coway AP-1216L Tower True Hepa Air Purifier Owner’s Manual
- June 16, 2024
- Coway
Table of Contents
coway AP-1216L Tower True Hepa Air Purifier Owner’s Manual
FEATURES
Excellent air purification performance
HEPA filter is capable of trapping airborne allergens and contaminants down to
0.3 microns. It reduces airborne bacteria, mold spores and particles that
carry viruses. The unit’s filter system has been optimized to remove indoor
pollutants fast and effectively.
Air quality indicator
It shows the indoor air pollution level measured by the dust sensor.
The color of air quality indicator changes according to the indoor air
pollution level in real time (Blue → Purple → Red).
Filter replacement indicator
The product checks the filter replacement cycle and turns on the relevant
indicator, improving customer convenience with regard to filter replacement.
Timer
The timer feature allows you to control how long you want the air purifier to
run before automatically powering off.
SAFETY PRECAUTIONS
DANGER : Failing to follow the precautions below may result in serious injury
or even death.
- Do not use a damaged power plug or loose electric outlet.
- Please connect the power plug to a dedicated grounded electrical outlet for 120 V, 60 Hz.
- Do not move the product by pulling only the power cord.
- Do not handle the power plug with wet hands.
- Do not forcefully bend the power cord or place it under a heavy object to prevent it from being damaged or deformed.
- Do not repeatedly connect and disconnect the power plug.
- If the electrical outlet is wet, carefully unplug the product and let the electrical outlet dry completely before subsequent use.
- Make sure to unplug the product before repairing, inspecting or replacing a part.
- Remove any dust or water from the power plug.
- Do not plug the product into an electrical outlet or power strip that is being used by several other appliances. Use an electrical outlet dedicated to the product.
- Unplug the system if it is not used for a long time.
- Do not attempt to repair or modify the power cord yourself.
- If the power cord is damaged, do not replace the cord yourself. Call a service center to have it replaced.
- Do not install the product near a heating device.
- Do not install the product in locations exposed to moisture or water (rainwater).
- Do not use the product in areas where flammable gases or combustible materials are used or stored.
- Do not insert sharp objects such as a gimlet into the Air quality sensor.
- If the product produces a strange noise, burning smell or smoke, unplug it from the electrical outlet immediately and call our service center.
- Never place the product in water.
- Do not spray any flammable materials such as insecticides or air fragrances near or into the air inlet.
- Do not disassemble, repair, or modify the product at your own discretion.
- Do not place any containers with water, medicine, food, metallic objects or flammable material on top of the product.
- Unplug the system before cleaning it.
- Do not clean by spraying water directly and do not clean the product using benzene or thinner.
- Use the product for home or business use according to the model.
- Do not use the air purifier in a factory or industrial setting where machine oil may be present in the air.
- Do not run cord under carpeting. Do not cover with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
- This product contains a chemical known to the State of Califonia to cause cancer and birth defects or other reproductive harm. (California law requires this warning to be given to customers in the State of California)
- This product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume (ppmv) in a 24-hour period. The Health Canada Guideline 2010 recommends that the maximum exposure limit, based on an averaging time of 8 hours, is 0.020 ppmv or less when tested in a sealed, controlled room approximately 30 m³.
WARNING : Failing to follow the precautions below may result in considerable
physical injury or property damage.
- The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
- Do not insert fingers or foreign objects into the air inlet or outlet.
- Do not let children hang on to the product or climb on it.
- When removing the front cover, exercise caution that a part of your body or any kind of object does not become stuck in the top part of the product.
- This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
- Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Arrange cord away from traffic area and where it will not be tripped over.
CAUTION : Failing to follow the precautions below may result in slight
physical injury or property damage.
- Do not install the product on a sloped surface.
- Do not apply force or impact to the product.
- When the product is in use, maintain a distance of at least 20 cm from the walls or adjacent objects and 30 to 60 cm above the product.
- Install the product so that no obstacles block the circulation of air around the product.
- Install the air purifier away from strong artificial lighting or direct sunlight.
- Install the air purifier at least 2 m away from electronic appliances such as a TV.
- Do not install the air purifier in a location exposed to direct sunlight.
- Replace the filters according to the filter replacement cycles.
- Clean the Pre-filter with water regularly and dry it completely before use.
- Suitable for use with solid-state speed controls.
- Cleaning and user-maintenance, such as lubrication, may result in fire, electric shock, or injury to persons.
- Unplug or disconnect the appliance from the power supply before servicing
READ AND SAVE THESE INSTRUCTIONS
PARTS NAME
Front / Rear
-
Operation / Indication part.
-
Air quality indicator
-
Air quality sensor
-
Front cover
-
Handle
Air outlet -
Power cord
Operation / Indication part
Air quality indicator
Clean : Blue
Polluted : Purple
Highly polluted: Red
The quality level of the indoor air can be determined by the color of the round lamp located at the top of the air purifier.
PARTS NAME
-
Power Button
Use this button to turn the air purifier on or off.- To power off, press and hold the power button for 2~3 second.
-
Ionizer button
Use this button to turn the ionizer on or off. -
Speed Button
- Use this button to adjust the fan speed.
- Available settings for the fan speed are
- Auto → 1 → 2 → 3
-
Timer Button
Use this button to turn off the air purifier after a predetermined period of time. Available timer settings are 1H, 4H, 8H and 12H. -
Light Button
Use this button to turn the light on or off. -
Filter Reset Button
When the filter replacement indicator Is turned on, replace the relevant filter and press the RESET button. -
Ionizer indicator
It shows whether the ionizer is turned on or off. -
Speed indicator
It shows the current fan speed. Each indicator is turned on as per its airflow speed. -
Timer indicator
It shows the current time setting for air purification. Each indicator is turned on as per its set timer -
Light indicator
It shows whether the light is turned on or off. -
Filter replacement indicator
Replace the filter when this indicator is on. Refer to filter replacement cycle for each filter. -
Air quality indicator
It displays the current pollution level of the room.
AIR PURIFICATION PROCESS
Air purification system
-
Pre-filter
It removes relatively large dust and mold, human hair, pet hair, and so on. -
Odor filter
Odor Filter is particularly effective at trapping odor and harmful gas to keep your place fresh and odor-free. -
HEPA filter
The high-performance composite HEPA filter effectively removes fine dust and cigarette smoke up to 99.97%. It reduces airborne bacteria, mold spores and particles
PREPARATIONS
Please check before use!
The product is for 120 V~, 60 Hz only.
Make sure to connect the power plug to a grounded electric outlet (120 V~, 60
Hz) dedicated to the product.
How to Install Filter
Tips
- Make sure to remove each filter’s plastic bag before installing filters.
- The product is for household use. Use the product indoors only.
- When the product is not in use, remove the power plug from the electric outlet.
- When installing filters, check that the front side of filters is in the correct direction.
- Order of filters : Pre-filter → Odor filter → HEPA filter
-
Open the front cover.
- Open the front cover by pulling the upper part of it.
- Open the front cover by pulling the upper part of it.
-
Take out used filters and remove the plastic bag from the new filters.
- Remove the plastic packing of the filters and install the filters by proper order.
- Remove the plastic packing of the filters and install the filters by proper order.
-
Install the filter as following order : HEPA filter → Odor filter
Pre-filter- When you install Pre-filter, make sure to push the grip to install it firmly.
- When you install Pre-filter, make sure to push the grip to install it firmly.
HOW TO USE
Tips
- Before operating the product, connect the power plug to the electric outlet.
- When the air purifier is turned on, it automatically operates in auto mode.
Manual & Auto mode
Press the power button and then select the speed of the fan by pressing the
speed button.
Auto → 1 → 2→3
Auto mode
Automatically optimizes the speed setting 1 through 3 based on the level of
indoor air quality detected by dust sensor.
This mode is recommended for general users.
Timer activation/deactivation
The Timer feature instructs the air purifier to automatically power off after
1, 4, 8 or 12 hours.
- To deactivate the timer, press and hold the Timer button until the indicator is no longer lit.
- 1H → 4H → 8H → 12H→Timer off
ADJUST AIR QUALITY SENSOR
When the product is shipped out, the air quality sensor is set to standard sensitivity. If the pollution level stays at the highest level after 2 hours of operation or stays at the lowest level for more than 1 hour when the air does not seem clean, users can adjust the sensitivity of the air quality sensor as follows.
-
While the air purifier is on, press the airflow speed button and ionizer button for 2 seconds.
-
The speed indicator will flash at 1.0 second intervals with beep.
The speed indicator blinks to show the sensor sensitivity. -
Adjust the sensitivity by pressing the speed button.
The speed indicator blinks to show the sensor sensitivity
Speed step 1 | Speed step 2 | Speed step 3 |
---|---|---|
High | Standard | Low |
High sensitivity: If the air purifier indicates a pollution level of 1 for
longer than one hour when the actual pollution level is higher.
Low sensitivity: If the air purifier continues to indicate the highest
pollution level even after running the air purifier for more than two hours.
-
Press the airflow speed button and ionizer button for 2 seconds.
The air purifier will then resume normal operations.- The new setting will also be applied if no button is input for 10 seconds.
CLEANING METHOD
Tips
- Always unplug the air purifier before cleaning the product.
- Do not use detergents that contain organic solvents (solvent, thinner, etc), bleach, chlorine, or abrasives.
- Do not put the air purifier in water or spray water directly on it.
Cleaning the air quality sensor (every 2 months)
-
Open the air quality sensor cover on the right-hand side of the product.
Clean the air inlet and outlet vent and then the air quality sensor with a soft brush or vacuum cleaner.
-
Wet a cotton swab lightly and clean the lens, dust inlet, and dust outlet. Clean them with a dry cotton swab to remove remaining moisture.
- Without regular cleaning, the performance of the air quality sensor deteriorates.
- The cleaning cycle differs depending on the operation environment. When using the product in a dusty environment, clean the sensor more often.
Cleaning the air inlet and outlet (every 2 months)
Clean the air inlet and outlet with a soft brush.
- Exercise caution not to have dust fall inside the air purifier.
- If covered in dust, run the air purifier in manual mode for 10 minutes to blow the dust off the vent. You may then continue with normal use.
Cleaning the front cover
Separate the front cover from the product and remove the dust attached to the
surface with a soft dry brush or cloth.
Use lightly wet cloth if the contamination is serious but do not use abrasives.
Cleaning the product body (every 2 ~ 4 weeks)
Use dry, soft cloth to clean the product.
Use lightly wet cloth if the contamination is serious but do not use
abrasives.
CLEANING METHOD
Tips
- Always unplug the product before cleaning the filter.
- The pre-filter is reusable by removing dust or cleaning it with water.
- If the pre-filter is not cleaned for a long time, the product performance may deteriorate.
- Odor filter and HEPA filter cannot be cleaned and reused. Never clean them with water.
Cleaning the pre-filter (every 2 ~ 4 weeks)
-
Open the front cover by pulling out the top part of it.
-
Press down on the top clip of the pre-filter and pull it out.
- To prevent dust from falling off, remove the filter carefully without exerting a shock.
- To prevent dust from falling off, remove the filter carefully without exerting a shock.
-
Clean the pre-filer with a vacuum cleaner or with water depending on the level of contamination.
-
Install the pre-filter after removing the moisture completely. Fit the front cover back to the product.
- When refitting the pre-filter to the product, fit it in the hook correctly.
- When refitting the pre-filter to the product, fit it in the hook correctly.
FILTER REPLACEMENT
Tips
- Check that the ‘front’ side of filters are in the correct direction.
- To maintain optimal performance of the product, use original Coway filters.
- Always unplug the air purifier before replacing filters.
Filter cleaning and replacement cycles
Filter | Cycles | Method |
---|---|---|
Pre-filter | Every 2~4 weeks | Cleaning |
Odor filter | Every 6 months | Replacement |
HEPA filter | Every 1 year | Replacement |
- Each service life is based on 8-hour use in maximum air speed.
- The recommended filter replacement cycles may differ depending on the operating environment
Resetting the filter replacement indicator
-
Reset indicator blinks when the filter needs to be replaced.
-
Odor LED : Odor Filter HEPA LED : HEPA filter
-
The pollution level indicator will not turn on if the filter replacement indicator is activated.
-
After replacing filter, push the Reset button for 2 seconds.
Forcible reset mode
When you have replaced a filter before the filter replacement cycle is
reached, you can forcibly reset the filter replacement cycle back to the
factory default setting.
-
When the reset function is not activated, press and hold the reset button for 2 seconds.
-
Press the reset button to select the desired filter to forcibly reset.
Press once : Odor LED (Odor Filter)
Press twice : HEPA LED (HEPA filter) -
After you select the filter to reset, press and hold the reset button for 2 seconds. And then,the accumulated time in electronic time counter is erased.
-
If there is no input for 5 seconds in forcible reset mode, the reset mode is cancelled
TROUBLESHOOTING
The air purifier may operate abnormally not because of the product malfunction but because of minor causes or the fact that the user is not familiar with the product use. In such a case, problems can be solved easily even without the help from the service center just by checking the following. If the problem still persists after you check the following, contact the service center.
Problems | Check | Possible solutions |
---|---|---|
No air is blowing. |
- Is the power cord connected?
| Connect the power cord to an electric outlet for 120 V~, 60 Hz.
- Is the display part all turned off?
| Press the power button and then select the desired function.
- Isn’t the power gone out?
| Use the air purifier after the power comes back on.
- Is the front cover closed?
| Close the front cover properly.
The airflow speed does not change.|
- Isn’t it in manual?
| Set the desired operating mode.
The airflow speed is significantly weaker than before.|
- Isn’t the filter cleaning or replacement time passed?
| Check the filter cleaning and replacement cycles and then clean/replace the
filter(s) if necessary.
A bad smell comes out of the air outlet.|
- Isn’t the filter cleaning or replacement time passed?
| Check the filter cleaning and replacement cycles and then clean/replace the
filter(s) if necessary.
**** The color of the pollution level indicator always stays the same.|
- Isn’t there dust on the pollution sensor’s lens?
| Clean the lens of the pollution sensor.
- Does the pollution level keep indicating a high level?
| Adjust the sensitivity of the pollution sensor to Insensitive or standard.
- Does the pollution level keep indicating a low level?
| Adjust the sensitivity of the pollution sensor to sensitive or standard.
When other functional problems are detected.|
- Check the symptoms, unplug the product, and ask service center.
SPECIFICATIONS
Product specification | Air Purifier |
---|---|
Model | AP-1216L |
Rated voltage | 120 V~, 60 Hz |
Phase | Single phase |
Power consumption | 55 W |
Product insulation grade | Grade 2 device |
Dust collection method | Mechanical dust collection method (HEPA filter) |
Safety feature | Fan motor is shut down when front cover is open. |
Installation place | Indoor use |
Maximum volume of air | 268.39 ft3/min |
Size | 10.83inch(W)X10.63inch(D)X32.88inch(H) |
Weight | 14.3lbs |
Specifications are subject to change without notice.
WARRANTY CARD OR WARRANTY LETTER
THREE YEAR LIMITED WARRANTY
- Model:
- Serial Number:
- Customer Name: (“OWNER”)
- Date of Purchase:
3-Year Manufacturer’s Limited Warranty
Subject to the terms and conditions of this limited warranty, the Manufacturer warrants this product to be free from defects in material or workmanship for a period of three years from the date of its original retail purchase.
What This Limited Warranty Covers
This warranty covers any defects or malfunctions in the motor and/or electronic parts.
How Long Is The Coverage?
This warranty is for a period of three years from the date of its original retail purchase. This warranty is not transferable and coverage terminates if you sell or otherwise transfer the product.
What Will Manufacturer Do?
Manufacturer will, at its option, repair or replace the defective or malfunctioning part at no charge. The repaired or replaced part will be covered by the remaining period of the original warranty.
What Does This Warranty Not Cover?
This limited warranty excludes any and all replacement filter parts and any problem arising from (a) abuse, misuse, accident, improper operation or maintenance, (b) an act of God (such as a flood, hurricane, tornado, or other weather-related event), or (c) use of any parts from another manufacturer.
To the extent permissible by applicable law, consequential and incidental damages are not recoverable under this limited warranty and this warranty shall be deemed to supersede and negate any and all other warranties, express or implied, and all other obligations or liabilities of the Manufacturer and authorized retailer, including any implied warranties of merchantability and fitness for a particular purpose. Note, some states do not allow the exclusion or limitation of incidental or consequential damages, so the prior sentence may not apply to you.
How Do You Get Service?
In order to be eligible for service under this warranty, proof of purchase
(original receipt) must be made available to the Manufacturer or its service
representative for all warranty claims. Please call
1-888-960-5747 to speak with an
authorized representative of the Manufacturer regarding this warranty.
Your Rights Under State Law
This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.
Contact us
Coway welcomes feedback from our customers.
If you have a question, concern or comment, please call our Customer Relations
Department toll-free at 1-888-960-5747
OR send an email to support@coway-usa.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>