  • Product Name: Viper Vehicle Telematics
  • Compatibility: Works with machines equipped with CAN bus
  • Subscription Requirement: Gold subscription on Slingshot account

Product Usage Instructions

  1. Locate the vehicle CAN tee cable (P/N 115-0172-602) and connect it to the diagnostic port on the machine.
  2. Connect the opposite end of the vehicle CAN tee cable to Port 5 at the back side of the Viper 4/4+.

AGCO ROGATOR C Installation

  1. Disconnect the X-63 connector plugged into the front bulkhead connector at the electrical panel on the right side of the cab.
  2. Remove the retaining nut from the bulkhead connector and pull the connector out of the electrical panel.
  3. Remove the dust plug from cavity #19 and #20 of the connector.
  4. Insert the yellow wire into cavity #19 and the green wire into cavity #20 of the Raven vehicle CAN cable (P/N 115-2001-074).
  5. Connect the X-59 connector to the Raven vehicle CAN cable.
  6. Reinstall the bulkhead connector and reconnect the X-63 connector.

Fendt Rogator 900 Series Installation

  1. Remove the Access Cover and Bulkhead Plate.
  2. Disconnect the 12 12-pin connector from the ECU and pull it out through the bulkhead plate opening.
  3. Connect cable (P/N 115-2001-078) to the 12 12-pin connector and insert the remaining connector into the ECU.
  4. Insert pins from the ECU Cable into pin locations 22 and 23 in the bulkhead plate connector.
  5. Disconnect the corresponding connector from the bulkhead plate and insert pins from Tee Adapter Viper 4+ Cable (P/N 115-2001-077) into pin locations 22 and 23 in the bulkhead plate connector.

FAQ

  • Q: What subscription level is required to access machine performance information?
  • A: A Gold subscription on a Slingshot account is required to access machine performance information.

VIPER VEHICLE TELEMATICS INSTALLATION GUIDE

SLINGSHOT MACHINE VIEW AND FLEET ANALYTICS

  • Slingshot Machine View and Fleet Analytics provide real-time machine and fleet information so users may make informed operational decisions.
  • Machine View monitors the machine position and provides a quick summary of the machine activity status, product level, and fuel/DEF levels.

VIPER-900-Series-Slingshot-Machine-FIG-1

  • Fleet Analytics offers statistics on productivity and efficiency – acres per day, fuel consumption, transit/working/idle time breakdown, and more.

VIPER-900-Series-Slingshot-Machine-FIG-2

NOTE: A Slingshot account with at least a Gold subscription is required to take advantage of these features. Contact a Slingshot dealer to complete the system configuration.

VIPER VEHICLE TELEMATICS INSTALLATION

  • To access machine performance information, the Viper 4+ must be connected to the vehicle CAN bus of the machine.

UNIVERSAL INSTALLATION

  1. Locate the vehicle CAN tee cable (P/N 115-0172-602) and connect it to the diagnostic port located on the machine.
    NOTE: If another device is already installed in the diagnostic port, relocate the previously installed device to the spare diagnostic port on the vehicle CAN tee cable.VIPER-900-Series-Slingshot-Machine-
FIG-3

  2. Connect the opposite end of the vehicle CAN tee cable to Port 5 at the back side of the Viper 4/4+.
    NOTE: If another cable is already connected to Port 5, relocate the previously installed cable to the mating connector on the vehicle CAN tee cable.VIPER-900-Series-Slingshot-Machine-FIG-4

AGCO ROGATOR C INSTALLATION

  1. Disconnect the X-63 connector plugged into the front bulkhead connector at the electrical panel at the right side of the cab.VIPER-900-Series-Slingshot-Machine-FIG-5
  2. Remove the retaining nut from the bulkhead connector and pull the connector out of the electrical panel.
  3. Remove the dust plug from cavity #19 and from cavity #20 of the connector.
  4. Locate the Raven vehicle CAN cable (P/N 115-2001-074). Insert the yellow wire into cavity #19, and insert the green wire into cavity #20.VIPER-900-Series-Slingshot-Machine-FIG-6
  5. Identify the X-59 J1939 connector inside the electrical panel and remove the dust plug.VIPER-900-Series-Slingshot-Machine-FIG-7
  6. Connect the X-59 connector to the Raven vehicle CAN cable.VIPER-900-Series-Slingshot-Machine-FIG-8
  7. Reinstall the bulkhead connector and reconnect the X-63 connector.

FENDT ROGATOR 900 SERIES INSTALLATION

Kit Part Number 117-0171-907

  1. Remove the Access Cover.VIPER-900-Series-Slingshot-Machine-FIG-9
  2. Remove the Bulkhead Plate.VIPER-900-Series-Slingshot-Machine-FIG-10
  3. Disconnect the 12-pin connector from the ECU.VIPER-900-Series-Slingshot-Machine-FIG-11
  4. Pull out the 12 12-pin connector through the bulkhead plate opening.
  5. Connect the cable (P/N 115-2001-078) to the 12 12-pin connector that was previously removed from the ECU.
  6. Connect the remaining connector to the ECU.
  7. Insert the pins from the ECU Cable into pin locations 22 and 23 as shown in the bulkhead plate connector.VIPER-900-Series-Slingshot-Machine-FIG-14
  8. Disconnect the corresponding connector from the bulkhead plate.VIPER-900-Series-Slingshot-Machine-FIG-15
  9. Inset the Pins from the Tee Adapter Viper 4+ Cable (P/N 115-2001-077) into pin locations 22 and 23 in the bulkhead plate connector.VIPER-900-Series-Slingshot-Machine-FIG-16
  10. Route the Tee Adapter Viper 4+ Cable along existing harnesses.VIPER-900-Series-Slingshot-Machine-FIG-17
  11. Disconnect the CAN cable from the rear of the Viper 4.VIPER-900-Series-Slingshot-Machine-FIG-18
  12. Connect the Tee Adapter Viper 4+ Cable (P/N 115-2001-077) to the CAN Cable that was removed from the Viper 4.
  13. Connect the remaining connector to the rear of the Viper 4.
  14. Install the Access Panel and Bulkhead Plate.
  15. Install the Bulkhead Plate Connector.
  16. Secure the Viper Tee Adapter Cable with tie straps.