DynaLabs DYN-C-1000-LN Uniaxial Capacitive Accelerometers User Manual
- June 3, 2024
- Dynalabs
Table of Contents
DynaLabs DYN-C-1000-LN Uniaxial Capacitive Accelerometers
Product Support
If at any time you have questions or problems with the DYN-C-1000-LN sensors, please contact a Dynalabs engineer at
- Phone: +90 312 266 33 34 (9 a.m. to 5 p.m., UTC +3)
- E-mail: info@dynalabs.com.tr
Warranty
Our products are warranted against defective materials and workmanship for one year. Defects arising from user errors are not covered by the warranty.
Copyright
All copyrights of this manual belonging to Dynalabs products are reserved. It
cannot be reproduced without written consent.
Disclaimer
Dynalabs Ltd. provides this publication “as is” without warranty of any kind,
express or implied, including but not limited to, the implied warranties of
merchantability or fitness for a particular purpose. This document is subject
to change without notice, and should not be construed as a commitment or
representation by Dynalabs Ltd. This publication may contain inaccuracies or
typographical errors. Dynalabs Ltd. will periodically update the material for
inclusion in new editions. Changes and improvements to the product described
in this manual may be made at any time.
Introduction
Capacitive accelerometers are based on proven micro-electro-mechanical systems
(MEMS) technology. These capacitive accelerometers are reliable and long-term
stable. These sensors are Differential Ended type DC response sensors. The
advantages of these sensors are their outstanding temperature stability,
external noise immunity and their lightweight. These sensors feature standard
reliable aluminum housing with protection class IP68. Steel housing is also
possible.
Dynalabs LN accelerometers provide Low noise – high resolution with an
outstanding noise performance from 9 to 680 μg/√Hz. These accelerometers
provide a wide frequency range (±5%) from 250 Hz to 1,500 Hz.
DYN-C-1000-LN sensors offer the following options;
- Custom Cable Length
- Custom Housing Material
- Custom Connector
- Base plate
General Information
Unpacking and Inspection
Dynalabs products provide adequate protection for undamaged products to be
transported. Document the damages that occur indirectly during the transport
and contact the customer representative.
System Components
The DYN-C-1000-LN has the following components:
- MEMS Sensor
- Calibration Certificate
- Product Manual
Specifications
Table 1: Specifications datasheet
| | 1002LN| 1005LN| 1010LN| 1030LN| 1050LN|
1100LN| 1200LN
---|---|---|---|---|---|---|---|---
Full scale acceceleration| (g)| ±2| ±5| ±10| ±30| ±50| ±100| ±200
Sensitivity| (mV/ g)| 1,350| 540| 270| 90| 54| 27| 13.5
Frequency
range (±5%)
| (Hz)| 700| 1,150| 2,000| 2,300| 2,700| 2,900| 2,500
Non-linearity (full scale)| (%)| 0.15| 0.15| 0.15| 0.15| 0.15| 0.15| 0.15
Noise (in band)| (μg/
√Hz)
| 9| 21| 40| 100| 180| 340| 680
Bias temperature| (mg/
°C)
| ±0.2| ± 0.5| ± 1| ± 3| ± 5| ± 10| ± 20
Shock survivability| (g)| 2,500| 2,500| 2,500| 3,000| 3,000| 3,000| 3,000
Environmental
Table 2: Environmental Specifications datasheet
Protection Level | IP 68 |
---|---|
Operating Voltage | 5 V – 20 V |
Operating Temperature | -40 °C to +100 °C |
Operating Current Consumption mA | 7 mA |
Isolation | Case isolated |
Physical
Table 3: Physical Specifications datasheet
Sensing Element | MEMS Capacitive |
---|---|
Housing Material | Aluminum or Steel |
Connector (Optional) | D-Sub 9 or 15 pin, Lemo, Binder |
Mounting | Adhesive or screw mount |
Base plate (Optional) | Aluminum or Steel |
__
Weight (without cable)
| 10 g (aluminum)
20 g (steel)
Outline Drawing
The dimensional properties of DYN-C-1000-LN sensors are given below
;
Operation and Installation
General
The general sensor connector configuration is given below; Cable Code/Pin
Configuration:
- Red : V + Power supply voltage +5 to +20 VDC
- Black : Ground Power GND
- X : Yellow : Signal(+) Positive, analog output voltage signal for differential mode.
Blue : Signal(-) Negative, analog output voltage signal for differential mode.
WARNING
Never connect the power supply and/or the power ground to yellow and/or blue
cables.
Never connect the power supply to the power ground. Always use a clean power
source and check the voltage range.
Sensor Static Calibration Verification
Using gravity, voltage values are measured in the + and – gravity directions, providing a value of ±1 g. The measurement should be made as follows;
- When the sensitivity value of 1000LN series sensors is used with the data acquisition system, the sensor shows +1 g with the effect of gravity in the direction of the arrow sign.
- When the sensor is in the opposite direction of the arrow, it shows -1 g with the effect of gravity.
Using gravity, the voltage values that provide 1 g in the + and – directions are measured and compared with the catalog value. The calibration value should be close to the catalog value with 10% tolerance. Sensor catalog sensitivity values are given in Table 1.
Declaration of Conformity
This declaration of conformity is issued under the sole responsibility of the manufacturer. The product(s) are developed, produced and tested according to following EC- directives:
- 2014/35/EU – Low Voltage Directive (LVD)
- 2006/42/EU – Machinery Safety Directive
- 2015/863/EU – RoHS Directive
Applied standards:
- EN 61010-1:2010
- EN ISO 12100:2010
- MIL-STD-810-H-2019 (Test Methods: 501.7 – High Temperature, 502.7 – Low Temperature, 514.8 – Vibration, 516.8 – Shock)
DYNALABS MÜHENDİSLİK SANAYİ TİCARET LİMİTED ŞİRKETİ declares
that above mentioned products meet all the requirements of the above mentioned
standards and regulations. Murat Aykan, Technical Manager Ankara, 15.07.2021