BRISTAN D1 Showers Wall Mount Fixing Kit Instruction Manual
- June 16, 2024
- BRISTAN
Table of Contents
BRISTAN D1 Showers Wall Mount Fixing Kit Instruction Manual
Installation Instructions & User Guide
Please leave these instructions with the end user
Specifications
Dynamic Water Pressure
Min: 1.0 bar
Max: 5.0 bar
Maximum Static Pressure : 10.0 bar
Inlet Water Temperature
Min 5°C; Max 25°C
Recommended 60°C; Max 65°C
IMPORTANT
The inlet hot water must be at least 10°C above the required blend
temperature.
**Factory pre-set 38°C
**
Inlet Connections
1/2” Compression
Inlet Dimensions
Tools Required
Pencil| Flat head Screwdriver| Drill
---|---|---
Cross head Screwdrive| Spanner| Pipe Cutter
Hexagonal Keys| Socket
Spanner|
Pack Contents
Operation
Prior to Installation
All products manufactured and supplied by Bristan are safe to use provided
that they are installed, operated and receive regular maintenance in
accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of The
Water Supply (Water Fittings) Regulations (Northern Ireland) 2009 and The
Water Supply (Water Fittings) (Scotland) Byelaws 2014. For full Installation
Requirements & Notes (IRN) please visit www.wrasapprovals.co.uk/approvals-
directory
Before installing this product the water supply must be thoroughly flushed in
order to remove any swarf, solder etc. Full access must bemade available for
future maintenance/servicing purposes. Isolation valves must be fitted to the
inlet water supplies to ensure ease of future maintenance.
Before drilling into walls, check that there are no hidden electrical wires,
cables or water supply pipes. This can be checked with the aid of an
electronic detector. If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
Spares
To replace any spare parts for your product, please contact our Customer Services Department on 0330 026 6273, where our team of expert advisors will be happy to help.
Thank you for choosing Bristan, the UK’s leading taps and showers expert. We have designed this product with your enjoyment in mind. To ensure that it works to its full potential, it needs to be fitted correctly. These fitting instructions have been created to give you all of the information you need and, if you need any further help, please do not hesitate to give us a call on 0330 026 6273
Important Safety Information
Please make sure you read these instructions and retain for future use.
All products manufactured by Bristan are safe, providing they are installed
and used
correctly and also receive maintenance when needed.
These fittings, including the connecting water and waste system need to be
installed
in accordance with and meet the requirements of the Water Supply Regulations
1999
(Water Fittings) and current by-laws. If you are in doubt about your ability
to install
this product correctly or safely, you should employ the services of an
experienced
qualified plumber.
This product must not be modified in any way otherwise this will invalidate
the
guarantee. Remove all packaging and check the contents for damage before
starting installation.
Warning:
Before installing the new mixer valve it is essential that you thoroughly
flush through the pipework in order to remove any remaining swarf, solder,
etc. Failure to carry out this procedure could cause problems or damage to the
workings of the mixer tap. Fitting isolating valves to the inlet feeds is
required for ease of maintenance.
Warning : Do not operate the mixer if you suspect it is frozen. Do not site the mixer valve where it might be subjected to freezing conditions. Consider the following whilst using power tools:
- Prior to drilling into walls, check there are no hidden electrical cables or wires and there are also no water pipes. These can potentially be found using an electrical or metal detector. You may also need to know some of the schematics of previous installations to determine the suitability and accommodation of the installation.
- Wear the correct PPE, especially ear, eye and hand protection when using power tools. Unplug any mains equipment after use.
- Keep electrical equipment away from sources of water.
- If a blow-lamp is used when plumbing, the flame must be kept well away from the product otherwise damage may occur.
If in doubt, contact a registered plumber, your Local Water Authority or the Secretary of The Institute of Plumbing, address as follows;-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex, RM12 6NB
Tel :01708 47279
Installation Requirements
Please refer to your specific shower contents page for specification information.
These showers are designed to be used in conjunction with the kit supplied, or Bristan shower kits where not supplied. We cannot guarantee compatibility or adequate performance when used with other kits. This would also invalidate your guarantee. Please refer to the installation manual supplied with your Bristan shower kits for their specification information.
This shower valve must be installed in compliance with current water regulations. If you have any doubts about the water regulation requirements contact your local water services provider or use the services of a professional plumber.
This shower valve is suitable for use with the following water supply systems:
-
Gravity Fed Hot and Cold
(pressure imbalance should not exceed
a ratio of 5:1 – see Specification section) -
Gravity Fed Hot and Mains Cold
(pressure imbalance should not exceed
a ratio of 5:1 – see Specification section) -
Instantaneous water heater (combination boiler)
-
Unvented System
-
Pumped System
IMPORTANT: If you install this shower valve with a gravity fed system, there must be a minimum head (vertical distance) from the underside of the cold water storage tank to the outlet of at least 1 metre for every 0.1 bar of minimum pressure required.
Note: Pumped system (with Essex flange) If you install this shower valve to a pumped gravity fed system where the minimum head (vertical distance) from the underside of the cold water storage tank to the top of the hot water cylinder is less than 1 metre we recommend an Essex flange is used as shown.
Flushing Pipe-work
IMPORTANT: Before connecting the shower valve (see ‘Installation’ on
page 7), the supply pipe-work must be flushed to clear debris before
connecting the shower. Debris will reduce the performance and life of the bar
shower and Wall Mount.
Gravity Fed Hot and Cold
Gravity Fed Hot and Mains Cold
Key:
Isolating Valve
Reducing Valve
Shower Valve
Pump
Essex Flange
Instantaneous Water Heater
Unvented System
**Pumped System
Pumped System** (with Essex flange)
Installation
PLEASE NOTE – Wall Mounts shown in these instructions are for illustration purposes only. WMNT12 and WMNT12 SQ can be fitted using these instructions.
- Identify the required position of the valve and prepare the water supply pipes. Supply
pipes should be 150mm apart Using the rubber fixing plate supplied with the wall mount, mark and drill holes.
-
Secure the rubber backplate and backplate into place.
-
Secure the isolator onto the backplate ensuring the olive is positioned over the pipework correctly
-
Push shrouds to the back of the wall outlet, securing them against the rubber fixing plate.
-
Secure the shower to the wall mount.
Now refer to your kit instructions to install your shower kit if supplied.
If
your shower is TMV approved, please refer to the TMV manual supplied to
commission your shower.
Isolation
-
Remove the concealing cap from the shroud.
-
Rotate the shroud until the opening aligns with the isolation screw. Turn the screw to isolate the water. Reverse the process when turning the water back on.
PLEASE NOTE – Wall Mounts shown in these instructions are for illustration purposes only. WMNT12 and WMNT12 SQ can be fitted following these instructions. Check your contents page for more details specific to your shower.
Temperature Setting
-
Turn the temperature handle to the max. setting and remove the temperature handle.
-
Turn flow handle to ‘on’ position, letting the temperature stabilize.
-
Turn cartridge spindle clockwise to decrease the temperature. Turn cartridge spindle anti-clockwise to increase the temperature.
-
Reverse steps 1-2 to reinstall the cartridge and handle.
IMPORTANT
TMV showers are pre-set to 41˚C as per TMV standards. If the maximum
temperature is increased the shower will no longer comply with the TMV scheme.
PLEASE NOTE – Bar showers shown in these instructions are for illustration purposes only. All bar showers can be fitted/maintained following these instructions. Check your contents page for more details specific to your shower.
General Cleaning
Brittan products are made from premium materials, with hand polished, PVD, EPD or electroplated finishes.
Your bar shower should be regularly cleaned with warm water, a mild pH-neutral liquid soap, and polished with a soft cloth. Any residues from soap, toothpaste, shampoos and shower gels can cause blemishes if not rinsed off straight after use.
Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool or anything similar. Some surfaces such as nickel and pewter may be affected by the dye found in some cloths, so it is also important to avoid hanging cloths on fittings/barshowers etc.
Maintenance – Cartridge/Valve Cleaning
PLEASE NOTE – Bar showers shown in these instructions are for illustration purposes only. All bar showers can be fitted/maintained following these instructions.
-
Remove temperature and flow handle.
-
DEPENDING ON YOUR SHOWER TYPE:
Remove the cartridge retaining nut and diverter cartridge
Unscrew the flow valve. -
Remove adaptor, nut and cartridge. Depending on your shower you may need a specific cartridge tool (not supplied), or check for the grub screw underneath the bar valve to remove.
-
Remove O-rings and soak all components in de-scaler and wash off in clean water.
Examine all seals and replace if needed. Use WRAS approved silicon based grease on all seals. -
Replace nut and temperature stop. Ensure the raised side is facing towards the back of the valve.
-
Turn cartridge spindle clockwise to decrease the temperature. Turn cartridge spindle anti-clockwise to increase the temperature.
-
Slide handle onto adaptor and turn clockwise until you meet resistance.
-
Reverse steps 1-2 to reinstall the valve/ cartridge and secure handles. Refer to the ‘Temperature Setting’ maintenance steps to re-calibrate the max. temperature.
Servicing Intervals | Spare Parts |
---|
To reduce the build up of limescale and to ensure this shower works to its maximum performance we recommend this shower is serviced every 6-12 months depending on the hardness of your water| To replace any spare parts for your shower why not scan the below QR Code and search for your product.
Troubleshooting
Symptom| Cause| Remedy
No flow or low flow rate
| Partially closed isolation valve.| Open isolation valve.
Instantaneous water heater cycles on and off as flow rate or pressure is too
low.| Increase water flow rate or pressure through system.
Head of water is below the minimum distance required.| Refer to the
specification for the minimum distance required.
Are the water supply pressures balanced?| If pressures are unbalanced, a
pressure reducing valve should be used for optimum performance.
Hot or cold water being drawn off else- where causing pressure changes or
instan- taneous boiler temperature changes.| Do not use other water outlets
when using the shower.
Airlock or partial blockage in the supply pipework.| Flush through pipework
and filters to ensure removal of debris and any airlocks.
Hot/Cold water supply has failed| Check the hot and cold feeds. The shower
will not work if either fails.
Outlet Water Tempera- ture too Hot/Cold
| Maximum Water Temperature needs adjusting.| Refer to the Temperature Setting
section to set your desired maximum temperature.
Filter/pipe blockage| Flush through pipework and filters to ensure removal of
debris and any airlocks.
Installation conditions outside operating parameters.| Refer to the
specification for the minimum distance required.
Hot water temperature is less than 10°C above the required blend temperature|
Adjust hot water temperature or wait for water to reheat if a stored water
system is used.
Instantaneous water not igniting because the water flow rate is too low.|
Increase water flow rate through the system. Refer to the Maintenance section
to clean/ check the cartridge and filters for any damage. Contact your boiler
manufacturer.
Instantaneous water not igniting because the water pressure is too low.| Refer
to the specification for system requirements. Increase water pressure through
the system.Contact your boiler manufacturer.
Only hot/cold water from Shower Valve| Inlet water supplies are reversed.|
Check the water inlet connections are the correct way around: Hot on the left,
Cold on the right when viewed from the front.Rework pipework as necessary.
Filter/pipe blockage| Flush through pipework and filters to ensure removal of
debris and any airlocks.
Water dripping from shower| This is normal for a short time after using the
shower.| This is caused by residual water tension, the build up of water in
the shower.
If water continues to drip, possibly due to the cartridge| Remove cartridge
and clean, refer to ‘Maintenance’ section before starting any maintenance.
Shower does not turn on| Closed isolation valve.| Open isolation valve.
Mains water supply turned off.| Turn on mains water supply.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained
advisors.
11
Issue : D1
Part Number : Bar SHWR WMNT
Bristan Group Ltd.
UK : Bristan Group, B78 1SG.
EU : Masco Europe S.à.r.l. 14 Rue Strachen
6933 Mensdorf
Luxembourg
Customer Service: +44330 026 6273
Web: www.bristan.com
Email: enquire@bristan.com
A Masco Company
At Bristan, we want to make things as easy as possible for our customers.
That’s why we offer solid guarantees on all our products, effective from the
date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your
product.
Alternatively visit
www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/service-
centre/guarantees