Coway APMS-1020A Air Purifier Instruction Manual
- June 11, 2024
- Coway
Table of Contents
- FEATURES
- SAFETY INFORMATION
- PARTS NAME
- AIR PURIFICATION PROCESS
- BEFORE USE
- INDICATORS AND BUTTONS
- ADJUST PARTICLE SENSOR
- HOW TO ADD WATER
- HOW TO CLEAN
- FILTER REPLACEMENT
- TROUBLESHOOTING
- PRODUCT SPECIFICATIONS
- WARRANTY CARD OR WARRANTY LETTER
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Coway Air Purifier
APMS-1020A
This product is for domestic market only. Product voltage does not work
overseas.
For your safety and proper use of the product, please read this user manual
before use.
Warranty card is included in this user manual.
This paper can be recycled.
FEATURES
Excellent air purification
A powerful Green Max2 filter eliminates airborne fine dust indoors, and the
filter system is optimized to quickly remove contaminants.
Combined air purification/natural humidification
This is a combined product with a natural humidification system due to its
humidifying filter and an air purification system to remove fine dust and
harmful gases.
Comfortable natural humidification due to the humidification filter
A humidification filter and humidity sensor adjust the amount of
humidification according to indoor temperature and humidity.
Excellent purification and humidification
The vaporizing humidification system has a capacity of over 600 mL per hour.
3-step automatic operation via the particle sensor
The purifier always operates efficiently by detecting the indoor contamination
status instantly through the particle sensor and automatically controlling the
air volume based on that status when auto mode is selected.
Humidification filter drying
Humidification filter drying mode operates to clean the water tray and
humidifying filter even when the power is off.
DEAR CUSTOMERS
Thank you for using the Coway air purifier.
Please read this user manual carefully for correct use and maintenance of the
product.
You can refer to the user manual to troubleshoot for product issues while
using it.
Please keep this user manual in a safe place as it includes the product
warranty.
SAFETY INFORMATION
Please follow the instructions as they are for your safety.
Please read this information to ensure your safety and prevent property
damage.
Please read the cautions carefully and use the product correctly.
DANGER : FAILING TO FOLLOW THE PRECAUTIONS BELOW MAY RESULT IN SERIOUS INJURY OR EVEN DEATH.
Do not use damaged power plugs or loose sockets.
The power plug must be plugged into only 220 V – 240 V~ 50 Hz, 60 Hz sockets.
Do not pull on the power cord to move the device.
Do not touch the power plug with wet hands.
To avoid damaging or warping the power cord, do not use excessive force to
bend the power cord or put heavy objects on top of it.
Do not repeatedly connect and disconnect the power plug.
If water enters the power supply, unplug the power and completely dry before
using again.
Be sure to unplug the power during product repair, maintenance, or part
replacement.
If the power plug pins or contact area are covered in dust or water, the power
will be blocked. Wipe them clean and then dry before use.
Do not plug several electric appliances into one socket, and use only a
dedicated socket.
Unplug the power when not used for a long time.
Do not carelessly connect or tamper with the power cord.
If the power cord is damaged, do not replace it yourself. Contact a service
center to have it replaced.
Do not install near electric heaters.
Do not put on top of electric products like heaters or televisions.
Do not install in places with a lot of humidity or dust or places where water
(rainwater) splashes.
Do not use or store combustible gases or flammable materials near this
product.
Do not insert sharp objects such as picks into the particle sensor.
If there is a strange sound, burning smell, or smoke from the device,
immediately unplug the power plug and contact a service center.
Never immerse the product in water.
Do not spray flammable materials such as insecticides or air fresheners on the
air intake.
Do not open, repair, or modify the device yourself.
Do not put bowls of water, chemicals, food, small metal objects, or flammable
materials on top of this product.
Unplug the power before cleaning.
Do not spray water directly on the device or use benzene, thinners, etc. to
wipe it during cleaning.
Do not use excessive force on the outside of the water tank.
Fully empty the water tray and water tank before moving the purifier.
Do not use bactericide (adjuvants) for humidifiers.
Do not put fingers or foreign matter into the intake or outlet.
WARNING : FAILING TO FOLLOW THE PRECAUTIONS BELOW MAY RESULT IN
CONSIDERABLE PHYSICAL INJURY OR PROPERTY DAMAGE.
Do not unplug by pulling on the power cord.
Do not let children hang from or climb on the device.
CAUTION : FAILING TO FOLLOW THE PRECAUTIONS BELOW MAY RESULT IN SLIGHT
PHYSICAL INJURY OR PROPERTY DAMAGE.
Do not install on a slope.
Do not excessively impact or use excessive force on this product.
Use at least 20cm away from walls or other objects on each side.
Install the purifier in a place where it is not blocked on any side so air can
circulate well.
Install at least 2m away from TVs and other electronic items.
Do not use in BBQ or other restaurants where there may be heavy odor, smoke,
or oil.
Do not use in direct sunlight.
Replace the filter with a new one when the time comes.
Periodically wash the pre-filter and dry it well in a shady place with good
ventilation before use.
Do not push or lean on the purifier. Otherwise, the device may fall over.
Use with the rear cover, water tank, and water tray correctly installed.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Cleaning and user maintenance shall not be made by children without
supervision.
Children shall not play with the appliance.
Be aware that high humidity levels may encourage the growth of biological
organisms in the environment.
Do not permit the area around the humidifier to become damp or wet. If
dampness occurs, turn the output of the humidifier down. If the humidifier
output volume cannot be turned down, use the humidifier intermittently. Do not
allow absorbent materials, such as carpeting, curtains, drapes, or
tablecloths, to become damp.
Unplug the appliance during filling and cleaning.
Never leave water in the reservoir when the appliance is not in use.
Empty and clean the humidifier before storage. Clean the humidifier before
next use.
PARTS NAME
Front / Back
Top
Accessories
AIR PURIFICATION PROCESS
Pre-filter
Removes large dust and mold, hair, pet fur, etc.
Fine dust filter(Optional)
This filter is placed in front of the Green Max2 filter to catch fine dust,
fur, etc. and protects the Green Max2 filter.
Green Max2 filter (Activated Carbon + GreenHEPA™)
Captures and reduces more than 99 % of VOCs and odors such as NH3, CH3CHO. It
also captures and reduces up to 99.97 % of airborne particles, allergens, and
contaminants down to 0.3 microns in size.
- Coway GreenHEPA™ filter are treated with preservatives(Silver sodium hydrogen zirconium phosphate and thiabendazole) to protect the filter from the growth of mold and bacteria and prolong filter life.
Water tank
Stores 2.5 L of water and supplies water to the water tray.
Water tray
Keeps the water level and volume supplied to the humidifying filter at a set
level.
Humidifying filter
This component has a large surface area to transmit moisture through the
passages through which dry, purified, filtered air passes and can rapidly
absorb water to humidify naturally.
- Coway Humidifying Filter is treated with preservatives (Zinc pyrithione) to protect the filter from the growth of mold and bacteria and prolong filter life.
BEFORE USE
Be sure to read before use!
This product is exclusively 220 V – 240 V~
50 Hz, 60 Hz.
Only plug the power plug into sockets of 220 V – 240 V~ 50 Hz, 60 Hz.
Tips
– Be sure to remove the plastic packaging before installing filters.
– This product is for household use. Only use it indoors.
– When not in use, remove the power plug from the socket.
– When assembling filters, check the front of the filters.
Filter order : Pre-filter Fine dust filter(Optional) Green Max2 filter
Air purification filter
-
Open the front cover.
Pull the upper part of the front cover to open. -
Take out the filter and remove the plastic packaging.
Remove the plastic packaging from filters, excluding the pre-filter, and assemble them in the purifier in order.
- Filter assembly order : Green Max2 filter Fine dust filter(Optional) Pre-filter
3. Reattach the front cover.
Put the 2 tabs on the bottom part of the front cover into their slots and push to install. - If the front cover is not properly attached, the product will not operate.
Humidifying filter
- Lift the water tank cover, then grasp the water tank handle and remove the water tank.
- Detach the front cover.
- Pull the water tray forward as in the picture to remove it.
- Remove the plastic packaging from the humidifying filter and then install it.
- Combine the water tray and water tank in order.
- Close the front cover.
Tips
– If there is scaling on the humidifying filter, the humidification volume may
decrease. Clean at least once per week. (See p. 20)
– If the water tank and water tray are not installed correctly, the purifier
may not work.
INDICATORS AND BUTTONS
Indicators
1| | Mode indicator
Each time the mode button is pressed, the purifier cycles through AUTO CALM
MAX, and the indicator for the final selected mode is illuminated.
---|---|---
2| | Air volume indicator
This indicator is illuminated when level 1/2/3 air volume is on.
3| | Multi-purification indicator
This indicator is illuminated when multipurification is on.
4| | Purification/humidification indicator
This indicator is illuminated when purification/humidification is on.
5| | Illumination sensor
This sensor detects ambient light at night to convert to calm mode.
- This feature is possible in auto mode, but in manual mode, it does not convert.
6| | Current humidity/status indicator
When the current humidity button is pressed, the purifier displays the ambient humidity where the purifier is installed. The current humidity level is displayed in numbers on the front for 3 seconds, and then the fine dust level is displayed. The humidity level is displayed in increments of 5%.
The fine dust level is displayed even if the current humidity button is pressed again.
– Filter drying : The indicator is on while the humidifying filter drying feature is operating.
– Adding/draining water: The indicator is on when water should be added or drained.
– While the buttons are locked, -L- is displayed.
– While the buttons are unlocked, UL is displayed.
Buttons
1| | Power button
Use when turning the purifier on and off.
- The purifier begins operating in auto mode the first time, and if it is turned off and on again while in operation, runs in the mode it was in before it stopped.
---|---|---
2| | Mode button
Press the mode button to select an operating mode, cycling between “AUTO CALM MAX”.
3| | Air volume button
Press the air volume button to cycle through level 1 level 2 level 3.
(If you press the air volume button while in AUTO/CALM/MAX mode, the purifier immediately switches to manual mode.)
4| | Multi-purification button
Press the multi-purification button to turn on multi-purification.
5| | Purification/humidification button
Press the purification/humidification button to turn on the purification/ humidification feature.
6| | lock button
Press and hold the button lock button for 3 seconds to lock out button input.
7| | Current humidity button
Press the current humidity button to show the current humidity level on the status display.
Tips
– Plug the power plug into a socket before operating the purifier.
– When the purifier is turned on, it starts in auto mode by default.
Standard purification
Standard purification offers plenty of care for your space.
In normal flow mode, breeze is expelled from the purifier’s upper (central)
vent. You can select manual operation or the mode you want to use.
– To operate manually
Press the power button to turn on the purifier, and then press the air volume
button to select your desired air volume.
– To select a mode
Press the power button to turn on the purifier, and then press the mode button
to select your desired operating mode. AUTO CALM MAX
– Auto mode
Operates effectively by automatically adjusting the purifier’s air volume
(level 1 level 2 level 3) depending on the indoor pollution level detected by
the sensor. This is a convenient operating mode for most users.
| Pollution level 1| Pollution level 2, 3| Pollution level 4
---|---|---|---
Air volume| Level 1| Level 2| Level 3
– Calm mode
Minimizes air volume during purification and humidification/purification to
create a quiet, comfortable environment. This operating mode is quiet and
consumes less power.
- The air volume indicator is off during Calm mode.
– Max mode
In Max mode, the sensor’s sensitivity is changed to remove dust of relatively large sizes faster. In Max mode, automatic speed adjustment continues according to the air condition, and after 20 minutes, the device switches to Auto mode, so that it does not consume more power than necessary. This mode is effective after returning home or after ventilation. - Press the Speed button during operation in Max mode to exit Max mode and set the desired speed.
Humidification/purification
A feature that provides focused care for spaces where users are active.In
humidification/purification mode, a breeze is expelled from the purifier’s top
(front), front, and sides.
If water is put into the water tank during air purification and the water tank
is put in the purifier, it converts to humidification/purification.
Press the humidification/purification button after cleaning the water tray and
humidifying filter to operate in this mode.
Multi-purification
A feature that cares for every inch of the space where it’s used.
In multi-purification mode, a breeze is expelled from the purifier’s top,
front, and sides and the air volume stays low to create a comfortable air
current.
Humidifying filter drying
When the purifier is switched off or converted to a different mode while there
is still water in the water tank or water tray, a filter drying notification
is displayed and the humidifying filter drying feature operates.
- If the humidification feature is not in use and the water tank is not emptied, a notification sound tells the user to empty the water tank after 6 hours (notification repeated up to 8 times every 6 hours).
- Because the humidifying filter drying feature dries unused water in the tank, its operating time may vary depending on its surroundings.
- Air may be expelled from the front of the purifier while it is drying.
- Press the multi-purification button while in drying mode to change functions and press the multi-purification button once more to convert to standard purification mode.
ADJUST PARTICLE SENSOR
To adjust the particle sensor sensitivity
When you first turn on the purifier, the particle sensor is set to standard.
You can adjust the sensitivity as follows if the air quality LED stays at
severe even after the purifier runs for 2 hours or more with high pollution or
if the air quality LED stays at clean even if the pollution is high.
- Simultaneously press and hold the air volume button and mode button for at least 2 seconds while the purifier is operating.
- The currently set sensitivity is shown on the display.
- The default sensitivity is L1.
3. Press the air volume button to set sensor sensitivity as desired.
When sensor sensitivity is set, the following air volume indicators are illuminated on the display.Display| L0/Air volume 1| L1/Air volume 2| L2/Air volume 3
---|---|---|---
Sensitivity Level| Sensitive| Standard| Insensitive
4. Press and hold the air volume and mode buttons simultaneously for at least 2 seconds again to input your selected sensitivity and return to normal operation. - If the air volume button and mode button are not pressed for 10 seconds after selecting sensitivity, the selected sensitivity is automatically input.
HOW TO ADD WATER
Filling up the water tank
- Lift the water tank cover, then grasp the water tank handle and remove the water tank.
- Turn the water tank cap in a counterclockwise direction to detach.
- Put in water and turn the water tank cap in a clockwise direction until you hear a click as it locks.
Tips
– If you press the cap down too hard to tighten it, it may be damaged or not
fully closed and may leak water.
– When tightening the cap, hold its sides and turn it to lock it in place
Precautions when reinstalling the water tank
When inserting the cistern into the purifier, push it all the way in until you
hear a click. If the cistern is not completely installed, it may cause leaks
or faulty operation. If the water tank and cistern are not correctly
installed, a “refill water” notification is displayed on the front.
If you push the water tank and cistern all the way in so they are correctly
installed, the “refill water” notification will shut off and the purifier will
operate normally.
Tips
– It is best to fill the water tank with water all the way to the MAX mark.
– The water tank lasts approximately 12 hours at silent air volume and 4 hours
at L3 air volume, and it is best to check the amount of water remaining before
using the humidification feature.
– When reinstalling the water tank, hold the inner handle to ensure your
fingers are not caught.
HOW TO CLEAN
Tips
– Always unplug the power before cleaning.
– Do not use detergents containing organic solvents (solvents, thinners,
etc.), bleach, chlorine, or abrasives to clean.
– Do not immerse the purifier in water or sprinkle water on it.
Cleaning the particle sensor(clean every 2 months)
- Open the particle sensor cover.
Wet a cotton ball with a small amount of water and wipe the lenses (2), dust inlet, and vent, then wipe again with a dry cotton ball to remove moisture.
- If cleaning is not done regularly, the particle sensor may not work as well.
- The cleaning cycle differs depending on the purifier’s surroundings. Clean more often in dusty environments. 2. Clean the dust intake and vent with a soft brush or vacuum cleaner.
- Take care that dust does not fall inside the purifier while cleaning.
Cleaning the air intake and outlet (clean every 2 months)
Clean the air intake and outlet with a soft brush.
- Take care that dust does not fall inside the purifier while cleaning.
Cleaning the front cover
Remove the front cover from the purifier and then wipe away dust stuck to the
surface with a soft, dry cloth or soft brush.
- If there is severe contamination, use a damp cloth (do not use abrasives).
Cleaning the purifier itself (clean every 2-4 weeks)
Wipe with a soft, dry cloth.
- If there is severe contamination, use a damp cloth (do not use abrasives).
Cleaning the water tank (clean daily)
- Remove the water tank from the side of the purifier and then turn the water tank cover located at the bottom of the water tank in a counter-clockwise direction to open. If there is water left in the water tank, discard it before cleaning.
- Fill the water tank to about 1/3 and put in a small amount of neutral detergent. Turn the water tank cover in a clockwise direction to close. Hold the water tank with both hands as in the following picture and shake from left to right so all sides of the water tank can be washed.
- Turn the water tank cover in a counter-clockwise direction to open and discard the water mixed with detergent, then rinse well in running water.
- Do not excessively impact the water tank exterior. There is a risk of damage if there is excessive impact. This can cause water leaks.
- When tightening the cap, close it in a clockwise direction until you hear a click to lock it.
- If the water tank cap is not completely closed, it may cause leaks or faulty operation.
- After using a neutral detergent, wash well so no residue remains. Otherwise, performance may decrease. 4. Dry the water tank in a shady place until it is completely dry, then put it back in the purifier.
Cleaning the water tray (daily)
- Remove the water tank from the purifier and then open the front cover and pull the water tray forward to remove it.
- Pull the water tray to remove as in the picture. Be careful as water in the handle hole can get on your hands. 2. Carefully remove the humidifying filter from the water tray.
- When removing the humidifying filter, water absorbed by it may drain. Be careful.Soak the humidifying filter in lukewarm water (no hotter than 40 ) for at least 20 minutes, then use a cleaning brush to gently clean in running water.
- Depending on the environment, tap water may leave a white mineral residue on the humidifying filter as it dries. Clean in running water and dry.
- The accumulation period and properties of mineral residue may differ depending on the environment. 3. Remove the humidifying filter and water tray cover from the tank in that order and then wet a soft cloth or cleaning brush in neutral detergent and wipe the water tray under running water. Wipe away moisture from the water tray with a soft, dry cloth and dry it in a shady place.
FILTER REPLACEMENT
How to replace
-During filter assembly, be sure to check the front of the filters.
-Only use genuine Coway filters to keep the purifier at its optimal performance.
-Always unplug the power plug before replacing the filters.
How to discard
Used filters are household waste. Dispose of small quantities in local
government trash bags (for ordinary household waste) and ask your local
government how to dispose of large quantities.
Filter cleaning and replacement cycle
Filter | Cleaning/replacement time | Cleaning/replacement |
---|---|---|
Pre-filter | Once/2-4 weeks | Clean and wash |
Fine dust filter(Optional) | Once/4 months | Replace |
Green Max2 filter | Once / 12 months | Replace |
Humidifying filter | Once/week | Clean and wash |
Once/4 months | Replace |
- The filter replacement cycle is subject to change without prior notice due to the surroundings or regulations or for product upgrades and quality improvement.
Tips
– Always unplug the power before cleaning the filters.
– The pre-filter can be reused after removing dust and cleaning with water.
– If the pre-filter is not cleaned for a long time, the product performance
may decrease and problems may occur.
– Fine dust filter(Optional), Green Max2 filter cannot be reused after
cleaning.
Never clean the other filters with water.
Pre-filter (clean every 2-4 weeks)
- Hold the upper part of the front cover and pull to open.
- Push the pre-filter handle to take it out.
- Remove dust with water or a vacuum cleaner depending on the degree of contamination.
- Dry all moisture on the pre-filter before reinstalling it in the purifier. Put the front cover back on the purifier.
- When installing the pre-filter in the purifier, be sure to attach it exactly on the hook.
- Wash the pre-filter in running water or water with a neutral detergent dissolved in it (about 30 ) and then completely dry it in a shady place with a cross-breeze. If it is dried in direct sunlight or near a dryer, heater, or other heat-generating items, it may be warped and not work in the purifier.
How to replace air purifier filters
Check the front of the HEPA filter before replacing it.
- Use it only after removing the plastic packaging.
How to replace the humidifying filter
- Remove the water tank from the purifier and then open the front cover and pull the water tray forward to remove it.
- Carefully remove the humidifying filter so water doesn’t splash and replace it.
- Use it only after removing the plastic packaging.
TROUBLESHOOTING
The product may not operate correctly for trivial reasons or due to unfamiliar methods of use that are not product malfunctions. In such cases, the problem can be solved easily without the help of a service center if the following items are checked. If the problem is not resolved even after checking the following, please contact a service center.
Problem | Check | Possible Solutions |
---|---|---|
There is no breeze. | •Is the power plugged in? | The power plug must be plugged |
into a 220 V – 240 V- 50 Hz, 60 Hz socket.
•Is the entire display off?| Press the power button, then select your desired
feature.
•Is there a power failure?| After thepower comes back on, use the purifier.
•Is the water tank not fully in place?| Ensure the water tank is installed all
the way.
Air volume doesn’t change.| •Is the purifier operating manually?| Turn on your
desired operating mode.
•Is the purifier operating on calm mode?| Air volume is set at minimum during
calm mode.
There is considerably less air volume than when I first used the purifier.|
•Is it past time to clean or replace the filters?| Check your filter cleaning
and replacement cycle and clean or replace filters.
There’s a smell from the air vent.| •Is it past time to clean or replace the
filters?| Check your filter cleaning and replacement cycle and clean or
replace filters.
The pollution indicator
always shows the same color.| •Is there dust on the particle sensor lens?|
Clean theparticle sensor lens.
•Does the dust pollution level continuously appear high?| Set the particle
sensor sensitivity to insensitive or standard.
•Does the dust pollution level continuously appear low?| Set the particle
sensor sensitivity to sensitive or standard.
The air quality indicator is blinking.| •Request service.
If other functional defects occur| •Check the problem, then unplug the power
and contact or request service.
The refill water indicator is on.| •Is the water tank not fully nstalled?|
Ensure the water tank is installed all the way.
PRODUCT SPECIFICATIONS
Item | Air purifier & humidifier |
---|---|
Model Name | APMS-1020A |
Rated Voltage | 220 V – 240 V~ 50 Hz, 60 Hz |
Phase | Single-phase |
Power consumption | Purification: 58 W / humidification and purification: 36 W |
Product insulation grade | Class 2 device ![Icon](https://manuals.plus/wp- |
content/uploads/2022/05/Screenshot_3-305.png)
Dust collection method| Mechanical dust collection (Green Max2 filter)
Safety equipment| Power blocked when opening and closing the door
Installation location| For indoor use
Product size| 400 mm (width) x 225 mm (depth) x 720 mm (height)
Net weight| 12 kg
WARRANTY CARD OR WARRANTY LETTER
TWO YEAR LIMITED WARRANTY AIR PURIFIER APMS-1020A(“PRODUCT”)
Model:
Serial Number:
Customer Name:
Date of Purchase:
What This Warranty Covers:
Commencing with the date of purchase of the Product and continuing for a
period of Two years, if manufacturing defects in the Product cause the Product
to not operate properly for its intended use, then subject to the exclusions,
conditions, and limitations contained herein, COWAY at its sole option will
repair or replace the Product.
Decisions as to the extent of repair or replacement required will be made
solely by COWAY.
The remedy under this Warranty is available only for that portion of the
Product exhibiting defects at the time of the warranty claim. The replacement
Product as well as any remaining original Product will be warranted only for
the original two years warranty period. This limited warranty applies only to
Product used for an application specified by COWAY for the Product and applied
in strict accordance with COWAY published specifications in effect at the time
of application. IF PRODUCT IS USED FOR OTHER THAN ITS INTENDED PURPOSE, IT IS
SOLD AS IS AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
What This Warranty Does Not Cover:
This Warranty warrants that the Product will be free from manufacturing
defects which affect the ability of the Product to operate for its intended
use; it is not a warranty that the Product will never require repairs or to
undertake responsibilities, liabilities or obligations other than those
specifically identified in the preceding section. COWAY is not responsible or
liable for personal injury or property damage of any kind, even if arising
from a breach of this Warranty.
Limitations and Exclusions:
TO THE EXTENT PERMITTED BY APPLICABLE LAW, COWAY DISCLAIMS ANY OTHER WARRANTY
EXPRESS OR IMPLIED, THAN THAT PROVIDED FOR HEREIN. THIS WARRANTY IS IN LIEU OF
AND EXCLUDES ALL OTHER WARRANTIES, GUARANTEES, CONDITIONS AND REPRESENTATIONS,
EXPRESS OR IMPLIED, ORAL OR WRITTEN, STATUTORY OR OTHERWISE, INCLUDING BUT NOT
LIMITED
TO ANY IMPLIED CONDITIONS OR WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE OF THE COWAY PRODUCT.
SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO
THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
COWAY DOES NOT AUTHORIZE ANY PERSON INCLUDING ITS REPRESENTATIVES, TO MAKE ANY
REPRESENTATION OR TO OFFER ANY WARRANTY, CONDITION OR GUARANTY IN RESPECT OF
THE PRODUCT OTHER THAN THIS WARRANTY. THIS LIMITED WARRANTY SHALL BE THE
OWNER’S SOLE AND EXCLUSIVE REMEDY AGAINST COWAY AND COWAY SHALL NOT BE LIABLE
FOR ANY CONSEQUENTIAL, EXEMPLARY, SPECIAL, INCIDENTAL OR OTHER AMAGES
INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, AND LOSS OF USE. INCIDENTAL,
CONSEQUENTIAL AND EXEMPLARY DAMAGES SHALL NOT BE RECOVERABLE EVEN IF THE
REMEDIES OR THE ACTIONS PROVIDED FOR IN THIS WARRANTY FAIL OF THEIR ESSENTIAL
PURPOSE. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO
YOU. COWAY SHALL NOT BE LIABLE FOR ANY DAMAGES WHICH ARE BASED UPON
NEGLIGENCE, BREACH OF WARRANTY, STRICT LIABILITY OR ANY OTHER LEGAL THEORY OF
LIABILITY OTHER THAN THE EXCLUSIVE LIABILITY SET FORTH IN THIS WARRANTY.
Limitations on Implied Warranties:
Any implied warranty of merchantability or fitness for a particular purpose or
use, shall be limited to the duration of the foregoing express written
warranty.
Conditions of Warranty:
COWAY’s continuing liability under this Warranty is conditioned upon the
following:
a) The defect or damage is not causedby or is the result of: abnormal use or
conditions; improper storage, unauthorized modifications or repair; misuse,
neglect, accident, alteration, improper installation or other acts that are
not the fault of Coway or the manufacturer of the product or that are not
covered by the manufacturer’s warranty;
b) The Product has not been altered, modified or repaired without prior
written approval of COWAY;
c) The OWNER has notified COWAY in writing of any failure of the Product
covered by this
Warranty within thirty (30) days following such failure;
d) There has been no misuse, abuse or negligence with respect to the Product
on the part of the OWNER.
Waiver:
COWAY’s failure at any time to enforce or rely upon any of the terms or
conditions stated herein shall not be construed to be a waiver of its rights
hereunder.
Obtaining Warranty Service and OWNER’S Duties:
If the Product fails to operate for its intended purpose, then notify COWAY or
its Representative Agency, within 48 hours or within the next business day
after discovery of any defect in the Product. The OWNER must give written
notice to COWAY no later than
thirty (30) days after a defect is discovered or should by reasonable
diligence have been discovered. Claims under this Warranty will require proof
of purchase by the OWNER
COWAY EU
Tel. : UK – London : +44 2032807197
GERMANY – Hamburg : +49 4087406758
FRANCE – Paris : +33 170120004
ITALY – Milan : +39 0236003045
SPAIN – Madrid : +34 911234181
Mail : info_eu@coway.com
Web : de.coway.com
COWAY
Add : COWAY Co., Ltd. 136-23, Yugumagoksa-ro, Yugu-eup,
Gongju-si, Chungcheongnam-do, Korea
Tel. : Korea-Seoul : +82-1588-5200
SWEDEN
Add : Albion Nordic AB Traktorgatan 2 745 37
Enköping Sweden
Tel. : +46 171 66 33 00
Mail : info@albionnordic.com
Web : www.albionnordic.com
001
9240643
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>