Ventair VTMSENSOR Exhaust Fan Motion Sensor Instruction Manual

June 3, 2024
ventair

Ventair VTMSENSOR Exhaust Fan Motion SeVentair VTMSENSOR Exhaust Fan
Motion Sensor logonsor logo

Ventair VTMSENSOR Exhaust Fan Motion Sensor

Ventair VTMSENSOR Exhaust Fan Motion Sensor product

INSTALLATION AND WIRING

THIS PRODUCT MUST BE INSTALLED BY A LICENSED ELECTRICAL. TRUN OFF ALL POWER BY REMOVING POWER FUSE OR TURNING OFF CIRCUIT BREAKER

CAUTION

  • This product should be Installed in accordance with a Circuit Breaker(250V AC, 1 OA) type C according to EN30898-1
  • Do not mount on conductive surfaces
  • Do not open the enclosure frequently
  • Turn off all power by removing power fuse of turning off circuit breaker
  • A high “In-rush current” may occur when bulbs of certain brands are burnt
  • Which might damage the unit permanently
Selecting a Location

Since the sensor responds to temperature changes, please avoid the following conditions:

  • Do not aim the sensor towards lights of any kind.
  • Avoid directing the sensor towards areas or objects whose surfaces are highly reflective or are subject to rapid temperature change. Such as pools.
  • Avoid mounting the sensor near heat sources such as heating vents air conditioners. Dryer vents or lights.
  • Avoid aiming the sensor toward objects which may move in the wind such as curtains.Ventair VTMSENSOR Exhaust Fan Motion Sensor 01

Dimensions

  • Detector: 38.78X76.23X3R2mm
  • Power Box: 19.29X149.44X29′.41 mmVentair VTMSENSOR Exhaust Fan Motion Sensor 02

Application

  • OS451Acan be wide1ly used in offices ,conference rooms, hotels, lavatoriesTetc.
  • The optimum height or 2.5m is sug1g1es’led while lns·1all1in9 1 thus the detection rage can reach up to a circular of 6m diameter.

Please refer to following pattern at different mounting heightsVentair
VTMSENSOR Exhaust Fan Motion Sensor 03 Detection Pattern

  • Detection Area
  • Superimposed Detection Area
  • Detector

The deletion area at height of 2.SmVentair VTMSENSOR Exhaust Fan Motion
Sensor 04The deletion area at height of 4m DO NOT USE WITH DIMMERS.
Read entire instruction manual before proceeding.
All wiring should comply with local electrical codes will require a licensed electrician.
Note:
To ensure wiring is correct. Please recheck carefully after wiring Ventair VTMSENSOR Exhaust Fan Motion Sensor 06Note :
The thickness of ceiling board for installation can be 5-20mm(refer FIG.9).

Installation procedure

  • To install the sensor, drill a hole in the ceiling with a diameter of 32mm wide And keep the power cable outside the hole once drilled.

  • Strip off 6-8mm of Cable sheathing with toll.
    Ventair VTMSENSOR Exhaust Fan Motion Sensor 07

  • Unscrew protective cover on power box with screw driver.

  • Connect the power box terminal with RJ 11,the cover up the cable cover and screw it tightly.Ventair VTMSENSOR Exhaust Fan Motion Sensor 08

  • Refer to wiring diagram to connect cables, then cover up the cable cover and screw it tightly

  • After arranging all wires,insert the power box into ceiling through the drilled holeVentair VTMSENSOR Exhaust Fan Motion Sensor 10

  • Put detector’s two spring clips into the drilled hole, then insert the detector upwardsVentair VTMSENSOR Exhaust Fan Motion Sensor 11

  • Restore the power supply.

OPERATION

PULL OUT THE DETECTOR HEAD
  • Prize up the detector bead at the neck with a screwdriver
  • Pull out the detector slightly until the knobs are visibleVentair VTMSENSOR Exhaust Fan Motion Sensor 12
  • Push the detector head to normal position upwards after knob setting Completed
METER.TIME KNOB SETTING

Follow the marked values to adjust Meter. Time knobs according to User’s desiresVentair VTMSENSOR Exhaust Fan Motion Sensor 14

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ventair User Manuals

Related Manuals