.uni-trend.com

Preface
First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention points, etc. Before use, please read the instructions carefully and use correctly.

Manual annotation will use the following symbols to distinguish.

This symbol means it is harmful to the machine and human body; you must strictlyfollowthe instruction manualtooperate.

Warning

In the case of wrong operation, the user risk injury. The content under this mark records the relevant matters needing attention to avoid such dangers.

The user may suffer minor injuries and material damage with the wrong Attention operation. To avoid such situation, the matters under this mark need attention.

Note This symbolizes important note about how to use the machine.

Warning
To avoid short out and deadly accident, the circuit under test should not surpass 600VAC This probe is not designed for naked conductor. Do not touch the conductor under test and the transducer probe during measuring. When the oscilloscope is connected to other test terminal, please be careful for these points:
Please use the fundamental insulation equipment with fitful voltage range and pollution rate while the probe’s test terminal is connected to the other terminals.
Please do not surpass the safe voltage range if the fundamental insulation of the test terminal cannot be met.
Please operate under correct guidance about electric safety. There could be deadly electric shock if the device is damp or the users’ hand is wet.
2

Attention
The probe consists of precision components such as Magnetic core and Hall sensor, which could be possibly damaged because of the sudden temperature change or external force impact. Please be careful for vibration or impact.
The product is neither waterproof nor dustproof; please do not operate in the environment filled with dust and water.
The probe’s upper and lower contact surfaces is made by precise polishing process. Please protect this part or the probe could be malfunction.
Note When the battery voltage is lower than 6.5V, the probe will indicate a low voltage alert, please
change the battery. You can use a 9V alkaline battery for longer time.

UT-P4100A/B Brief Summary

Type
UT-P4100A UT-P4100B

Max current (DC+Pk)

Max RMS value

Band width (-3dB)

Range

Current transfer ratio

100A 100A

70.7 Arms

600kHz

70.7 Arms

2MHz

100A 10A 100A 10A

0.01V/A 0.1V/A 0.01V/A 0.1V/A

3

Catalog
UT-P4100A/B Brief Summary ……………………………………………………………….. 3 Catalog ………………………………………………………………………………………………… 4 1. Summary………………………………………………………………………………………… 5 2. Introduction about probes and accessories ………………………………………….. 5 3. Electronic Characteristics …………………………………………………………………. 7 4. Operating instruction ……………………………………………………………………….. 9 5. Mechanic Characteristics………………………………………………………………… 10 6. Environment characteristics ……………………………………………………………. 10 7. Maintenance………………………………………………………………………………….. 11 8. Troubleshoot …………………………………………………………………………………. 11 9. Packing List ………………………………………………………………………………….. 12
4

1. Summary
UT-P4100A/B is a kind of current probe that can measure both DC and AC current up to 100A (70.7Arms). The band width of UT-P4100A is 600 kHz (-3dB), and the band width of UT-P4100B is 2MHz (-3dB).UT-P4100 series provide two range option of 10A and 100A, the users may choose the correct range according to the current value. The auto zero function make it easy for the users to operate, and it also has power and low voltage indicator as well as overload sound alert. The probe can be powered by battery or external power supply, which makes the measurement a lot more convenient. With standard BNC output port, the probe can connect to any oscilloscope, and it can also connect to multimeter with BNC-banana plug. The UT-P4100 series is usually used in power supply, motor drive and power supply.
2.Introduction about probes and accessories
Probe
5

Power Switch: ON: Power on and probe work; OFF: Power off and probe do not work.
Power indicator: When the power switch is on, the indicator is lighted green. Battery Low Voltage Indicator: when the voltage of the battery is lower than 6.5V, the power
indicator will light red, reminding the users to change battery. Range Switch: press the button switch to change between H and L Range. Range Indicator: indicating the current Range choice. H level: 100A; L level: 10A. Auto Zero button: to make accurate measurement, users need to do zero degaussing before
measuring to avoid the influence of environment factors like earth magnetic field and temperature shift. Auto Zero Indicator: when Auto Zero, the indicator is lighted on and in green and will be turned off when the Auto Zero is finished. Clamp: the clamp used for current measurement; the max diameter for the cable is 12mm. External Power Supply Plug: powered by external DC supply. Battery Box: standard 9V alkaline battery is used. Please turn off the switch and disconnect from the conductor under test & oscilloscope when changing battery.
Accessories
Output Cable: 1 meter
Power Supply AdaptorDC12V/1.2A
6

3.Electronic Characteristics

Test Condition: 23, 60%RH, cable under test get through the test center, load resistance 1M

Range level

L

H

Current range

50mA~10A Peak

1A~100A Peak

Attenuation accuracy Typical DC precision

Band-width (-3dB)

UT-P4100A UT-P4100B

Max current VS frequency characteristics curve
Phase shift

0.1V/A

0.01V/A

3%±50mA

500mA~40A Peak4%±50mA 40A~100A Peak±15% Maximum

DC-600kHz Refer to the typical Amplitude frequency

characteristic (Figure 1)

DC-2MHz Refer to the typical Amplitude frequency

characteristic (Figure 2)

Figure 3

DC65Hz<1.5°

DC65Hz<1°

Typical DC linearity

The typical DC linearity at H level(0.01V/A), Figure 4

Rise time

UT-P4100A UT-P4100B

583ns 175ns

Max operation current

Please refer to voltage and current rating table

Max operation voltage

Please refer to voltage and current rating table

Max floating voltage

Please refer to voltage and current rating table

Operating voltage RMS

CATI 600V CATII 600V CATIII 300V

Common mode voltage RMS

CATI 600V CATII 600V CATIII 300V

Typical battery type and life. Low power indication Overload indication

9V alkaline layer-built battery/ 15H
When battery voltage is lower than 6.5V, battery indicator will turned red and alert.
When the current under test surpasses the range, the buzzer will buzz

Voltage and current rating table

Parameter

Max operating current (A) H(0.01V/A) L(0.1V/A)

DC

100

10

DC+AC peak value

100

10

Max operating voltage (V)
600
600

Max floating voltage(V)
600
600

7

AC peak value

100

AC peak to peak value

200

RMS CAT III

70.7

RMS CAT II

70.7

RMS CAT I

70.7

10

600

600

20

1200

– –

7.07

300

300

7.07

600

600

7.07

600

600

Figure 1 UT-P4100A Typical Gain VS Frequency curve Figure 2 UT-P4100B Typical Gain VS Frequency curve
8

Figure 3 Max current VS Frequency curve
Figure 4 Typical DC linearity (0.01V/A level)
4.Operating instruction
Set the coupling mode of the oscilloscope to DC and the input impedance to 1M; To make it easy to read, users can set the display unit of the oscilloscope from voltage to current display. If user’s oscilloscope doesn’t have such function, user have to manually set the corresponding attenuation ratio, for instance, if the probe is H level (0.01V/A), the oscilloscope should be 100X; if the probe is L level (0.1V/A), oscilloscope is 10X. User can connect the BNC output port with the input port of the oscilloscope with standard double terminal BNC cable.
Turn the switch to ON, and the power indicator will light up green.
9

According to the value of the current under test, choose the correct range by pressing button. Attention: Different ranges correspond to different attenuation ratio of the oscilloscope. Press the Auto Zero button. The buzzer will beep for twice, or it will have a long and continuous beep
meaning the failure of Auto Zero .The external magnetic field can have a little influence to the DC zero, so do not move the device after Auto Zero. Open the clamp of the probe and clamp the conductor under test. Attention: There’s direction tip on the current probe clamp. If the direction of the current fits the tip, output will be positive; On the contrary, the result is negative. Adjust the vertical sensitivity of the oscilloscope to get a stable waveform.

5.Mechanic Characteristics

Size of the front current clamp
Size of the back output box
Operation altitude Maximum diameter of the conductor under test Length of the cable connecting current clamp and output box Length of double terminal BNC cable
Weight

About 1002060mm About 1373335mm 0~2000 meter 12mm ø 1 meter 1 meter About 223g(without battery)

6.Environment characteristics

Operating temperature Storing temperature Operating relative humidity
Pollution Degree

0+50 -20+80 0 to +40, 95%RH +40~+50, 45%RH
Level 2

10

7. Maintenance
If the product is in the warranty period and used correctly, and at the same time the malfunction is caused by the flaws of product itself and have not been disassemble, the company will give free repair to the product. Clamp: Please keep the clamp clean. After long time use, please use soft cloth together with alcohol
to erase the dirt. Please keep the clamp away from damp environment, not to mention direction contact with water. Handle: Please use clean cloth or sponge to clean the handle. Please use little alcohol instead of water to erase the dirt and parch it. To maintain the performance of the product, there can be one check or calibration every year.

8. Troubleshoot

Problem
No output signal or amplitude is low
Power indicator is off when the probe is on.

Reason Power is off Oscilloscope is AC mode
Clamp isn’t closed Battery voltage is lower than 6.5V

Treatment
Turn on the power. Please set it to DC mode Check the clamp, close it completely.
Change the battery

Amplitude is half

The input impedance is 50 Set it to 1M

11

9.Packing List
Packaging Name Current probe 9V battery DC12V/1.2A adaptor BNC output cable Tool box Instruction book Warranty card

Quantity 1 1 1 1 1 1 1

12

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals