moes Zigbee WiFi Radiator Actuator User Manual
- June 8, 2024
- MOES
Table of Contents
moes Zigbee WiFi Radiator Actuator
Zigbee WIFI Radiator Actuator User Manual
Many thanks for your selection of our products and services, and also for your trust and support of us.
Search for “Smart Life” Download the Wifi App with the following icon
Note: Cellphone and gateway must connect under the same WIFI router.
- Add your gateway to the App, then add your radiator actuator to your gateway in the App.
- After the ZigBee gateway is configured, enter the gateway to add sub-devices, and wait for the actuator to be powered on and the system self-check to be completed. long press access to set, short press to choose an icon, short press to enter network connected mode, then long press , flashing access network connected mode.
- Please refer to the gateway manual for Zigbee gateway configuration.
Product Specifications
- Power: 2* AA alkaline batteries
- Display accuracy:: 0.5℃
- Probe sensor:: NTC(10k)1%
- Maximum route :4.5mm
- The default range of temperature adjustment: 5~35°C
- Working environment temperature: :-10~60°C
- Insulating condition: 0-50℃
- Running program: Set per 1 week as a cycle Size(mm): 53*89.5mm
- Range of temperature display:: 1~70°C
- Maximum current: 90mA
- Thread size: M30*1.5
Displays & Buttons
No: | keys | Represent |
---|---|---|
D | 1.Short press to switch manual mode and auto mode 2.Long press to access |
setting interface
3.Confirm key
E| | 1. Decrease key
2. Long press 3s to lock/unlock keys
F| | 1. Increase Key;
2. Long press 3s access Boost function setting, Press any key during operation
to exit this function and return to the original working mode
Installation and initial commissioning
After power on, the screen will show all for 3 seconds.
Time setting
Malfunction
Error Code | Description |
---|---|
E1 | Motor fault |
E2 | Sensor fault |
Flashing show low battery |
Special Function description
Holiday mode: press 3s access to the setting interface, short press to choose holiday mode then short press enter temperature setting, short press s etting days setting, press to adjust the value, under holiday mode, short press to exit holiday mode. Open Windows Function: 1. The actuator turns off the window opening function by default, if you need to use it, you can turn it on in the advanced option A2 setting [reset when changing the battery] When the actuator detects that the indoor temperature drops quickly to the valve closed setting value (adjustment range: 5℃-25℃), the valve will be closed for 15 minutes (adjustment range: 5-60 minutes), and it will be closed after the window opening function is completed. Return to the original operating mode, but the valve will be fully opened.
Programming mode setting
Press about 3s access to the setting interface, short press switch to, short
press access to programming, and short press to choose which item you want,
First set the auto mode to 5 means 5+2 days, 6 means 6+1 days, 7 means 7
days), after press to access to hours setting, Short press access to
temperature setting. press or to adjust value.
press to access to first periof minute setting, press or to adjust value,
press access to working days first period temperature setting, press or to
adjust value, press to set second time period,third time period…… from working
day to holiday,
After setting, do not operate the button for 10 seconds, the setting
parameters will be automatically saved and the normal working interface will
be returned.
period | Default period | Default temperature |
---|---|---|
1 | 6:00-8:00 | 20℃ |
2 | 8:00-11:30 | 15℃ |
3 | 11:30-12:30 | 15℃ |
4 | 12:30-17:30 | 15℃ |
5 | 17:30-22:00 | 20℃ |
6 | 22:00-6:00 | 15℃ |
Advanced options
Press about 3-5s to access to setting interface, short press until flashing, press access to advanced options, press or to adjust value, after finish setting every time, short press to set next option, after finishing all ,don’t operate, after 10s it will automatically save and exit.
No | Item | Setting parameters | default |
---|---|---|---|
A1 | Measuring temperature |
correction
| -9-+9°C| 1°C accuracy correction
A2
|
Window ventilation function: Window temperature and window function operating time
| 1:display means close window ventilation function close,press
key display 5°C means this function open(tem- perature setting range: 5-25°C)
2:operating
time:5-60min(a f ter open function, press change setting)
|
1.default of power on is means close
A3
| Automatic lock if no operation more than 10 minutes|
0:close 1:open
|
0
---|---|---|---
A4| The minimum limit of the setting temperature| 1-15°C| 5°C
A5| The maximum limit of the setting temperature| 16-70°C| 35°C
A6
|
BOOST mode operating time
|
100s-900s , Steps of 100 seconds
|
300 Seconds
A7
|
Check valve opening
| 0-99
99 mean valve open 100%
5 mean valve open 5%
|
A8| Heating start/stop Temperature hysteresis| 0.5-1.5| 1
A9| Display mode| 0:vertical display 1:horizontal display| 0
AA| Control type of valve| 0: PID 1:ON/OFF| 0
AB
|
Reset
|
Display 88, using or to change to 00, press to reset, The screen will be fully displayed for 2 seconds.
|
Thank you for your support and purchase at we Moes,we are always here for your
complete satisfaction,just feel free to share your great shopping experience
with us.
If you have any other need,please do not hesitate to contact us first,we will
try to meet your demand.
-
FoLow Us
-
f@moessmart
-
moes
-
@moes_smart
-
@moes_smart
-
@moes_smart
-
moes.net
-
WENZHOU NOVA NEW ENERGY CO.,LTD
-
Address: Power Science and Technology Innovation Center,
-
NO.238, Wei 11 Road, Yueqing Economic Development Zone,
-
Yueqing, Zhejiang, China
-
Tel:+86-577-57186815
-
Email: service@moeshouse.com
-
EGRAMZLAB GmbH
-
Laubenhof 23, 45326 Essen
-
Made In China
Documents / Resources
| moes
Zigbee WiFi Radiator
Actuator
[pdf] User Manual
Zigbee WiFi Radiator Actuator, Zigbee Radiator Actuator, WiFi Radiator
Actuator, Radiator Actuator, Radiator, Actuator
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>