DYN-G-6000 MEMS Gyroscopes Dynalabs Instruction Manual

June 3, 2024
Dynalabs

DYN-G-6000 MEMS Gyroscopes Dynalabs Instruction Manual

Model: DYN-G-6000
75°/s / 150°/s / 300°/s / 900°/s
Product Manual

Product Support

If at any time you have questions or problems with the DYN-G-6000 sensors, please contact a Dynalabs engineer at:

Phone: +90 312 266 33 34 (9 a.m. to 5 p.m., UTC +3)
E-mail: info@dynalabs.com.tr

Warranty
Our products are warranted against defective materials and workmanship for one year. Defects arising from user errors are not covered by the warranty.

Copyright
All copyrights of this manual belonging to Dynalabs products are reserved. It cannot be reproduced without written consent.

Disclaimer
Dynalabs Ltd. provides this publication “as is” without warranty of any kind, express or implied, including but not limited to, the implied warranties of merchantability or fitness for a particular purpose. This document is subject to change without notice, and should not be construed as a commitment or representation by Dynalabs Ltd.

This publication may contain inaccuracies or typographical errors. Dynalabs Ltd. will periodically update the material for inclusion in new editions. Changes and improvements to the product described in this manual may be made at any time.

1) Introduction

Dynalabs MEMS based gyroscopes are designed by micro-mechanical silicon structures. Thus, gyroscopes are insensitive to external impacts and vibrations. For harsh environmental conditions Dynalabs gyroscopes are preferred. 6000 Series Uniaxial Gyroscopes feature a lightweight, reliable aluminum housing and they have an integrated cable with configurable length and connectors.

DYN-G-6000 sensors offer the following options;

  • Custom Cable Length (5m standard cable)
  • Custom Housing Material
  • Custom Connector
  • Base plate

2) General Information

2.1) Unpacking and Inspection
Dynalabs products provide adequate protection for undamaged products to be transported. Document the damages that occur indirectly during the transport and contact the customer representative.

2.2) System Components
The DYN-G-6000 has the following components:

  • MEMS Sensor
  • Calibration Certificate
  • Product Manual

2.3) Specifications
Table 1: Specifications datasheet

FIG 2 Specifications

Environmental
Table 2 Environmental specifications datasheet

FIG 3 Environmental specifications datasheet

Physical
Table 3 Physical specifications datasheet

FIG 4 Physical specifications datasheet

2.4) Outline Drawing
The dimensional properties of DYN-G-6000 sensors are given below.

FIG 5 Outline Drawing

3) Operation and Installation

3.1) General
The general sensor connector configuration is given below;
Cable Code/Pin Configuration:

FIG 6 Operation and Installation

WARNING
Never connect the power supply and/or the power ground to yellow cables.

Never connect the power supply to the power ground. Always use a clean power source and check the voltage range.

5) Declaration of Conformity

This declaration of conformity is issued under the sole responsibility of the manufacturer. The product(s) are developed, produced and tested according to following EC- directives:

  • 2014/35/EU – Low Voltage Directive (LVD)
  • 2006/42/EU – Machinery Safety Directive
  • 2015/863/EU – RoHS Directive

Applied standards:

  • EN 61010-1:2010
  • EN ISO 12100:2010
  • MIL-STD-810-H-2019 (Test Methods: 501.7 – High Temperature, 502.7 – Low Temperature, 514.8 – Vibration, 516.8 – Shock)

DYNALABS MÜHENDİSLİK SANAYİ TİCARET LİMİTED ŞİRKETİ declares that above mentioned products meet all the requirements of the above mentioned standards and regulations.

Murat Aykan, Technical Manager
Ankara, 15.07.2021

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>